Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 141

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DS1/T1 CPE Loopback Jack 
119 Loopback Testing with a Smart Jack 
9
5. End  the test. Enter 
test DS1-loop 
location end cpe-loopback-jack-test
6. Wait ab out 30 sec ond s for the DS1 to reframe on the inc oming  sig nal and 
c lear DS1 fac ility alarms. Condition Solution
The value of the Bit-error count
 field  is 
g reater than 1Rep lac e the ICSU, and  retest.
The value of the Bit-error count
 field is...

Page 142

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DS1/T1 CPE Loopback Jack 
120 Loopback Testing with a Smart Jack 
9
Restoring DS1 administration
1. At the manag ement terminal, op en the DS1 ad ministration form. Enter 
change DS1 
UUCSS
where UU is the c abinet numb er, C is the  c arrier number, and  SS is the 
slot number of the DS1 b oard .
2. Chang e to p ag e 2 of the DS1 ad ministration form. 
3. Change the value of the TX LBO
 field  to the orig...

Page 143

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DS1/T1 CPE Loopback Jack 
121 Loopback Testing with a Smart Jack 
9
NOTE:
This test c annot isolate the p roblem if there are p roblems in 
the wiring  b etween the far-end CO and  the far-end  ICSU. You 
must c oord inate this test with the DS1 servic e p rovider. 
1. From the manag ement terminal,  enter 
test DS1-loop 
UUCSS far-csu-loopback-test-begin
 
where 
UU is the c abinet numb er,C is the...

Page 144

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DS1/T1 CPE Loopback Jack 
122 Loopback Testing with a Smart Jack 
9
Figure 35. Network Interface at Extended Demarcation Point (Smart Jack Inaccessible)1. Sp an sec tion 1
2. Sp an sec tion 2
3. Sp an sec tion 3
4. 120A2 (or later) ICSU
5. RJ-48 to network interfac e (up  to 1000 ft 
[305 m] )6. Loop b ac k jac k
7. Dumb  b loc k (extend ed  d emarc ation)
8. Network interfac e smart jac k
9. Interfac e...

Page 145

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DS1/T1 CPE Loopback Jack 
123 Loopback Testing Without a Smart Jack 
9
Figure 36. Network Interface at Extended Demarcation Point (Smart Jack Accessible)
Loopback Testing Without a Smart 
Jack
When the loop b ac k jac k is ad ded  to a span that d oes not c ontain a smart jac k, 
the sp an is d ivid ed  into 2 sec tions: from the ICSU to the loop b ac k jac k and  from 
the loop b ac k jac k to the c...

Page 146

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DS1/T1 CPE Loopback Jack 
124 Loopback Testing Without a Smart Jack 
9
Figure 37. Network Interface at “Dumb” Block1. Sp an sec tion 1
2. Sp an sec tion 2
3. 120A2 (or later) ICSU
4. RJ-48 to network interfac e (up to 1000 ft [ 305 m] )5. Loopback jack
6. Dumb b loc k (d emarc ation p oint)
7. Interfac e termination or fib er 
multiplexer (MUX)
8. Central office 

Page 147

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DS1/T1 CPE Loopback Jack 
125 Loopback Testing Without a Smart Jack 
9
Figure 38. Network Interface at “Dumb” Block with Repeater Line to Fiber MUX
You are resp onsib le for find ing  and  c orrec ting  p rob lems in the c ustomer wiring  
(sec tion 1 and  the loop b ac k c ab le p ortion of sec tion 2). The DS1 servic e p rovid er 
is resp onsib le for find ing  and  c orrec ting  p rob lems in the...

Page 148

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DS1/T1 CPE Loopback Jack 
126 Loopback Testing Without a Smart Jack 
9
n
The far-end  ICSU’s line loop b ac k. Ac tivate this test at the 
manag ement terminal b y entering  test DS1-loop 
location far-csu-
loopback-test-begin
. Terminate this test b y entering  test DS1-loop 
location end-loopback/span-test
. Bit error c ounts are examined  
as desc rib ed  in the “ DS1 Sp an Test”  sec tion. This test...

Page 149

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DS1/T1 CPE Loopback Jack 
127 Loopback Testing Without a Smart Jack 
9
loop b ac k on the “ p rob lem”  DS1 fac ility, ac tivate it after a suc c essful 
loop b ac k jac k test, and  use it to isolate p rob lems to the wiring  b etween 
the loop b ac k jac k and the MUX.
2. Be aware that there are installations that use rep eatered  metallic  lines 
b etween the MUX and  the “ d umb ”  b loc k. These lines...

Page 150

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DS1/T1 CPE Loopback Jack 
128 Loopback Testing Without a Smart Jack 