Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 171
DEFINITY INADS 149 14 DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 14 DEFINITY INADS The DEFINITY ECS Initialization and Administration System (INADS) p rovid es analog loop bac k c onnec tions and PARTNERĀ® c onnec tions for remote alarming and maintenanc e when d irec t c onnec tion to the p ub lic network is not p ossib le. NOTE: These instruc tions are for DEFINITY ECS Release 7r or later systems using the TN1648/B system ac c...
Page 172
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY INADS 150 14 Figure 45. Analog Loopback Connections R8r Installing INADS Analog Loopback on a High- Reliability System Be su re t o p la c e t h e TN 1 6 4 8 B SYSAM c irc u i t p a c ks i n d iff e re n t c a b i n e t s o r p roc essor c arriers. Also b e sure to p lac e the analog line c irc uit p ac ks in the same c ab inets or c arriers as the TN1648 c irc uit p ac ks. 1....
Page 173
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY INADS 151 14 Administering DEFINITY ECS for INADS NOTE: Ad d 2 p auses in front of the d ial string when using c ut-throug h trunks. Pauses are not required if using ARS. 1. Type change system-parameters maintenance and press En t e r. 2. For hig h reliab ility systems, in the see interchange: field, type daily and p ress En t e r. This is d one in c ase 1 of the c onnec tions b...
Page 174
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY INADS 152 14 INADS Connection (with Power Fail Transfer) !CAUTION: Chec k loc al reg ulations reg ard ing this c onnec tion method . In this c onfig uration, the INADS line and the emergenc y telep hone extension are bridged together. Fi g u re 4 6 shows the U.S./Atlas p latform. Fi g u re 4 7 shows the European p latform. Figure 46. INADS Connection (US/Atlas Platform)1. PARTNER System...
Page 175
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY INADS 153 14 Figure 47. INADS Connection (European Platform) Standard Reliability nNormal connection : Connec t the INADS tip and ring p ort from the AUX c onnec tor (wire p air 50 and 25) to the tip /ring p air of CO line p ort 1 on the PARTNER system. nUS/Atlas/Spain platform connection : Connec t station 10 to the INADS port. nEuropean platform connection : Brid g e the outsid e p...
Page 176
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY INADS 154 14 High Reliability Be s u re t h a t t h e TN 1 6 4 8 B SYSAM c irc u i t p a c k s a re l o c a t e d in d i ff e re n t D EFI N I TY c ab inets or proc essor c arriers. 1. Bridg e the 2 INADS tip /ring ports. A 258A ad ap ter may b e used . 2. Connect the bridged INADS tip/ring port to a PARTNER station port. INADS Connection (without Power Fail Transfer) !CAUTION:...
Page 177
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY INADS 155 14 Standard Reliability Normal c onnec tion: 1. Connec t a system telep hone to station 10 on the PARTNER system. 2. Connec t a stand ard RJ-11 telephone line c ord from the PARTNER CO line to the CO line p rotec tor. 3. Connec t the INADS tip and ring p ort from the AUX c onnec tor to the tip /ring p air of CO line p ort 1 on the PARTNER via the MDF. See Fig ure 48 . Use wire...
Page 178
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY INADS 156 14 7. Enter 2 to set the station p ort to analog rotary. Enter 1 if an analog DTMF telep hone or PARTNER system telep hone is c onnec ted . 8. Enter # to return to the start of the p rog ramming mode. Set PARTNER CO Line Port (All Platforms) 1. Enter # 2 0 1 . 2. Press 1 for tone or 2 for pulse mode. 3. Enter # to return to the start of the p rog ramming mode. Set...
Page 179
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY INADS 157 14 Installation Test (All Installations) These tests c onfirm that the hard ware and ad ministration are c orrec t. 1. Plac e an outg oing c all from the INADS p ort. Chec k for normal talk p ath. 2. Plac e an inc oming c all to the INADS p ort. Chec k for normal talk p ath. 3. Plac e an outg oing d ata from the INADS p ort to verify c onnec tion. A failure in the link b etween...
Page 180