Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 171

DEFINITY INADS 
149  
14
DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
14
DEFINITY INADS
The DEFINITY ECS Initialization and  Administration System (INADS) p rovid es 
analog  loop bac k c onnec tions and  PARTNERĀ® c onnec tions for remote alarming 
and  maintenanc e when d irec t c onnec tion to the p ub lic  network is not p ossib le.
NOTE:
These instruc tions are for DEFINITY ECS Release 7r or later systems using  
the TN1648/B system ac c...

Page 172

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DEFINITY INADS 
150  
14
Figure 45. Analog Loopback Connections R8r
Installing INADS Analog Loopback on a High-
Reliability System
Be  su re  t o  p la c e  t h e  TN 1 6 4 8 B  SYSAM  c irc u i t  p a c ks  i n  d iff e re n t  c a b i n e t s  o r 
p roc essor c arriers. Also b e sure to p lac e the analog  line c irc uit p ac ks in the 
same c ab inets or c arriers as the TN1648 c irc uit p ac ks.
1....

Page 173

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DEFINITY INADS 
151  
14
Administering DEFINITY ECS for INADS
NOTE:
Ad d 2 p auses in front of the d ial string  when using  c ut-throug h trunks. 
Pauses are not required if using ARS.
1. Type change system-parameters maintenance
 and press 
En t e r.
2. For hig h reliab ility systems, in the see interchange: 
field, type daily
 
and  p ress 
En t e r. This is d one in c ase 1 of the c onnec tions b...

Page 174

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DEFINITY INADS 
152  
14
INADS Connection (with Power Fail Transfer)
!CAUTION:
Chec k loc al reg ulations reg ard ing  this c onnec tion method .
In this c onfig uration, the INADS line and  the emergenc y telep hone extension are 
bridged together. Fi g u re  4 6
 shows the U.S./Atlas p latform. Fi g u re  4 7 shows the 
European p latform.
Figure 46. INADS Connection (US/Atlas Platform)1. PARTNER System...

Page 175

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DEFINITY INADS 
153  
14
Figure 47. INADS Connection (European Platform)
Standard Reliability 
nNormal connection
: Connec t the INADS tip  and  ring  p ort from the AUX 
c onnec tor (wire p air 50 and  25) to the tip /ring  p air of CO line p ort 1 on the 
PARTNER system. 
nUS/Atlas/Spain platform connection
: Connec t station 10 to the INADS 
port. 
nEuropean platform connection
: Brid g e the outsid e p...

Page 176

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DEFINITY INADS 
154  
14
High Reliability
Be  s u re  t h a t  t h e  TN 1 6 4 8 B  SYSAM  c irc u i t  p a c k s a re  l o c a t e d  in  d i ff e re n t  D EFI N I TY 
c ab inets or proc essor c arriers. 
1. Bridg e the 2 INADS tip /ring  ports. A 258A ad ap ter may b e used . 
2. Connect the bridged INADS tip/ring port to a PARTNER station port.
INADS Connection (without Power Fail Transfer)
!CAUTION:...

Page 177

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DEFINITY INADS 
155  
14
Standard Reliability
Normal c onnec tion:
1. Connec t a system telep hone to station 10 on the PARTNER system.
2. Connec t a stand ard  RJ-11 telephone line c ord  from the PARTNER CO line 
to the CO line p rotec tor.
3. Connec t the INADS tip and  ring p ort from the AUX c onnec tor to the tip /ring  
p air of CO line p ort 1 on the PARTNER via the MDF. See Fig ure 48
. Use 
wire...

Page 178

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DEFINITY INADS 
156  
14
7. Enter 2
 to set the station p ort to analog  rotary. Enter 1
 if an analog  DTMF 
telep hone or PARTNER system telep hone is c onnec ted .
8. Enter #
 to return to the start of the p rog ramming  mode.
Set PARTNER CO Line Port (All Platforms)
1. Enter # 2 0 1
. 
2. Press 1
 for tone or 2
 for pulse mode.
3. Enter #
 to return to the start of the p rog ramming  mode. 
Set...

Page 179

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DEFINITY INADS 
157  
14
Installation Test (All Installations)
These tests c onfirm that the hard ware and  ad ministration are c orrec t.
1. Plac e an outg oing  c all from the INADS p ort. Chec k for normal talk p ath.
2. Plac e an inc oming  c all to the INADS p ort. Chec k for normal talk p ath.
3. Plac e an outg oing  d ata from the INADS p ort to verify c onnec tion.
A failure in the link b etween...

Page 180

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DEFINITY INADS 
158  
14 
Start reading Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual

Related Manuals for Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual

All Lucent Technologies manuals