Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 201

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Multimedia Communications Products: MMCX, MMCH, ESM 
179 Multimedia Call Handling (MMCH) 
18
Connect the Endpoints
Use the following  p roc ed ure and  Fig ure 64 to c onnec t the end p oints:
Figure 64. Typical Multimedia Call Handling Connections
1. Eac h PC MMCH end p oint must c ontain a BRI ad ap ter.
2. Connec t a DCP telep hone to a d ig ital line c irc uit p ac k. The DCP telep hone 
must b e used...

Page 202

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Multimedia Communications Products: MMCX, MMCH, ESM 
180 Multimedia Call Handling (MMCH) 
18
Administer the Endpoints
1. Log  in and  enter add data-next
 < or a valid  extension numb er> .
2. The d ata mod ule form ap p ears. On p ag e 1 of the form, enter the Data 
Extension
: xxxx,
 Type
: 7500
, the Name
: user’s name (suc h as 
ProShare), and  enter y
 in Multimedia?
 field .
3. On p ag e 2 of the...

Page 203

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Multimedia Communications Products: MMCX, MMCH, ESM 
181 Multimedia Call Handling (MMCH) 
18
These end p oints d o not need  any spec ial c onfig uration setting s. The stand ard  
Pic tureTel c onfig uration for a DEFINITY ECS is as follows. 
1. Load  the LiveShare Plus software first.
2. Enter the user name and company name. Use default values for 
sub sequent p rompts.
3. Enter a site name.
4. Selec t...

Page 204

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Multimedia Communications Products: MMCX, MMCH, ESM 
182 Multimedia Call Handling (MMCH) 
18
c onflic t with the interrup t (IRQ) p ort setting . Chec k the Pic tureTel 
c onfig uration to make sure that the IRQ p ort is set to 11. If 
initialization is still a p rob lem, c ontac t a Pic tureTel rep resentative.
2. Open the Pic tureTel ap p lic ation p rog ram.
3. Two wind ows should  ap p ear: one loc al...

Page 205

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Multimedia Communications Products: MMCX, MMCH, ESM 
183 Multimedia Call Handling (MMCH) 
18
ProShare Configuration
The ProShare system must b e set up  so that it d oes not look for a Servic e Profile 
Id entifier (SPID) when c onnec ting  to the DEFINITY ECS. This is imp ortant 
b ec ause you ad minister the ProShare as a sing le 7500 d ata set and  the 
telep hone extension assoc iated  with that d ata...

Page 206

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Multimedia Communications Products: MMCX, MMCH, ESM 
184 Multimedia Call Handling (MMCH) 
18
How to Place a ProShare Video Call
1. Boot the ProShare c omp uter.
2. Open the c amera lens. Be sure the g reen LED is on.
3. Open ProShare Personal Conferencing 
p rog ram group  from the 
Win d o w s
™ Prog ram Manag er sc reen.
4. Double c lic k on the ProShare Conferencing 
ic on.
5. If this is a first time...

Page 207

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Multimedia Communications Products: MMCX, MMCH, ESM 
185 Multimedia Call Handling (MMCH) 
18
Solution
: Und er “ Aliasing ,”  enter the d ata extension numb er. To d o this:
a. Go to the ProShare d irec tory and run the Diag nostic s and Utilities 
program.
b . Double c lic k on the Hardware and ISDN Configuration
 utility.
c. Choose ISDN Line Configuration
.
d. Set Protocol = custom
 and Manufacturer =...

Page 208

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Multimedia Communications Products: MMCX, MMCH, ESM 
186 Multimedia Call Handling (MMCH) 
18
Zydacron Configuration
These end p oints d o not need  any spec ial c onfig uration setting s. The stand ard  
c onfig uration for a DEFINITY ECS is as follows. Use the d oc umentation that 
ac c omp anies the Zyd ac ron eq uip ment for more d etails. 
1. Open Wind ows and  load  the software ap plic ation.
2....

Page 209

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Multimedia Communications Products: MMCX, MMCH, ESM 
187 Multimedia Call Handling (MMCH) 
18
7. Selec t ANSWER on the test end p oint or p ic k up the test telep hone 
hand set.
8. Remote vid eo ap p ears on the loc al sc reen and  a talk p ath is op ened  on 
the head set. For a test telephone, a talk p ath is op ened.
Troubleshooting the Zydacron
Symptom
: After eac h PC reb oot, the first time you b...

Page 210

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Multimedia Communications Products: MMCX, MMCH, ESM 
188 Multimedia Call Handling (MMCH) 
18
Figure 65. Typical Multimedia Call handling ESM Connections
ESM Installation
Use the following  p roc ed ure and  Fig ure 65 to c onnec t to the ESM eq uip ment:
1. Install the TN2207 p rimary rate interfac e (PRI) c irc uit p ac k and  the 
TN787F/G/H/J/K multimed ia interfac e (MMI) c irc uit p ac k in the...