Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 201
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Multimedia Communications Products: MMCX, MMCH, ESM 179 Multimedia Call Handling (MMCH) 18 Connect the Endpoints Use the following p roc ed ure and Fig ure 64 to c onnec t the end p oints: Figure 64. Typical Multimedia Call Handling Connections 1. Eac h PC MMCH end p oint must c ontain a BRI ad ap ter. 2. Connec t a DCP telep hone to a d ig ital line c irc uit p ac k. The DCP telep hone must b e used...
Page 202
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Multimedia Communications Products: MMCX, MMCH, ESM 180 Multimedia Call Handling (MMCH) 18 Administer the Endpoints 1. Log in and enter add data-next < or a valid extension numb er> . 2. The d ata mod ule form ap p ears. On p ag e 1 of the form, enter the Data Extension : xxxx, Type : 7500 , the Name : user’s name (suc h as ProShare), and enter y in Multimedia? field . 3. On p ag e 2 of the...
Page 203
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Multimedia Communications Products: MMCX, MMCH, ESM 181 Multimedia Call Handling (MMCH) 18 These end p oints d o not need any spec ial c onfig uration setting s. The stand ard Pic tureTel c onfig uration for a DEFINITY ECS is as follows. 1. Load the LiveShare Plus software first. 2. Enter the user name and company name. Use default values for sub sequent p rompts. 3. Enter a site name. 4. Selec t...
Page 204
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Multimedia Communications Products: MMCX, MMCH, ESM 182 Multimedia Call Handling (MMCH) 18 c onflic t with the interrup t (IRQ) p ort setting . Chec k the Pic tureTel c onfig uration to make sure that the IRQ p ort is set to 11. If initialization is still a p rob lem, c ontac t a Pic tureTel rep resentative. 2. Open the Pic tureTel ap p lic ation p rog ram. 3. Two wind ows should ap p ear: one loc al...
Page 205
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Multimedia Communications Products: MMCX, MMCH, ESM 183 Multimedia Call Handling (MMCH) 18 ProShare Configuration The ProShare system must b e set up so that it d oes not look for a Servic e Profile Id entifier (SPID) when c onnec ting to the DEFINITY ECS. This is imp ortant b ec ause you ad minister the ProShare as a sing le 7500 d ata set and the telep hone extension assoc iated with that d ata...
Page 206
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Multimedia Communications Products: MMCX, MMCH, ESM 184 Multimedia Call Handling (MMCH) 18 How to Place a ProShare Video Call 1. Boot the ProShare c omp uter. 2. Open the c amera lens. Be sure the g reen LED is on. 3. Open ProShare Personal Conferencing p rog ram group from the Win d o w s ™ Prog ram Manag er sc reen. 4. Double c lic k on the ProShare Conferencing ic on. 5. If this is a first time...
Page 207
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Multimedia Communications Products: MMCX, MMCH, ESM 185 Multimedia Call Handling (MMCH) 18 Solution : Und er “ Aliasing ,” enter the d ata extension numb er. To d o this: a. Go to the ProShare d irec tory and run the Diag nostic s and Utilities program. b . Double c lic k on the Hardware and ISDN Configuration utility. c. Choose ISDN Line Configuration . d. Set Protocol = custom and Manufacturer =...
Page 208
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Multimedia Communications Products: MMCX, MMCH, ESM 186 Multimedia Call Handling (MMCH) 18 Zydacron Configuration These end p oints d o not need any spec ial c onfig uration setting s. The stand ard c onfig uration for a DEFINITY ECS is as follows. Use the d oc umentation that ac c omp anies the Zyd ac ron eq uip ment for more d etails. 1. Open Wind ows and load the software ap plic ation. 2....
Page 209
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Multimedia Communications Products: MMCX, MMCH, ESM 187 Multimedia Call Handling (MMCH) 18 7. Selec t ANSWER on the test end p oint or p ic k up the test telep hone hand set. 8. Remote vid eo ap p ears on the loc al sc reen and a talk p ath is op ened on the head set. For a test telephone, a talk p ath is op ened. Troubleshooting the Zydacron Symptom : After eac h PC reb oot, the first time you b...
Page 210
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Multimedia Communications Products: MMCX, MMCH, ESM 188 Multimedia Call Handling (MMCH) 18 Figure 65. Typical Multimedia Call handling ESM Connections ESM Installation Use the following p roc ed ure and Fig ure 65 to c onnec t to the ESM eq uip ment: 1. Install the TN2207 p rimary rate interfac e (PRI) c irc uit p ac k and the TN787F/G/H/J/K multimed ia interfac e (MMI) c irc uit p ac k in the...