Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual

Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual

Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 61

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Data Modules and Asynchronous Data Units 
39 Connect Data Modules 
4
Setting interface options on 7400A DCE
1. To ac c ess the menus, p ress the NEXT/NO
 b utton.  
2. When the SET OPTIONS?
 p romp t ap p ears on the LCD. Press the NEXT/
NO
 b utton. 
3. The VIEW OPTIONS?
 prompt appears. Press the NEXT/NO
 b utton. 
You will return to the op tions menus in a minute. But first you must selec t a 
c ommand...

Page 62

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Data Modules and Asynchronous Data Units 
40 Connect Data Modules 
4
5. For each prompt, if you want to select the interface, press the ENTER/YES
 
b utton or, if you want a d ifferent interfac e, p ress the NEXT/NO
 b utton.  
a. Enab le the answer-only interfac e if the d ata mod ule must op erate 
without any kind  of external c ontrol:   
b . Enab le the AT-c ommand  interfac e if users need  to c...

Page 63

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Data Modules and Asynchronous Data Units 
41 Connect Data Modules 
4
Setting speed options on 7400A DCE
1. Press the NEXT/NO
 b utton to c ontinue with the setup  p roc ed ure.  
2. The SET OPTIONS?
 p rompt ap p ears on the LCD. Press the ENTER/YES
 
b utton. 
A series of SET 
number SPEED?
 prompts appears.  
3. Press the NEXT/NO
 b utton until you see the SET 9600 SPEED?
 p romp t. 
Then press the...

Page 64

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Data Modules and Asynchronous Data Units 
42 Connect Data Modules 
4
6. The SET 19200 SPEED?
 p romp t ap p ears. Press the NEXT/NO
 b utton. 
7. If you selec ted  the AT-c ommand  interfac e in the sec tion ‘‘Setting  interfac e 
op tions on 7400A DCE’’ (ab ove), you are finished  c onfiguring  the 7400A 
data module.  
Setting the automatic-answer feature on 7400A DCE 
You c an set up  the 7400A d ata...

Page 65

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Data Modules and Asynchronous Data Units 
43 Connect Data Modules 
4
4. The CONTINUE?
 prompt appears. Press the ENTER/YES
 b utton.  
Setting the break-disconnect option on 7400A DCE 
This setting  sp ec ifies the leng th of the BREAK sig nal, a string  of 10 or more 
sp ac es that tells the host that the user need s to interrup t op erations. There are 
three options: TRIPLE, LONG (the d efault), and...

Page 66

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Data Modules and Asynchronous Data Units 
44 Connect Data Modules 
4
2. If you pressed the ENTER/YES
 b utton at the SET LeadName LEAD?
 
prompt, 
the 
LeadName -> ON?
 p rompt ap p ears.  Press the ENTER/YES
 
b utton. 
3. Rep eat until all lead s have b een set. 
Setting parity on 7400A DCE
Next you need to id entify the type of p arity c od ing  that the d ata mod ule should  
exp ec t. Parity is an...

Page 67

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Data Modules and Asynchronous Data Units 
45 Connect Data Modules 
4
Configuring the ring indicator on 7400A DCE
The ring -ind ic ator (p in 22) setting  c an have either of two values: CYCLE
 or ON
 
(the d efault). 
1. Ac c ep t the d efault values, unless otherwise instruc ted . When the SET RI 
LEAD?
 promp t ap p ears, p ress the NEXT/NO b utton to keep  the d efault, 
ON. 
Enabling remote loopback on...

Page 68

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Data Modules and Asynchronous Data Units 
46 Connect Data Modules 
4
Enabling test mode on 7400A DCE
The test-mode (p in 25) setting  c an have either of two values: ON
 or OFF
 (the 
d efault).
1. Ac c ep t the d efault values, unless otherwise instruc ted . When the SET TM 
LEAD?
 promp t ap p ears, p ress the NEXT/NO
 b utton to keep  the d efault, 
ON
. 
Exiting menus and saving changes on 7400A DCE
1....

Page 69

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Data Modules and Asynchronous Data Units 
47 Connect Data Modules 
4
You return HOME. 
Checking DEFINITY administration  on 7400A DCE
Chec k that the DEFINITY is ad ministered to sup p ort the 7400A d ata mod ule in 
the DCE ap p lic ation as follows:
1. If nec essary, return to the HOME d isp lay on the 7400A b y p ressing  the 
NEXT/NO
 and  BACK buttons at the same time.
2. From the HOME d isp lay, p...

Page 70

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
Data Modules and Asynchronous Data Units 
48 Connect Data Modules 
4
2. When the SET OPTIONS?
 p romp t ap p ears on the LCD, p ress the ENTER/
YES
 button.    
A series of SET 
number SPEED?
 prompts appears.  
3. Press the NEXT/NO
 b utton until you see the SET 9600 SPEED?
 p romp t. 
Then press the ENTER/YES
 b utton.  
Most DEFINITY c onnec tions op erate at the 9600 sp eed .
4. The 9600 = OFF?
 prompt...