Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 21
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Federal Communications Commission Statement xxi Means of connection Connec tion of this equip ment to the telep hone network is shown in the following tab le. If the terminal eq uip ment (DEFINITY ® System) c auses harm to the telep hone network, the telep hone c omp any will notify you in ad vanc e that temp orary d isc ontinuanc e of servic e may b e req uired . But if ad vanc e notic e is not...
Page 22
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Federal Communications Commission Statement xxii
Page 23
909A/B Universal Coupler 1 1 DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 1 909A/B Universal Coupler The 909A/B Universal Coup ler is used with pag ing and music -on-hold eq uip ment that is not ap p roved for use with the p ub lic network. NOTE: If the music sourc e is reg istered b y the FCC (in the USA) or an eq uivalent b od y, the 909A/B is not required . Fi g u re 1 shows a typ ic al 909A/B universal c oup ler. For ad d itional...
Page 24
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 909A/B Universal Coupler 2 1 Figure 1. Typical 909A/B Universal Coupler The 909A is the DC version of the c oup ler, and c ab inet power sup p lies -48 VDC p ower. The 909B is the AC-p owered version and p ower is sup p lied from a sep arate power sup p ly (suc h as the KS-22911L2). The DIP switches on the unit set: n Protec tion/Pag ing selec tion — For AUX trunk p ag ing and malic ious c all...
Page 25
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 909A/B Universal Coupler 3 1 Table 1. J1 Pin Assignments (System Connections) Pin Color Designation Description 1 White-Orang e — Not Used 2 Orang e PG2/BZ2 Seizure c ontrol lead , c onnec ted to -48 VDC from the system or from the 909A/B when the p rotec tion p ag ing switc h is set to C2, or to -48 VDC on the 909A/B when p rotec tion/p ag ing switc h is set to C1 3 White-Green PG1/BZ1 Seizure...
Page 26
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 909A/B Universal Coupler 4 1 !CAUTION: Damag e to the 909A/B may oc c ur if the c ab le is p lug g ed into J3 before all c ross-c onnec ts are c omp leted . Fi g u re 2 shows the p hysic al loc ations of the p ins for J1, J2, and J3. Figure 2. Typical Modular Jack Pinout Table 3. J3 Pin Assignments (Power Connections) Pin Color Designation Description 1, 3, 4, & 7— — Not used 2 Blac k GRD -48 RET or...
Page 27
Auxiliary Power Supplies 5 Local, auxiliary power supply 2 DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 2 Auxiliary Power Supplies Nonessential features of the attend ant c onsole, suc h as the op tional 27B1 selec tor c onsole, and DCP terminals d erive their p ower from an auxiliary p ower sourc e. One c onsole c an c onnec t to R8c si, and 3 c onsoles c an c onnec t to eac h c ab inet stac k or R8r. Eac h c ab inet c an d erive auxiliary p...
Page 28
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Auxiliary Power Supplies 6 Applications that require auxiliary power 2 Applications that require auxiliary power Auxiliary power (local or bulk) is always required for the following: n Any 8520 terminal n Attend ant c onsole 302C1 n PassageWay ad ap ter interfac e n Any 7500-series terminal whether in passive b us, or p oint to point (one p er BRI p ort) n Any 7500- or 8500-series terminal with an...
Page 29
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Auxiliary Power Supplies 7 Sources of auxiliary, local power 2 Sources of auxiliary, local power An attendant console can derive auxiliary power from: n A bulk power supply, such as the 1145B A c onsole’s maximum distanc e from its 1145B auxiliary p ower sourc e is 800 ft (244 m) for a 302A1 or 350 ft (107 m) for a 301B1 and 302C1. n 1151A1 or 1151A2 p ower sup p ly Required Safety Precautions...
Page 30
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Auxiliary Power Supplies 8 1145B Power Supply 2 !DANGER: Never let the op erating temp erature of the unit exc eed the rec ommend ed maximum. Do not b loc k or c over the ventilation op ening s in the c ase. Do not let anything rest on the unit. !DANGER: Do not attempt to rec harg e b atteries. The p ower unit rec harges the b atteries itself. Any other rec harg ing method may c ause leaks of c...