Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 41
Voice and Data Terminals and Extenders 19 2-Wire DCP Endpoint 3 DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 3 Voice and Data Terminals and Extenders This c hapter p rovid es information on 2-wire voic e and d ata terminals and DEFINITY d ig ital c ommunic ation p rotoc ol (DCP) extend ers. 2-Wire DCP Endpoint Wire the tip and ring c onnec tions of 2-wire DCP end p oints to a TN2224B d ig ital line 2-wire c irc uit pac k (or eq uivalent)...
Page 42
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Voice and Data Terminals and Extenders 20 2-Wire DCP Endpoint 3 2-Wire Voice and Data Terminals Tab le 10 p rovid es the p in-out c onfig uration for 2-wire voic e and d ata terminals. Fi g u re 7 shows a workstation c onnec ting to a d ata ad ap ter. The line sid e of the ad ap ter c onnec ts to the TN2181 d ig ital line 2-wire c irc uit p ac k via the main d istrib ution frame (MDF) (to the system...
Page 43
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Voice and Data Terminals and Extenders 21 2-Wire DCP Endpoint 3 Figure 7. Typical Connections to a 2-Wire DCP Workstation Wire the c irc uit p ac k to the MDF with a 25-p air c able: 1. Wire to the data ad ap ter p er loc al stand ard s. 2. Wire the d ata terminal and telephone as instruc ted in the d oc ument ac c omp anying the d ata ad ap ter. 1. 103A or mod ular wall jac k 2. 2-wire endpoint 3....
Page 44
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Voice and Data Terminals and Extenders 22 DEFINITY DCP Extender, Stand Alone 3 DEFINITY DCP Extender, Stand Alone The fig ure b elow shows a typ ic al c onnec tion from a d ig ital line 2-wire DCP c irc uit p ac k throug h two DCP extender d evic es. See Ap p end ix A, ‘‘Connec tor and Cab le Pinout Charts’’ for c ab ling information and pin assignments. Figure 8. Typical DEFINITY DCP Extender...
Page 45
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Voice and Data Terminals and Extenders 23 DEFINITY DCP Extender, Rack Mount 3 DEFINITY DCP Extender, Rack Mount Fi g u re 9 shows a typ ic al rac k mount (multi-mount) DCP extender. Connec tions from either a d ig ital line 17-p ort 2-wire DCP c irc uit p ac k or a d ig ital line 24-p ort 2- wire DCP c irc uit p ac k, are mad e throug h two DCP extend er d evic es. The stand alone extend er installs...
Page 46
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Voice and Data Terminals and Extenders 24 DEFINITY DCP Extender, Rack Mount 3
Page 47
Data Modules and Asynchronous Data Units 25 Understanding RS-232 communications 4 DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 4 Data Modules and Asynchronous Data Units Data modules c onnec t p erip heral eq uip ment to the DEFINITY ECS or DEFINITY ONE and c onvert b etween the RS-232 c ommunic ations p rotoc ol used b y p erip herals and the DEFINITY Dig ital Communic ations Protoc ol (DCP). Possib le peripherals include AUDIX adjunct...
Page 48
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 26 Understanding RS-232 communications 4 The RS-232 c ommunic ations p rotoc ol d efines a c ommunic ations link as a Data Communic ations Eq uipment (DCE) d evic e and a Data Terminal Eq uip ment (DTE) d evic e c onnec ted b y an RS-232 c able. The send and rec eive p ins on DCE eq uip ment (p ins 2 and 3) are reversed on DTE eq uip ment, so that the DCE...
Page 49
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 27 Installation Procedure 4 Installation Procedure To install a typic al d ata mod ule, you p erform the following tasks: 1.Obtain Req uired Eq uip ment 2.Sett Hard ware Op tions (must b e c omp leted b efore you ad minister or p hysic ally c onnec t the d ata mod ule) 3.Connec t Data Modules 4.Ad minister the DEFINITY ECS for Data Mod ules (c an b e c omp...
Page 50
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 28 Sett Hardware Options 4 Setting 7400A Data-Module Hardware Options Most c onfig uration op tions are c ontrolled b y c ommands entered on the front p anel of the 7400A. But you have to make hard ware c hang es when you want to set up the 7400A d ata-mod ule for use in a mod em p ool or as a p iec e of d ata c ommunic ations eq uip ment. In a mod em-p ool,...