    							Cleaning the Printer 7-6
    Note
    Do not touch the PC drum and the transfer belt on the imaging 
    cartridge. 
    Position the removed imaging 
    cartridge horizontally as shown in 
    the illustration at the right.
    Be sure to keep the imaging 
    cartridge horizontal and place it 
    where it will not become dirty.
    Do not leave the imaging 
    cartridge removed for more than 
    15 minutes, and do not place the 
    removed imaging cartridge in a 
    location where it would be 
    exposed to direct light (such as 
    sunlight).
    3Clean the media feed rollers by 
    wiping them with a soft, dry 
    cloth.
    BOTTOM
    VIEW
    Downloaded From ManualsPrinter.com Manuals 
    						
    							Cleaning the Printer7-7
    CAUTION
    The area around the fuser unit is 
    extremely hot.
    Touching anything other than the 
    indicated levers may result in 
    burns. If you get burned, 
    immediately cool the skin under 
    cold water, and then seek 
    professional medical attention.
    Note
    Decreased print quality may 
    result if the surface of the 
    transfer roller is touched.
    Be careful not to touch the 
    surface of the transfer roller.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							Cleaning the Printer 7-8
    4Slowly insert the imaging car-
    tridge vertically, and then push it 
    slightly down toward you to fin-
    ish reinstalling the imaging car-
    tridge.
    5Carefully close the top cover.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							Cleaning the Printer7-9
    Cleaning the Print Head Window
    1Perform the operation described below to switch the printer to the P/H 
    CLEAN UP mode.
    Press Key Until Display Reads
    IDLE
    MENU
    MAIN MANU
    MAIN MENU 
    PRINT MENU
     × 2MAIN MENU 
    QUALITY MENU
    QUALITY MENU
    REPLACE TONER
     × 3QUALITY MENU
    P/H CLEAN UP
    P/H CLEAN UP
    *YES
    *YES
    IS SELECTED
    Then, it displays 
    OPEN DOOR
    REMOVE TONER
    Downloaded From ManualsPrinter.com Manuals 
    						
    							Cleaning the Printer 7-10
    To exit P/H CLEAN UP mode, press the Cancel key.
    2Open the front cover.
    Before opening the front 
    cover, open Tray 1 if it is 
    not already open.
    3The magenta toner cartridge has 
    been moved to the position from 
    where it can be replaced.
    Pull down the handle on the 
    toner cartridge until the toner 
    cartridge is unlocked and moves 
    out slightly toward you.
    Remove the toner cartridge.
    When the magenta toner 
    cartridge is removed, a 
    gap is created within the 
    printer so that the print 
    head window can easily 
    be cleaned.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							Cleaning the Printer7-11
    Note
    Do not touch the contact 
    indicated in the illustration.
    4Close the front cover.
    The toner cartridge rotate 
    within the printer.
    5After the toner cartridges have 
    finished rotating, open the top 
    cover.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							Cleaning the Printer 7-12
    6Grab the handle and lift it up 
    slightly to the back, and then 
    slowly pull the imaging cartridge 
    out vertically.
    Note
    Do not touch the PC drum and the transfer belt on the imaging 
    cartridge. 
    Position the removed imaging 
    cartridge horizontally as shown in 
    the illustration at the right.
    Be sure to keep the imaging 
    cartridge horizontal and place it 
    where it will not become dirty.
    Do not leave the imaging 
    cartridge removed for more than 
    15 minutes, and do not place the 
    removed imaging cartridge in a 
    location where it would be 
    exposed to direct light (such as 
    sunlight).
    Downloaded From ManualsPrinter.com Manuals 
    						
    							Cleaning the Printer7-13
    7Clean the print head window by 
    wiping it with a soft, dry cloth.
    CAUTION
    The area around the fuser unit is 
    extremely hot.
    Touching anything other than the 
    indicated levers may result in 
    burns. If you get burned, 
    immediately cool the skin under 
    cold water, and then seek 
    professional medical attention.
    BOTTOM
    VIEW
    Downloaded From ManualsPrinter.com Manuals 
    						
    							Cleaning the Printer 7-14
    Note
    Decreased print quality may 
    result if the surface of the 
    transfer roller is touched.
    Be careful not to touch the 
    surface of the transfer roller.
    8Slowly insert the imaging car-
    tridge vertically, and then push it 
    slightly down toward you to fin-
    ish reinstalling the imaging car-
    tridge.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							Cleaning the Printer7-15
    9Close the top cover.
    10After the toner cartridges have 
    finished rotating, open the front 
    cover.
    Downloaded From ManualsPrinter.com Manuals 
    						
    All Konica manuals Comments (0)

    Related Manuals for Konica Minolta magicolor 1650EN User Manual