Replacing Consumables 6-10 Note Do not touch the contact indicated in the illustration. 9Press in the toner cartridge until it locks into place. 10Close the front cover. Downloaded From ManualsPrinter.com Manuals
Replacing Consumables6-11 The printer must complete a calibration cycle after the toner car- tridge has been replaced. If you open the top or front cover before the message IDLE appears, the printer stops and repeats the cal- ibration cycle. Downloaded From ManualsPrinter.com Manuals
Replacing Consumables 6-12 Removing All Toner Cartridges Note Be careful not to spill toner while removing a toner cartridge. If toner spills, immediately wipe it off with a soft, dry cloth. By using the REMOVE ALL mode, all toner cartridges can be removed. Follow the procedure described below to use the REMOVE ALL mode. 1Perform the operation described below to switch the printer to the REMOVE ALL mode. Press Key Until Display Reads IDLE MANU MAIN MANU MAIN MENU PRINT MENU × 2MAIN MENU QUALITY MENU QUALITY MENU REPLACE TONER REPLACE TONER BLACK REPLACE TONER REMOVE ALL Downloaded From ManualsPrinter.com Manuals
Replacing Consumables6-13 It is not possible to exit REMOVE ALL mode before the operation is finished (even if the Cancel key is pressed). If the printer has incorrectly been switched to REMOVE ALL mode, open, then close the front cover four times to exit REMOVE ALL mode. 2Open the front cover. Before opening the front cover, open Tray 1 if it is not already open. REMOVE ALL *NO REMOVE ALL YES *YES IS SELECTED Then, it displays OPEN DOOR AND REMOVE M TONER Press Key Until Display Reads Downloaded From ManualsPrinter.com Manuals
Replacing Consumables 6-14 3Pull down the handle on the toner cartridge until the toner cartridge is unlocked and moves out slightly toward you. Remove the toner cartridge. Do not manually rotate the toner cartridge carou- sel. In addition, do not rotate the carousel with force, otherwise it may be damaged. Note Do not touch the contact indicated in the illustration. Downloaded From ManualsPrinter.com Manuals
Replacing Consumables6-15 4Close the front cover. 5Follow the same procedure to remove the cartridges for the cyan, black, then yellow toners. Downloaded From ManualsPrinter.com Manuals
Replacing Consumables 6-16 Replacing the Imaging Cartridge When replacing an imaging cartridge, refer to the following table. For opti- mum print quality and performance, use only approved KONICA MINOLTA imaging cartridge for your specific printer type, as listed in the table below. You can find your machine type and the imaging cartridge part numbers on the consumables reorder label inside the top cover your machine. For optimum print quality and performance, use only the corre- sponded TYPE genuine KONICA MINOLTA imaging cartridge. 1Open the top cover. If there is paper in the output tray, remove it, and then fold up the out- put tray before opening the top cover. 2Grab the handle and lift it up slightly to the back, and then slowly pull the imaging cartridge out vertically. Printer Ty p ePrinter Part NumberPart Name Imaging Cartridge Part Number AM A034 012 Imaging Cartridge A0VU 011 EU A034 022 A0VU 0Y1 AP A034 042 A0VU 0Y1 GC A034 082 A0VU 0Y1 Downloaded From ManualsPrinter.com Manuals
Replacing Consumables6-17 Note Dispose of the used imaging cartridge according to your local regulations. Do not burn the imaging cartridge. 3Prepare the new imaging cartridge. Note Do not touch the PC drum and the transfer belt on the imaging cartridge. 4Slowly insert the new imaging cartridge vertically, and then push it slightly down toward you to finish installing the imaging cartridge. Downloaded From ManualsPrinter.com Manuals
Replacing Consumables 6-18 5Carefully close the top cover. The printer must complete a calibration cycle after the imaging car- tridge has been replaced. If you open the top cover before the message IDLE appears, the printer stops and repeats the calibra- tion cycle. Downloaded From ManualsPrinter.com Manuals
Replacing Consumables6-19 Replacing the Fuser Unit For optimum print quality and performance, use only approved KONICA MINOLTA fuser unit for your specific printer type. 1Turn off the printer and discon- nect the power cord. Note There are extremely hot parts within the printer. Before replacing the fuser unit, wait about 20 minutes after turning off the printer, and then check that the fusing section has reached room temperature, otherwise, you may get burnt. 2Open the top cover. If there is paper in the output tray, remove it, and then fold up the out- put tray before opening the top cover. Downloaded From ManualsPrinter.com Manuals