Home
>
Key Voice
>
Communications System
>
Key Voice Voice Processing System Installation And Maintenance Manual
Key Voice Voice Processing System Installation And Maintenance Manual
Here you can view all the pages of manual Key Voice Voice Processing System Installation And Maintenance Manual. The Key Voice manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 502
INSTALLATION AND MAINTENANCE MANUAL 4/0020-120. Installing Voice Boards 20.1 Using Dialogic Voice Boards The following Dialogic boards are described in this section: · DIALOG/4 · ProLine/2V · D/41D · D/41E · D/41H · D160SC-LS Dialogic boards are packed in static-proof bags. Make sure you are grounded when you remove the boards from the bags. You can ground yourself by touching the frame of the computer. All Dialogic boards must be configured via hardware and software. You configure the hardware by...
Page 503
INSTALLATION AND MAINTENANCE MANUAL 4/0020-2SW1JP1JP6JP7JP5IRQ 4IRQ 3IRQ 2IRQ 5IRQ 6IRQ 7Figure 20-1 DIALOG/4 Board Setting the DIALOG/4 Hardware Interrupt The VP system uses hardware interrupt IRQ5 by default. This requires that a shorting jumper be placed in position 4 of JP1. Note:If the system has more that one Dialogic board, all boards must have JP1 set to the samehardware interrupt setting.If you need to use a different hardware interrupt, follow these steps: 1. Make sure the new interrupt chosen...
Page 504
INSTALLATION AND MAINTENANCE MANUAL 4/0020-3· Find the line beginning with the word TONEDNLD, and change the ‘-h5’ to the new interrupt (for example, ‘-h4’ for IRQ 4). · Find the line beginning D40DRV –I62 –Y –E, and change the number after the letter ‘E’ so it reflects the number of ports in the system multiplied by 16. If the system is an 8 port system, for example, the line should read D40DRV –I62 –Y –E128. Setting the DIALOG/4 Memory Address The VP system uses memory addresses D0000, D2000, D4000…...
Page 505
INSTALLATION AND MAINTENANCE MANUAL 4/0020-4[Genload - All Boards] BusType =None D41DInterrupt=5 D41DAddress=D0000 D41DAddress=D2000 To add a board to an existing system, just add one line containing its address. The entry for each board should match the address for that board as shown in Table 20-1. 20.1.3 Installing a ProLine/2V Board (DOS-based VP Systems) Configuring the ProLine/2V Jumper and Switch Settings The positions of the jumpers and switches on the ProLine/2V board are shown in Figure...
Page 506
INSTALLATION AND MAINTENANCE MANUAL 4/0020-53. Edit the configuration file DIALOGIC.CFG to change the statement D41DINTERRUPT = 5 to the new IRQ value. To use a DOS editor to make changes to the file, type EDIT DIALOGIC.CFG then press from the \VM prompt. 4. Edit the GOVM.BAT file. To use a DOS editor to make changes to the file, type EDIT GO.BAT then press from the \VM prompt. · Find the line beginning with the word TONEDNLD, and change the ‘-h5’ to the new interrupt (for example, ‘-h4’ for IRQ 4)....
Page 507
INSTALLATION AND MAINTENANCE MANUAL 4/0020-620.1.4 Installing a D/41D Board (DOS-based VP Systems) Configuring the D/41D Jumper and Switch Settings The positions of the jumpers and switches on the D/41D board are shown in Figure 20-3.SW1 JP1JP6JP7JP5IRQ 4IRQ 3IRQ 2IRQ 5IRQ 6IRQ 7Figure 20-3 D/4xD Board Setting the D/41D Hardware Interrupt The VP system uses hardware interrupt IRQ5 by default. This requires that a shorting jumper be placed in position 4 of JP1. Note:If the system has more that one...
Page 508
INSTALLATION AND MAINTENANCE MANUAL 4/0020-73. Edit the configuration file DIALOGIC.CFG to change the statement D41DINTERRUPT = 5 to the new IRQ value. To use a DOS editor to make changes to the file, type EDIT DIALOGIC.CFG then press from the \VM prompt. 4. Edit the GOVM.BAT file. To use a DOS editor to make changes to the file, type EDIT GO.BAT then press from the \VM prompt. · Find the line beginning with the word TONEDNLD, and change the ‘-h5’ to the new interrupt (for example, ‘-h4’ for IRQ...
Page 509
INSTALLATION AND MAINTENANCE MANUAL 4/0020-820.1.5 Installing a D/41E Board (DOS-based VP Systems) Configuring the D/41E Jumper and Switch Settings The positions of the jumpers and switches on the D/41E board are shown in Figure 20-4.SW1SW2Figure 20-4 D/4xE Board Setting the D/41E Hardware Interrupt Modify the DIALOGIC.CFG file, as described below. Setting the D/41E Memory Address The VP system uses memory addresses D0000, D2000, D4000… by default. To configure these addresses, modify the DIALOGIC.CFG...
Page 510
INSTALLATION AND MAINTENANCE MANUAL 4/0020-920.1.6 Special Connection Notes For Two-Port Boards (DOS-based VP Systems) The Dialogic D/21D and Proine/2V two-port boards differ from most other voice processing boards used with the VP system in that the telephone line jacks are type RJ-11 rather than type RJ-14. Figure 20-5 shows a comparison of the two boards.4-port board withRJ-14 jacksLines 1 & 2Lines 3 & 4Line 1Line 22-port board withRJ-11 jacksFigure 20-5 Line Connections of 4-port & 2-port Dialogic...