GE Security g 
LOCATION 106 - PARTITION 7 ENTRY EXIT TIMERS (6 segments, numerical data) 
Location 106 is used to enter the entry and exit times in seconds. There are 2 separate 
entry and exit times. Valid entries are 10-255 seconds. If all the segments are “0”, the 
entry and exit times for partition 1 will be used. 
Segment 1 Entry time 1 Entry time that will be used when a delay 1 zone 
type initiates an entry delay 
Segment 2  Entry time 2 Exit time that will be used for all zones...

Page 72

         
 
GE Security g 
Programming zone configuration groups 
LOCATIONS 110-169 ARE USED TO CHANGE THE ZONE CONFIGURATIONS AS 
LISTED IN THE TABLE ON PAGES 44-46. THESE LOCATIONS ARE CONSIDERED 
AS ADVANCED PROGRAMMING, AND THEY SHOULD ONLY BE CHANGED IF YOU 
HAVE A THOROUGH UNDERSTANDING OF THE OPERATION OF EACH BIT. 
 
LOCATION 110 - CONFIGURATION GROUP 1 ALARM EVENT CODE (1 segment, numerical data) 
Location 110 contains the event code that is sent for a Contact ID or SIA report. The 
desired...

Page 73

         
 
GE Security g 
Segment 4 1 = On: enables zone activity monitor 
 2 = On: enables end of line resistor defeat on non-fire/non-keyswitch 
zones 
 3 = On : enables zone to act as request to exit input / diables for 
alarm activation 
 4 = On : enables zone to act as access control zone (Door Shunt) 
 5 = Reserved 
 6 = Reserved 
 7 = Reserved 
 8 = Reserved 
 
Segment 5 1-8 Reserved 
 
 
LOCATION 112 - CONFIGURATION GROUP 2 ALARM EVENT CODE (1 segment, numerical data) 
Location 112 contains the...

Page 74

         
 
GE Security g 
LOCATION 117 - CONFIGURATION GROUP 4 CHARACTERISTIC SELECT (5 segments, feature     
selection data) 
Use the “Configuration Group Characteristic Selections” described in Location 111. 
 
LOCATION 118 - CONFIGURATION GROUP 5 ALARM EVENT CODE (1 segment, numerical data) 
Location 118 contains the event code that is sent for a Contact ID or SIA report. The 
desired event code should be chosen from the list on pages 121-122. The zone ID will be 
the zone that is in alarm. 
This...

Page 75

         
 
GE Security g 
LOCATION 124 - CONFIGURATION GROUP 8 ALARM EVENT CODE (1 segment, numerical data) 
Location 124 contains the event code that is sent for a Contact ID or SIA report. The 
desired event code should be chosen from the list on pages 121-122. The zone ID will be 
the zone that is in alarm. 
This location is not used for slow speed formats (like 4+2 and 3+1). This location may 
also contain the alarm report code for the Robofon format (value 00-99). 
 
LOCATION 125 - CONFIGURATION...

Page 76

         
 
GE Security g 
LOCATION 131 - CONFIGURATION GROUP 11 CHARACTERISTIC SELECT (5 segments, feature    
selection data) 
Use the “Configuration Group Characteristic Selections” described in Location 111. 
 
LOCATION 132 - CONFIGURATION GROUP 12 ALARM EVENT CODE (1 segment, numerical data) 
Location 132 contains the event code that is sent for a Contact ID or SIA report. The 
desired event code should be chosen from the list on pages 121-122. The zone ID will be 
the zone that is in alarm. 
This...

Page 77

         
 
GE Security g 
LOCATION 138 - CONFIGURATION GROUP 15 ALARM EVENT CODE (1 segment, numerical data) 
Location 138 contains the event code that is sent for a Contact ID or SIA report. The 
desired event code should be chosen from the list on pages 121-122. The zone ID will be 
the zone that is in alarm. 
This location is not used for slow speed formats (like 4+2 and 3+1). This location may 
also contain the alarm report code for the Robofon format (value 00-99). 
 
LOCATION 139 - CONFIGURATION...

Page 78

         
 
GE Security g 
LOCATION 145 - CONFIGURATION GROUP 18 CHARACTERISTIC SELECT (5 segments, feature     
selection data) 
Use the “Configuration Group Characteristic Selections” described in Location 111. 
 
LOCATION 146 - CONFIGURATION GROUP 19 ALARM EVENT CODE (1 segment, numerical data) 
Location 146 contains the event code that is sent for a Contact ID or SIA report. The 
desired event code should be chosen from the list on pages 121-122. The zone ID will be 
the zone that is in alarm. 
This...

Page 79

         
 
GE Security g 
LOCATION 152 - CONFIGURATION GROUP 22 ALARM EVENT CODE (1 segment, numerical data) 
Location 152 contains the event code that is sent for a Contact ID or SIA report. The 
desired event code should be chosen from the list on pages 121-122. The zone ID will be 
the zone that is in alarm. 
This location is not used for slow speed formats (like 4+2 and 3+1). This location may 
also contain the alarm report code for the Robofon format (value 00-99). 
 
LOCATION 153 - CONFIGURATION...

Page 80

         
 
GE Security g 
LOCATION 159 - CONFIGURATION GROUP 25 CHARACTERISTIC SELECT (5 segments, feature     
selection data) 
Use the “Configuration Group Characteristic Selections” described in Location 111. 
 
LOCATION 160 - CONFIGURATION GROUP 26 ALARM EVENT CODE (1 segment, numerical data) 
Location 160 contains the event code that is sent for a Contact ID or SIA report. The 
desired event code should be chosen from the list on pages 121-122. The zone ID will be 
the zone that is in alarm. 
This...