Home > GE > Control panel > GE Nx 8 Manual

GE Nx 8 Manual

Here you can view all the pages of manual GE Nx 8 Manual. The GE manuals for Control panel are available online for free. You can easily download all the documents as PDF.

Page 61

         
 
GE Security g 
 
Segment 1 Partition 1 “Sensor Low battery Code” 
Segment 2 Partition 2 “Sensor Low battery Code” 
Segment 3 Partition 3 “Sensor Low battery Code” 
Segment 4 Partition 4 “Sensor Low battery Code” 
Segment 5 Partition 5 “Sensor Low battery Code” 
Segment 6 Partition 6 “Sensor Low battery Code” 
Segment 7 Partition 7 “Sensor Low battery Code” 
Segment 8 Partition 8 “Sensor Low battery Code” 
 
LOCATION 61 - SENSOR MISSING COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 
segments,...

Page 62

         
 
GE Security g 
LOCATION 64 - KEYPAD AUXILIARY 2 COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 
segments, numerical data) 
Location 64 contains the tens and ones digits that will be sent for a 4+2 and 3+1 format if 
the keypad “Auxiliary 2” (MEDICAL) is enabled in the partition feature selection. Segment 
1 contains the tens digit; segment 2 contains the ones digit.  
For a 3+1 format, only the segment 1 digit (tens) will be sent. 
 
LOCATION 65 - KEYPAD PANIC COMMUNICATOR CODE, SLOW SPEED...

Page 63

         
 
GE Security g 
LOCATION 69 - LOW BATTERY / LOW BATTERY RESTORE COMMUNICATOR CODES, SLOW SPEED 
FORMATS ONLY (4 segments, numerical data) 
Location 69 contains the tens and ones digits for a 4+2 and 3+1 format that will be sent if 
“Low Battery Reporting” is enabled. Segment 1 contains the tens digit of the “Low Battery 
Reporting”. Segment 2 contains the ones digit of the “Low Battery Reporting”. Segment 3 
contains the tens digit of the “Low Battery Restore”. Segment 4 contains the ones...

Page 64

         
 
GE Security g 
LOCATION 74 - EXPANDER TROUBLE AND EXPANDER TROUBLE RESTORE COMMUNICATOR   
CODES, SLOW SPEED FORMATS ONLY (4 segments, numerical data) 
Location 74 contains the tens and ones digits for a 4+2 and 3+1 format that will be sent if 
“Expander Trouble Reporting” is enabled. Segment 1 contains the tens digit of the 
“Expander Trouble Reporting”. Segment 2 contains the ones digit of the “Expander 
Trouble Reporting”. Segment 3 contains the tens digit of the “Expander Trouble...

Page 65

         
 
GE Security g 
LOCATION 78 - CLOSING COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments,  
numerical data)  
Location 78 contains the tens digit for a 4+2 and 3+1 format if “Closing Reporting” is 
enabled. The ones digit is the ones digit of the user number that did the opening. If the 
user is greater than 9, the numbers will begin repeating (e.g. code 6 = 6, code 45 = 5). 
This location contains 8 segments. Any segment left as “0” will follow the segment 1 
selection. 
If you need to...

Page 66

         
 
GE Security g 
LOCATION 82 - END DOWNLOAD COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (4 
segments, numerical data) 
Location 82 contains the tens and ones digits for a 4+2 and 3+1 format that will be sent if 
“End Downloading Reporting” is enabled. Segment 1 and 2 are reserved. Segment 3 
contains the tens digit of the “End Download Reporting”. Segment 4 contains the ones 
digit of the “End Download Reporting”.  
Note: A start download report will be sent to the internal event log. 
For a...

Page 67

         
 
GE Security g 
Programming partition parameters 
LOCATIONS 88-109 ARE FOR PROGRAMMING DIFFERENT ACCOUNT CODES 
AND/OR FEATURES FOR EACH PARTITION. IF A LOCATION IS LEFT 
UNPROGRAMMED, THE FEATURE FOR PARTITION 1 AND THE ACCOUNT CODE 
FOR THE PHONE NUMBER WILL BE USED 
 
LOCATION 88 - ACCOUNT CODE FOR PARTITION 1 (6 segments, numerical data) 
Location 88 contains the account code that is sent when partition 1 is reported. If location 
88 is left unprogrammed (all “10”s), then the account code...

Page 68

         
 
GE Security g 
LOCATION 92 - ACCOUNT CODE FOR PARTITION 3 (6 segments, numerical data) 
The account code that is sent when reporting partition 3 is programmed in location 92. If 
location 92 is left unprogrammed (all “10”), then the account code corresponding to the 
phone number that is dialled will be used. If the account code is less than six digits, 
program a “10” in the segment immediately after the last digit of the account code. If the 
account code is 6 digits long, program all 6...

Page 69

         
 
GE Security g 
LOCATION 97 - PARTITION 4 ENTRY EXIT TIMERS (6 segments, numerical data) 
Location 97 is used to enter the entry and exit times in seconds. There are 2 separate 
entry and exit times. Valid entries are 10-255 seconds. If all the segments are “0”, the 
entry and exit times for partition 1 will be used. 
Segment 1 Entry time 1 Entry time that will be used when a delay 1 zone 
type initiates an entry delay 
Segment 2  Entry time 2 Exit time that will be used for all zones...

Page 70

         
 
GE Security g 
LOCATION 101 - ACCOUNT CODE FOR PARTITION 6 (6 segments, numerical data) 
The account code that is sent when reporting partition 6 is programmed in location 101. If 
location 101 is left unprogrammed (all “10”) then the account code corresponding to the 
phone number that is dialled will be used. If the account code is less than six digits, 
program a “10” in the segment immediately after the last digit of the account code. If the 
account code is 6 digits long, program all 6...
Start reading GE Nx 8 Manual
All GE manuals