Page 21

         
 
GE Security g 
[*]-[s]  VIEW ZONE STATUS 
 
1. Enter [*]-[s] The LCD screen will display the zone status. 
2. Use the ‘up’ and ‘down’ scroll 
keys to browse through the 
descriptions. 
The LCD screen will display the list of ALL zones, 
in sequential order by zone number. 
3. Press [#] to exit this function. 
 
 
[*]-[3]  VIEW ALARM MEMORY 
 
1. Enter [*]-[3] The LCD screen will display the zone description 
for the zones. 
2. Use the ‘up’ and ‘down’ scroll 
keys to browse through the 
alarm...

Page 22

         
 
GE Security g 
[*]-[6]  ASSIGNING AUTHORITY LEVEL 
 
Note: You must be authorized to access the partition that you wish to add to, or remove 
from, another person’s authority. 
1. Enter [*]-[6] The LCD screen will prompt for a code. 
2. Enter [master code] The LCD screen will prompt for a user number. 
3. Enter the 3 digit user number 
(always 3 digits, i.e. “003” for 
user 3) 
The LCD screen will prompt for a new code. The 
LCD will now prompt you for the first in the 
following list of...

Page 23

         
 
GE Security g 
[*]-[CHIME] ACTIVATING WALKTEST 
 
1. Enter  [*]-[CHIME] The LCD screen will prompt you for a “master 
code”. 
2. Enter [mastercode] The LCD screen will display the “walktest mode” 
3. Activate all sensors to test Each activation of a sensor is confirmed with a 
“ding dong” sound. The zone texts of the sensors 
who have reacted, are displayed one by one on the 
screen. 
4. Enter [mastercode] The walktest mode is left. 
 
 
Remark: 1. All activations and restore conditions...

Page 24

         
 
GE Security g 
 
PROGRAMMING THE NX-8E CONTROL PANEL 
Programming the NX-8E control panel via the LED keypad 
ENTERING THE PROGRAM  MODE 
To enter the program mode, press [*]-[8]. When you do this, the five function LED’s (Stay, 
Chime, Exit, Bypass, and Cancel) will begin to flash. Next, enter the “Go To Program 
Code” (FACTORY DEFAULT IS [9]-[7]-[1]-[3]). If the “Go To Program Code” is valid, the 
“Service” LED will flash and the five function LED’s will illuminate steadily. You are now in...

Page 25

         
 
GE Security g 
EXITING THE PROGRAM MODE  
When all the desired changes in programming have been made, it is time to exit the 
program mode. Press the [Exit] key to exit this programming level, and go to the “Select a 
Module To Program” level. If no additional modules are to be programmed, press the 
[Exit] key again to exit the program mode. If there is a module to be programmed, you 
can select it by entering its address, followed by the [#] key (see “Selecting the Module To 
Program”...

Page 26

         
 
GE Security g Security g 
LOADING FACTORY DEFAULTS LOADING FACTORY DEFAULTS 
To load the factory defaults, enter the program mode using the procedure on page 24, 
then type [9]-[1]-[0]-[#]. The keypad will beep 3 times to indicate that loading is in 
progress. The loading takes about 6 seconds. 
To load the factory defaults, enter the program mode using the procedure on page 24, 
then type [9]-[1]-[0]-[#]. The keypad will beep 3 times to indicate that loading is in 
progress. The loading...

Page 27

         
 
GE Security g 
PROGRAMMING EXAMPLE (Feature selection data) 
 
Security g 
PROGRAMMING EXAMPLE (Feature selection data) 
 
  
Location 23, segment 1 
 
1 = Quick arm 
2 = Re-exit 
3 = Auto bypass 
4 = Silent keypad panic 
5 = Audible keypad panic 
6 = Keypad auxiliary 1 
7 = Keypad auxiliary 2 
8 = Multi-keypad tamper 
 
Press the key on the numeric keypad
 
   
 that corresponds to the feature you wish to 
enable/disable. When a LED is “ON”, a feature is enabled, when “OFF” the feature is...

Page 28

         
 
GE Security g 
Programming the NX-8E control panel via LCD keypad 
ENTERING THE PROGRAM  MODE 
To enter the program mode, press [*]-[8]. The LCD screen will now prompt you for the 
programming code. Next, enter the “Go To Program Code” (FACTORY DEFAULT IS 
9713). If the “Go To Program Code” is valid, the LCD screen will prompt you for the 
device address you wish to program. You are now in the program mode, ready to select 
the module to be programmed.  
Note: it is impossible to enter...

Page 29

         
 
GE Security g 
CHARACTER DATA: Character data is used to enter LCD text when programming (see 
[*]-[9]-[2] feature for custom messages). Custom zone descriptions and messages are 
stored using character or ASCII data types. This information is programmed using the 
bottom line of the display as a text editor. Once a character location has been entered, 
the current data will be displayed on the bottom line. As always, the top line will display 
the current location and segment number. The...

Page 30

         
 
GE Security g 
ALPHANUMERIC CHARACTER TABEL 
1 A 20 T 39 ä 58 n 77 # 
2 B 21 U 40 ä 59 o 78 $ 
3 C 22 V 41 b 60 ô 79 & 
4 D 23 W 42 c 61 ö 80  
5 E 24 X 43 ç 62 p 81 ( 
6 F 25 Y 44 d 63 q 82 ) 
7 G 26 Z 45 e 64 r 83 * 
8 H 27 0 46 é 65 s 84 + 
9 I 28 1 47 è 66 t 85 , 
10 J 29 2 48 ê 67 u 86 - 
11 K 30 3 49 f 68 û 87 . 
12 L 31 4 50 g 69 ü 88 / 
13 M 32 5 51 h 70 v 89 : 
14 N 33 6 52 i 71 w 90 ; 
15 O 34 7 53 î 72 x 91 < 
16 P 35 8 54 j 73 y 92 = 
17 Q 36 9 55 k 74 z 93 > 
18 R 37 a 56 l 75 !...