Page 21
GE Security g [*]-[s] VIEW ZONE STATUS 1. Enter [*]-[s] The LCD screen will display the zone status. 2. Use the ‘up’ and ‘down’ scroll keys to browse through the descriptions. The LCD screen will display the list of ALL zones, in sequential order by zone number. 3. Press [#] to exit this function. [*]-[3] VIEW ALARM MEMORY 1. Enter [*]-[3] The LCD screen will display the zone description for the zones. 2. Use the ‘up’ and ‘down’ scroll keys to browse through the alarm...
Page 22
GE Security g [*]-[6] ASSIGNING AUTHORITY LEVEL Note: You must be authorized to access the partition that you wish to add to, or remove from, another person’s authority. 1. Enter [*]-[6] The LCD screen will prompt for a code. 2. Enter [master code] The LCD screen will prompt for a user number. 3. Enter the 3 digit user number (always 3 digits, i.e. “003” for user 3) The LCD screen will prompt for a new code. The LCD will now prompt you for the first in the following list of...
Page 23
GE Security g [*]-[CHIME] ACTIVATING WALKTEST 1. Enter [*]-[CHIME] The LCD screen will prompt you for a “master code”. 2. Enter [mastercode] The LCD screen will display the “walktest mode” 3. Activate all sensors to test Each activation of a sensor is confirmed with a “ding dong” sound. The zone texts of the sensors who have reacted, are displayed one by one on the screen. 4. Enter [mastercode] The walktest mode is left. Remark: 1. All activations and restore conditions...
Page 24
GE Security g PROGRAMMING THE NX-8E CONTROL PANEL Programming the NX-8E control panel via the LED keypad ENTERING THE PROGRAM MODE To enter the program mode, press [*]-[8]. When you do this, the five function LED’s (Stay, Chime, Exit, Bypass, and Cancel) will begin to flash. Next, enter the “Go To Program Code” (FACTORY DEFAULT IS [9]-[7]-[1]-[3]). If the “Go To Program Code” is valid, the “Service” LED will flash and the five function LED’s will illuminate steadily. You are now in...
Page 25
GE Security g EXITING THE PROGRAM MODE When all the desired changes in programming have been made, it is time to exit the program mode. Press the [Exit] key to exit this programming level, and go to the “Select a Module To Program” level. If no additional modules are to be programmed, press the [Exit] key again to exit the program mode. If there is a module to be programmed, you can select it by entering its address, followed by the [#] key (see “Selecting the Module To Program”...
Page 26
GE Security g Security g LOADING FACTORY DEFAULTS LOADING FACTORY DEFAULTS To load the factory defaults, enter the program mode using the procedure on page 24, then type [9]-[1]-[0]-[#]. The keypad will beep 3 times to indicate that loading is in progress. The loading takes about 6 seconds. To load the factory defaults, enter the program mode using the procedure on page 24, then type [9]-[1]-[0]-[#]. The keypad will beep 3 times to indicate that loading is in progress. The loading...
Page 27
GE Security g PROGRAMMING EXAMPLE (Feature selection data) Security g PROGRAMMING EXAMPLE (Feature selection data) Location 23, segment 1 1 = Quick arm 2 = Re-exit 3 = Auto bypass 4 = Silent keypad panic 5 = Audible keypad panic 6 = Keypad auxiliary 1 7 = Keypad auxiliary 2 8 = Multi-keypad tamper Press the key on the numeric keypad that corresponds to the feature you wish to enable/disable. When a LED is “ON”, a feature is enabled, when “OFF” the feature is...
Page 28
GE Security g Programming the NX-8E control panel via LCD keypad ENTERING THE PROGRAM MODE To enter the program mode, press [*]-[8]. The LCD screen will now prompt you for the programming code. Next, enter the “Go To Program Code” (FACTORY DEFAULT IS 9713). If the “Go To Program Code” is valid, the LCD screen will prompt you for the device address you wish to program. You are now in the program mode, ready to select the module to be programmed. Note: it is impossible to enter...
Page 29
GE Security g CHARACTER DATA: Character data is used to enter LCD text when programming (see [*]-[9]-[2] feature for custom messages). Custom zone descriptions and messages are stored using character or ASCII data types. This information is programmed using the bottom line of the display as a text editor. Once a character location has been entered, the current data will be displayed on the bottom line. As always, the top line will display the current location and segment number. The...
Page 30
GE Security g ALPHANUMERIC CHARACTER TABEL 1 A 20 T 39 ä 58 n 77 # 2 B 21 U 40 ä 59 o 78 $ 3 C 22 V 41 b 60 ô 79 & 4 D 23 W 42 c 61 ö 80 5 E 24 X 43 ç 62 p 81 ( 6 F 25 Y 44 d 63 q 82 ) 7 G 26 Z 45 e 64 r 83 * 8 H 27 0 46 é 65 s 84 + 9 I 28 1 47 è 66 t 85 , 10 J 29 2 48 ê 67 u 86 - 11 K 30 3 49 f 68 û 87 . 12 L 31 4 50 g 69 ü 88 / 13 M 32 5 51 h 70 v 89 : 14 N 33 6 52 i 71 w 90 ; 15 O 34 7 53 î 72 x 91 < 16 P 35 8 54 j 73 y 92 = 17 Q 36 9 55 k 74 z 93 > 18 R 37 a 56 l 75 !...