Page 41

         
 
GE Security g 
Download parameters 
) LOCATION 19 - DOWNLOAD ACCESS CODE (8 segments, numerical data) 
Location 19 contains the eight-digit access code that the NX-8E must receive from the 
downloading software before the panel will allow downloading. The factory default code is 
84800000. 
 
) LOCATION 20 - NUMBER OF RINGS TO ANSWER (1 segment, numerical data) 
Location 20 contains the number of rings to answer for a download. Enter a number from 
“0” (disabled) to “15”. Factory default is...

Page 42

         
 
GE Security g 
 Feature and report selections (for partition 1) 
) LOCATION 23 - PARTITION 1, FEATURE AND REPORT SELECTIONS (5 segments, feature     
selection data) 
Location 23 is used to enable certain features that the user can access or see from the 
keypad of the system. In addition, certain communicator reports are enabled in location 
23. Each of these features can be enabled by partition. For additional partition 
information, see locations 88-109. 
If the feature selection location...

Page 43

         
 
GE Security g 
 
Segment 5 1 = Reserved 
 2 = Reserved 
 3 = Reserved 
 4 = Reserved 
 5 = Reserved 
 6 = Reserved 
 7 = Reserved 
 8 = Reserved 
 
 
Entry/Exit timers 
) LOCATION 24 - ENTRY / EXIT TIMERS (6 segments, numerical data) 
Location 24 is used to program the entry/exit times. There are 2 separate entry/exit times. 
Segment 1 Entry time 1 This is the entry time that will be used when a delay 
1 zone type initiates an entry delay. 
Valid entries are 10-255 seconds. 
 
Segment 2...

Page 44

         
 
GE Security g 
Zone configurations and partition selection 
DEFAULT ZONE CONFIGURATIONS 
Zones can be programmed to be one of thirty different zone configurations (zone types). 
The default zone configurations are listed below. Programming locations 110-169 can 
customise all zone configurations.  
  
DATA R conf. DESCRIPTION OF DEFAULT CONFIGURATION 
1 1 DAY ZONE  
Instant when system is armed; trouble zone when system is disarmed. A day zone will 
only work if programmed for single...

Page 45

         
 
GE Security g 
 
12 2 INTERIOR FOLLOWER WITH “CROSS ZONE” ENABLED  
This zone will be instant when the system is armed and no entry or exit delay is being 
timed. It is delayed during entry and exit delay times. If a “Cross Zone” is not being 
timed, it will start a “Cross Zone” timer. If a “Cross Zone” is being timed, it will create an 
instant alarm. This zone will bypass automatically, when enabled in segment 1 of 
location 23. 
13 2 INSTANT ENTRY GUARD 
This zone creates an instant alarm...

Page 46

         
 
GE Security g 
 
24 2 INSTANT ZONE WITH CHIME ENABLED 
A trip will create an alarm when the system is armed. When the control panel is 
disarmed and the chime mode has been set, this zone will act as a chime zone. 
25 2 FOLLOWER ZONE WITH CHIME ACTIVATED 
This zone will be instant when the system is armed and no entry or exit delays are being 
timed. It is delayed during entry and exit delay times. This zone will not bypass 
automatically, even if enabled in segment 1 of location 23. When...

Page 47

         
 
GE Security g 
) LOCATION 25 - ZONES 1-8 CONFIGURATION GROUP (8 segments, numerical data) 
Location 25 contains the configuration group (zone type) for zones 1-8. Segment 1 is for 
zone 1, and segment 8 is for zone 8. You will find the default configurations in the table 
above. 
 
LOCATION 26 - PARTITION SELECT, ZONES 1-8 (8 segments, feature selection data) 
Location 26 is used to select the partition(s) in which zones 1 - 8 reside. A zone may 
reside in any combination of the 8...

Page 48

         
 
GE Security g 
) LOCATION 29 - ZONES 17-24 CONFIGURATION GROUP (8 segments, numerical data) 
Location 29 contains the configuration group (zone type) for zones 17-24. Segment 1 is 
for zone 17, segment 8 is for zone 24. You will find the default configurations in the table 
above. 
 
LOCATION 30 - PARTITION SELECT, ZONES 17-24 (8 segments, feature selection data) 
Location 30 is used to select the partition(s) in which zones 17-24 reside. A zone may 
reside in any combination of the 8...

Page 49

         
 
GE Security g 
) LOCATION 33 - ZONES 33-40 CONFIGURATION GROUP (8 segments, numerical data) 
Location 33 contains the configuration group (zone type) for zones 33-40. Segment 1 is 
for zone 33, and segment 8 is for zone 40. You will find the default configurations in the 
table above. 
 
LOCATION 34 - PARTITION SELECT, ZONES 33-40 (8 segments of feature selection data) 
Location 34 is used to select the partition(s) in which zones 33-40 reside. A zone may 
reside in any combination of the 8...

Page 50

         
 
GE Security g 
General options 
LOCATION 37 - SIREN AND SYSTEM SUPERVISION (7 segments, feature selection data) 
Location 37 is used to enable various system feature and reporting options.  
Segment 1 1 = On: if siren sounds for “Telephone Line Cut” when armed 
 2 = On: if siren sounds for “Telephone Line Cut” when disarmed 
 3 = On: if siren blast at arming (pulse) 
 4 = On: if siren blast at exit expiration (pulse) 
 5 = On: if siren blast at closing kiss-off (pulse) 
 6 = On: if siren...