GE Security g Download parameters ) LOCATION 19 - DOWNLOAD ACCESS CODE (8 segments, numerical data) Location 19 contains the eight-digit access code that the NX-8E must receive from the downloading software before the panel will allow downloading. The factory default code is 84800000. ) LOCATION 20 - NUMBER OF RINGS TO ANSWER (1 segment, numerical data) Location 20 contains the number of rings to answer for a download. Enter a number from “0” (disabled) to “15”. Factory default is...
Page 42
GE Security g Feature and report selections (for partition 1) ) LOCATION 23 - PARTITION 1, FEATURE AND REPORT SELECTIONS (5 segments, feature selection data) Location 23 is used to enable certain features that the user can access or see from the keypad of the system. In addition, certain communicator reports are enabled in location 23. Each of these features can be enabled by partition. For additional partition information, see locations 88-109. If the feature selection location...
Page 43
GE Security g Segment 5 1 = Reserved 2 = Reserved 3 = Reserved 4 = Reserved 5 = Reserved 6 = Reserved 7 = Reserved 8 = Reserved Entry/Exit timers ) LOCATION 24 - ENTRY / EXIT TIMERS (6 segments, numerical data) Location 24 is used to program the entry/exit times. There are 2 separate entry/exit times. Segment 1 Entry time 1 This is the entry time that will be used when a delay 1 zone type initiates an entry delay. Valid entries are 10-255 seconds. Segment 2...
Page 44
GE Security g Zone configurations and partition selection DEFAULT ZONE CONFIGURATIONS Zones can be programmed to be one of thirty different zone configurations (zone types). The default zone configurations are listed below. Programming locations 110-169 can customise all zone configurations. DATA R conf. DESCRIPTION OF DEFAULT CONFIGURATION 1 1 DAY ZONE Instant when system is armed; trouble zone when system is disarmed. A day zone will only work if programmed for single...
Page 45
GE Security g 12 2 INTERIOR FOLLOWER WITH “CROSS ZONE” ENABLED This zone will be instant when the system is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. If a “Cross Zone” is not being timed, it will start a “Cross Zone” timer. If a “Cross Zone” is being timed, it will create an instant alarm. This zone will bypass automatically, when enabled in segment 1 of location 23. 13 2 INSTANT ENTRY GUARD This zone creates an instant alarm...
Page 46
GE Security g 24 2 INSTANT ZONE WITH CHIME ENABLED A trip will create an alarm when the system is armed. When the control panel is disarmed and the chime mode has been set, this zone will act as a chime zone. 25 2 FOLLOWER ZONE WITH CHIME ACTIVATED This zone will be instant when the system is armed and no entry or exit delays are being timed. It is delayed during entry and exit delay times. This zone will not bypass automatically, even if enabled in segment 1 of location 23. When...
Page 47
GE Security g ) LOCATION 25 - ZONES 1-8 CONFIGURATION GROUP (8 segments, numerical data) Location 25 contains the configuration group (zone type) for zones 1-8. Segment 1 is for zone 1, and segment 8 is for zone 8. You will find the default configurations in the table above. LOCATION 26 - PARTITION SELECT, ZONES 1-8 (8 segments, feature selection data) Location 26 is used to select the partition(s) in which zones 1 - 8 reside. A zone may reside in any combination of the 8...
Page 48
GE Security g ) LOCATION 29 - ZONES 17-24 CONFIGURATION GROUP (8 segments, numerical data) Location 29 contains the configuration group (zone type) for zones 17-24. Segment 1 is for zone 17, segment 8 is for zone 24. You will find the default configurations in the table above. LOCATION 30 - PARTITION SELECT, ZONES 17-24 (8 segments, feature selection data) Location 30 is used to select the partition(s) in which zones 17-24 reside. A zone may reside in any combination of the 8...
Page 49
GE Security g ) LOCATION 33 - ZONES 33-40 CONFIGURATION GROUP (8 segments, numerical data) Location 33 contains the configuration group (zone type) for zones 33-40. Segment 1 is for zone 33, and segment 8 is for zone 40. You will find the default configurations in the table above. LOCATION 34 - PARTITION SELECT, ZONES 33-40 (8 segments of feature selection data) Location 34 is used to select the partition(s) in which zones 33-40 reside. A zone may reside in any combination of the 8...
Page 50
GE Security g General options LOCATION 37 - SIREN AND SYSTEM SUPERVISION (7 segments, feature selection data) Location 37 is used to enable various system feature and reporting options. Segment 1 1 = On: if siren sounds for “Telephone Line Cut” when armed 2 = On: if siren sounds for “Telephone Line Cut” when disarmed 3 = On: if siren blast at arming (pulse) 4 = On: if siren blast at exit expiration (pulse) 5 = On: if siren blast at closing kiss-off (pulse) 6 = On: if siren...