Page 11
GE Security g Start/end programming and end downloading A report can be sent when local programming is started and ended. A report can also be sent when a download session ends (see location 37 segment 4). Swinger shutdown This feature allows one or more zones to be bypassed automatically after a specified number of alarms. If immediate restore is enabled in location 37, the alarms (and restores, if this option is enabled) will be sent as they occur. If immediate restore is not...
Page 12
GE Security g PROGRAMMING THE NX-8E KEYPADS Programming the NX-8E LED keypads This section describes how to program the address and partition for each keypad, and it also explains the options that are available. The address of the keypad is important because the panel uses it to supervise the keypads. The factory default for the master code is [1]-[2]-[3]-[4] when using a 4-digit code, or [1]- [2]-[3]-[4]-[5]-[6] for a 6-digit code. The factory default for the “Go To Program” code...
Page 13
GE Security g [*]-[9]-[4] SET KEYPAD NUMBER AND PARTITION 1. Enter [*]-[9]-[4]-[program code]- the “Service” LED and the “Instant” LED will flash. 2. Enter the keypad number (1-8). 3. Press [*]- the “Instant” LED will illuminate steadily, and the “Service” LED will carry on flashing. 4. Enter the partition number for the keypad. The keypad will automatically exit this mode now). [*]-[9]-[5] SET ELAPSED INCREMENTS (HOURS/DAYS) SINCE LAST AUTOTEST 1. Enter...
Page 14
GE Security g [*]-[5] CHANGING USER CODES 1. Enter [*]-[5]-[master code]- the “Ready” LED will flash. 2. Enter the 3 digit user number (always 3 digits, such as “003” for user 3)- the “Ready” LED will illuminate steadily. 3. Enter the new user code designated for the person in question - the “Ready” LED will flash, indicating that the code has been accepted. If the code is rejected, the sounder will beep 3 times. 4. If another user code needs to be programmed, return to step...
Page 15
GE Security g NOTE: ANY MASTER ARM/DISARM CODE CAN ADD OR CHANGE A USER CODE IF THE MASTER CODE HAS ACCESS TO THE SAME PARTITIONS AS THE CODE BEING ADDED/CHANGED. CONSEQUENTLY, WHEN PROGRAMMING THE USER CODES FOR A PARTITIONED SYSTEM, LEAVE AT LEAST ONE CODE WITH ACCESS TO ALL PARTITIONS. UNLESS YOU DO THIS, YOU WILL NOT BE ABLE TO ADD NEW USERS. (THE CODE CAN BE THE “GO TO PROGRAM CODE”, IF ENABLED IN LOCATION 43). IF YOU WANT TO LET THE END USER ADD NEW CODES, YOU MUST REMOVE THE...
Page 16
GE Security g Programming the NX-148 LCD keypads This section describes how to program the address and partition for each keypad, and it also explains the options that are available. The address of the keypad is important because the panel uses it to supervise the keypads. The factory default for the Master code is [1]-[2]-[3]-[4] when using a 4-digit code, or [1]- [2]-[3]-[4]-[5]-[6] for a 6-digit code. The factory default for the “Go To Program” code is [9]-[7]-[1]-[3] when using a...
Page 17
GE Security g [*]-[9]-[3] SET KEYPAD OPTIONS 1. Enter [*]-[9]-[3] The LCD screen will prompt for a code. 2. Enter [program code] The LCD will now prompt you through the options listed in the following chart. The current state of the option will be shown in the lower right corner of the display. Press [*] to exit the current state without any changes. Otherwise, follow the directions on the bottom line to select the desired option. When finished, press [*] to move to the next...
Page 18
GE Security g Remark : In the menu “Select an option” 8 additional options can be selected. The options 5 until 8 are not used for the moment and may therefore not be selected. The options 1 and 4 are described below: Option 1 : On the LCD screen “press * for help”. By this the status of the system and the message “press * for help” are alternately displayed on the LCD screen. This is only to inform the user of the user’s menu. Option 2 : Light continuously on. By this the lights of...
Page 19
GE Security g Keypad functions for the NX-148 LCD keypad The LCD keypads have a bilingual user’s interface. As a result, you can simply select a user’s function on the menu. You can consult the menu by entering the [*] key. The user of the system can easily switch from one user’s interface to another and the other way around. To select a user’s function, following steps have to be performed. Step 1 Enter the [*] key until the function you want, appears on the LCD display / screen....
Page 20
GE Security g [*]-[9]-[0] READING THE EVENT LOG [*]-[9]-[0] READING THE EVENT LOG The NX-8E has a 512-event log which can be retrieved using a master code. This log contains a listing of the last 512 events along with the date, time, and partition where each event occurred. The NX-8E has a 512-event log which can be retrieved using a master code. This log contains a listing of the last 512 events along with the date, time, and partition where each event occurred. 1. 1. Press...