Page 51
GE Security g Segment 5 1 = On: enable lost clock service light 2 = On: use of wireless and hardwired zones together on zones 1-8 only 3 = On: disables on-board 8 zones 4 = On: will allow two trips on same cross-zone to activate an alarm 5 = On: will not allow zones that are force armed to report bypass 6 = On: enables silent exit option 7 = On: activate “first disarm reporting” - “last arm reporting” for partitions 8 = On: switch “summer/wintertime” and vice versa...
Page 52
GE Security g LOCATION 40 - SYSTEM TIMERS (14 segments, numerical data) Location 40 contains the duration of various system timing functions. Example: If you want the duration of the dynamic battery test to be 30 minutes, you should program [3]- [0]-[*] in segment 1 of this location. The [3]-[0] is the number of minutes; the [*] stores the data, and moves to the next segment of this location. Segment 1 Dynamic battery test duration in minutes, 0-255 minutes (“0” = no test) Segment 2...
Page 53
GE Security g LOCATION 43 - GO TO PROGRAM CODE PARTITION AND AUTHORIZATION (2 segments, feature selection data) The “Go To Program Code” can be used as a standard arm/disarm code. When using the code to arm or disarm, the user ID is 255. (It is not possible to change this code in the run mode). Segment 1 1 = Reserved 2 = On: enables “Go To Program Code” as an arm only code 3 = On: enables “Go To Program Code” as an arm only, after closing 4 = On: enables “Go To Program Code” as...
Page 54
GE Security g Programming the outputs LOCATION 45 - AUXILIARY OUTPUT 1-4 PARTITION SELECTION (4 segments, feature selection data) Location 45 is used to select the partition(s) in which the events must occur before the output (relay) will activate. Location 45 has 4 segments. Segment 1 corresponds to output 1, and segment 2 corresponds to output 2, segments 3 and 4 correspond to outputs 3 and 4. Segment 1 (Auxiliary 1) Segment 2 (Auxiliary 2) Segment 3 (Auxiliary) Segment 4...
Page 55
GE Security g LOCATION 48 - AUXILIARY OUTPUT 2 (relay 2 and open collector 2), EVENT AND TIME (2 segments, numerical data) Segment 1 Use the chart below to select the event that will activate auxiliary output 2 (relay 2) Segment 2 Program the timing from 0-255 (minutes or seconds, depending on the data programmed in segment 2, location 46). Programming a “0” makes the output follow the event LOCATION 49- AUXILIARY OUTPUT 3 (open collector 3), EVENT AND TIME (2 segments, numerical...
Page 56
GE Security g AUXILIARY OUTPUT EVENT SELECTION DATA EVENT DATA EVENT 04 Burglary alarm 27 Chime 14 Fire alarm 284 Expander trouble 24 24 hour alarm 29 Dynamic battery test time 34 Trouble alarm 30 Open period 4 Tamper alarm 31 Closed period 5 Yelping siren 32 Listen-in 6 Steady siren 33 Line seizure 7 Any siren 34 Reserved 8 Any bypass 35 Fail to communicate 9 AC fail 36 Telephone line fault 10 Low battery 37 Program mode 114 Duress 38 Download in process 124 Aux 1 keypad...
Page 57
GE Security g Setup for auto-test, auto-arm and opening/closing times LOCATION 51 - AUTOTEST CONTROL (4 segments, numerical data) Segment 1 Program a “1” if the interval is to be in hours; program a “0” for days. Add a “2” to suppress the daily test or a “3” to suppress the hourly test if any report has been sent Segment 2 Program the autotest interval from 1-255 hours/days Segment 3 Program the autotest report hour in 24 hour format (if the interval is in hours, this segment Is...
Page 58
GE Security g LOCATION 54 - DAYS OF THE WEEK “ARM ONLY AFTER CLOSE WINDOW” CODES FUNCTION IN PARTITIONS 1 THRU 8 (8 Segments, feature selection data) Location 54 selects the days of the week on which each partition is open. On these days, “arm only after close window” codes will be able to arm and disarm during “open window”. On days not selected here, “arm only after close window” codes will not disarm. Segment 1 is for partition 1, and segment 8 is for partition 8 (see locations 52...
Page 59
GE Security g Communicator codes for slow speed formats only LOCATIONS 56-83 ARE ONLY USED WHEN REPORTING EVENTS TO A PAGER, OR WHEN USING A SLOW FORMAT SUCH AS 4+2. WHEN USING CONTACT ID OR SIA, THERE IS NO NEED TO PROGRAM THESE LOCATIONS. LOCATION 56 - RESTORE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical data) Location 56 contains the event code for a zone “Restore” for a 4+2 and 3+1 format. For a 4+2 format, the digit programmed in this location will be sent...
Page 60
GE Security g LOCATION 58 - TAMPER COMMUNICATOR CODE, SLOW SPEED FORMATS (8 segments, numerical data) Location 58 contains the event code for a zone “Tamper” with a 4+2 and 3+1 format. For a 4+2 format, the digit programmed in this location will be sent as the tens digit of the tamper event code. The zone ID will always be reported as the ones digit of the zone number (e.g. zone 16 = 6, zone 45 = 5). This location contains 8 segments. Any segment left as “0” will follow the segment 1...