GE Security g CONTENTS CONTENTS........................................................................\ .................................................................................................2 GENERAL INFORMATION........................................................................\ .....................................................................4 ORDERING INFORMATION........................................................................\...
Page 3
GE Security g NX-8E PROGRAMMING WORKSHEETS........................................................................\ ...........................................94 BOARD INSTALLATION........................................................................\ .....................................................................115 NX-8E WIRING DIAGRAM........................................................................\ ..................................................................116...
Page 4
GE Security g GENERAL INFORMATION The NX-8E NetworX from Caddx represents a new approach to the design of security systems. The NX-8E is probably the most flexible, durable, and user-friendly control panel ever seen in our industry. Its features include sophisticated software enabling as many as 240 users to interface up to 192 zones, 8 partitions, with access, audio verification, and input/output modules, all reported with SIA and Contact ID formats which are extremely fast and...
Page 5
GE Security g FEATURE DEFINITIONS Abort If this option is enabled, the NX-8E will wait the programmed number of seconds (0-255) in location 40 prior to sending an alarm. During this delay time, the “Cancel” LED will flash. To abort the report, type in a code and press the [Cancel] key. The LED will go out. If the report is not aborted within the allotted time, the LED will go out when the report is sent. The dialler delay is programmed at location 40, segment 8. Each zone can be...
Page 6
GE Security g Auxiliary power overcurrent The NX-8E will light up the “Service” LED on the keypad whenever too much current is being drawn from any device powered by the system. This condition can be reported to the central station (see location 37 segment 3). Box tamper The NX-8E has an input for a normally closed tamper switch (see wiring diagram). The box tamper can be programmed to report, and/or sound the siren and/or the keypad. These terminals can be enabled or disabled by...
Page 7
GE Security g Cross zoning This feature requires two or more trips within a specified time on one or more zones that are programmed as “cross zones” before it will report an alarm. During the time between trips, the NX-8E can be programmed to sound the keypad and/or the siren. The NX-8E can also be programmed to report an alarm after two or more trips on the same zone. The first trip on a cross-zone is also logged (see locations 37 segment 1, 39, 40 and 110-169). Daylight savings...
Page 8
GE Security g Expander trouble The NX-8E will report expander trouble to the central station if this option is enabled. This condition will light up the “Service” LED on the keypad, even if it is not reported. NOTE: The keypads are considered to be expanders. The number of expansion devices that are reported can be found in appendix 3 (see location 37 segment 3). Early to Open/ Late to Close If an opening occurs before the opening and closing times, the NX-8E will send an “Early...
Page 9
GE Security g Immediate restore by zone The NX-8E can be programmed to send alarm and restore reports as soon as they occur, or to wait until the siren time has expired or the system has been disarmed. (see location 37 segment 2). Internal event log Up to 512 events can be stored in memory together with the date and time of the event. These events can be viewed later on via the LCD keypad, or by downloading. All reportable events are reported to the log. Keypad activated panics...
Page 10
GE Security g Manual test The NX-8E can be programmed to perform a bell and/or communicator test; to do this, enter [*]-[4]-[4] while the system is in the disarmed state. Each time that [*]-[4]-[4] is entered, a dynamic battery test will also be performed (see location 37 segment 2). Night Mode Applies to NX-1208E / NX-1248E keypads. In this mode, the control panel will bypass all zones that have the Entry Guard feature enabled. (See location 23 and 111-169) On board zone disable...