GE Nx 8 Manual
Have a look at the manual GE Nx 8 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 GE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
GE Security g Download parameters ) LOCATION 19 - DOWNLOAD ACCESS CODE (8 segments, numerical data) Location 19 contains the eight-digit access code that the NX-8E must receive from the downloading software before the panel will allow downloading. The factory default code is 84800000. ) LOCATION 20 - NUMBER OF RINGS TO ANSWER (1 segment, numerical data) Location 20 contains the number of rings to answer for a download. Enter a number from “0” (disabled) to “15”. Factory default is “8”, so the NX-8E will answer after 8 rings. LOCATION 21 - DOWNLOAD CONTROL (1 segment, feature selection data) Location 21 contains the feature selections to control download sessions. The following features can be enabled or disabled using this location (see the feature definitions on pages 5-11). Segment 1 1 = On: enables two call answering machine defeat 2 = Reserved 3 = On: requires call-back before download session 4 = Shutdown (can only be viewed from the keypad; must be changed by downloading) 5 = On: locks all local programming. (can only be viewed from the keypad; must be changed by downloading) 6 = On: locks programming of all locations associated with the communicator (can only be viewed from the keypad; must be changed by downloading) 7 = On: locks out download section. (If “On”, locations 19-22 cannot be viewed from the keypad; can only be viewed from the keypad when “Off”.) 8 = On: enables call-back at auto test interval LOCATION 22 - DOWNLOAD CALL BACK NUMBER (20 segments, numerical data) If a telephone number is programmed into this location, and “Require Call-back” is enabled in location 21, the control panel will hang up for approximately 36 seconds (ensuring that the calling party has disconnected), and then call back. The system will always wait for a dial tone unless the first digit of the phone number is a “13”; in this case, it will only delay. Tone (DTMF) dialling is default. If you want pulse tone dialling, program a “15” in the segment where pulse dialling should begin. If the entire number should be pulse dialling, program a “15” in the first segment. Four-second delays can be obtained anywhere in the sequence by programming a “13” in the appropriate delay location. Note: a zero is programmed as a “0”. WARNING: YOU SHOULD ALWAYS CHECK THAT THE CALLBACK PHONE NUMBER IS ACCURATE BEFORE DISCONNECTING. NX-8E Installation manual Page 41 Date 08/09/04
GE Security g Feature and report selections (for partition 1) ) LOCATION 23 - PARTITION 1, FEATURE AND REPORT SELECTIONS (5 segments, feature selection data) Location 23 is used to enable certain features that the user can access or see from the keypad of the system. In addition, certain communicator reports are enabled in location 23. Each of these features can be enabled by partition. For additional partition information, see locations 88-109. If the feature selection location for any partition is left blank, that partition will use this location for the feature selection. This location contains 5 segments of 8 features each (see the feature definitions). Segment 1 1 = On: enables the quick arm feature (for exit and stay mode) 2 = On: enables the re-exit feature 3 = On: enables the automatic bypass feature (of interior zones) 4 = On: enables the silent keypad panic feature (overrides the audible panic selection) 5 = On: enables the audible keypad panic feature 6 = On: enables the keypad Aux 1 feature (FIRE) 7 = On: enables the keypad Aux 2 feature (MEDICAL) 8 = On: enables the keypad multiple code attempt tamper feature (keypad lockout) Segment 2 1 = On: enables the LED extinguish feature 2 = On: enables the require code for bypassing feature 3 = On: enables the zone bypassed sounder alert feature 4 = On: enables the AC power/low battery sounder alert feature 5 = On: enables bypass toggle 6 = On: enables silent auto arm 7 = On: enables the automatic instant feature (of entry/exit zones) 8 = On: enables final set door Segment 3 1 = On: enables opening and closing reports 2 = On: enables zone bypass reporting 3 = On: enables zone restore reporting 4 = On: enables zone trouble reporting 5 = On: enables zone tamper reporting 6 = On: enables the cancel reporting 7 = On: enables the recent closing report 8 = On: enables the exit error report Segment 4 1 = On: enables late to close / early to open reporting 2 = On: enables auto arm in STAY mode 3 = On: enables instant NIGHT mode (applies to NX-1208E / NX- 1248E: no toggle) 4 = On: tamper when sensor lost if armed 5 = On : enables instant STAY mode (toggle) 6 = Reserved 7 = Reserved 8 = Reserved NX-8E Installation manual Page 42 Date 08/09/04
GE Security g Segment 5 1 = Reserved 2 = Reserved 3 = Reserved 4 = Reserved 5 = Reserved 6 = Reserved 7 = Reserved 8 = Reserved Entry/Exit timers ) LOCATION 24 - ENTRY / EXIT TIMERS (6 segments, numerical data) Location 24 is used to program the entry/exit times. There are 2 separate entry/exit times. Segment 1 Entry time 1 This is the entry time that will be used when a delay 1 zone type initiates an entry delay. Valid entries are 10-255 seconds. Segment 2 Entry time 2 This is the exit time that will be used for all zones designated as delay 1. Valid entries are 10-255 seconds. Segment 3 Entry time 3 This is the entry time that will be used when a delay 2 zone type initiates an entry delay. Valid entries are 10-255 seconds. Segment 4 Entry time 4 This is the exit time that will be used for all zones designated as delay 2. Valid entries are 10-255 seconds. Segment 5 Reserved Segment 6 Reserved NX-8E Installation manual Page 43 Date 08/09/04
GE Security g Zone configurations and partition selection DEFAULT ZONE CONFIGURATIONS Zones can be programmed to be one of thirty different zone configurations (zone types). The default zone configurations are listed below. Programming locations 110-169 can customise all zone configurations. DATA R conf. DESCRIPTION OF DEFAULT CONFIGURATION 1 1 DAY ZONE Instant when system is armed; trouble zone when system is disarmed. A day zone will only work if programmed for single end-of-line resistor. 2 2 24 HOUR AUDIBLE Creates an instant yelping siren alarm regardless of the arming state of the control panel. This zone type is not abortable. This zone can be bypassed. 3 2 ENTRY/EXIT DELAY 1 A trip will start entry delay 1. Absence of a trip during the exit delay will enable the Automatic Bypass or Instant mode, if so programmed. 4 2 FOLLOWER (WITH AUTO- BYPASS DISABLED) This zone will be instant when the system is armed and no entry or exit delays are being timed. It is delayed during entry and exit delay times. This zone will not bypass automatically, even if enabled in segment 1 of location 23. 5 2 INTERIOR FOLLOWER (WITH AUTO- BYPASS ENABLED) This zone will be instant when the system is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. This zone will bypass automatically, if enabled in segment 1 of location 23. 6 2 INSTANT This zone creates an instant alarm whenever it is tripped and the armed LED is on. 7 2 24 HOUR SILENT Creates an instant silent alarm regardless of the arming state of the control panel. It will not display on the keypad. This zone is not abortable, but can be bypassed. 8 1 FIRE This zone will light up the fire LED and sound the steady siren each time the zone is shorted. It will also rapidly flash the fire LED, indicating trouble if the zone is open. This zone cannot be bypassed. 9 2 ENTRY/EXIT DELAY 2 A trip will start entry delay 2. Absence of a trip during the exit delay will enable the automatic bypass or instant mode, if so programmed. 10 1 24 HOUR AUDIBLE SUPERVISED Creates an instant audible alarm, regardless of the arming state of the control panel. It will display on the keypad (e.g. flashing zone LED’s, and changed READY LED). This zone is not abortable and cannot be bypassed. 11 2 MOMENTARY KEYSWITCH ZONE This zone type will arm and disarm the partition or partitions of the control panel where it is resident, every time the zone is shorted. Keyswitch arming will report as user 99. This zone type can only belong to 1 partition. NX-8E Installation manual Page 44 Date 08/09/04
GE Security g 12 2 INTERIOR FOLLOWER WITH “CROSS ZONE” ENABLED This zone will be instant when the system is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. If a “Cross Zone” is not being timed, it will start a “Cross Zone” timer. If a “Cross Zone” is being timed, it will create an instant alarm. This zone will bypass automatically, when enabled in segment 1 of location 23. 13 2 INSTANT ENTRY GUARD This zone creates an instant alarm whenever it is tripped and the stay/instant LED is off. It will start an entry delay time 1 if it is tripped, provided that the system is armed and the stay/instant LED is on. 14 2 ENTRY/EXIT DELAY 1 WITH GROUP BYPASS ENABLED A trip will start entry delay 1. This zone will bypass when the “Group Bypass” command is entered at the keypad. Absence of a trip during exit delay will enable the automatic bypass or instant mode, if so programmed. 15 2 INTERIOR FOLLOWER WITH GROUP BYPASS ENABLED This zone will be instant when the system is armed and no entry or exit delays are being timed. It is delayed during entry/exit delay times. This zone will bypass when the “Group Bypass” command is entered at the keypad. This zone will bypass automatically, if enabled in segment 1 of location 23. 16 2 INSTANT WITH GROUP BYPASS ENABLED This zone creates an instant alarm whenever it is tripped and the armed LED is on. This zone will bypass when the “Group Bypass” command is entered at the keypad 17 2 MAINTAINED KEYSWITCH This zone type will arm the partition or partitions of the control panel where it is resident, as long as the zone is shorted. This zone type will disarm the partition or partitions of the control where it is resident, as long as the zone is open. Keyswitch arming will report as user 99. 18 2 ENTRY/EXIT DELAY 1 FORCE ARMABLE A trip will start entry delay 1. Absence of a trip during exit delay will enable the automatic bypass or instant mode, if so programmed. This zone is force armable (see feature definitions pages 5-11). 19 2 ENTRY/EXIT DELAY 2 FORCE ARMABLE A trip will start entry delay 2. Absence of a trip during exit delay will enable the automatic bypass or instant mode, if so programmed. This zone is force armable (see feature definitions, pages 5-11). 20 2 ENTRY/EXIT DELAY 1 WITH CHIME ENABLED A trip will start entry delay 1. Absence of a trip during exit delay will enable the automatic bypass or instant mode, if so programmed. When the control panel is disarmed and the chime mode has been set, this zone will act as a chime zone. 21 2 TECHNICAL ALARM, SUPERVISED, AUDIBLE Any trip on a technical zone creates an audible alarm, regardless of the arming state of the control panel. This zone can be bypassed. 22 2 TECHNICAL ALARM, SUPERVISED, SILENCE Any trip on a silent technical zone creates a silent alarm, regardless of the arming state of the control panel. Only the transmitter will be activated. This zone can be bypassed. 23 2 INTERIOR INSTANT ZONE This zone creates an instant alarm whenever it is tripped during the arming state of the control panel. This zone will bypass automatically, if enabled in segment 1 of location 23, or when ths system is armed in the “Stay” mode. NX-8E Installation manual Page 45 Date 08/09/04
GE Security g 24 2 INSTANT ZONE WITH CHIME ENABLED A trip will create an alarm when the system is armed. When the control panel is disarmed and the chime mode has been set, this zone will act as a chime zone. 25 2 FOLLOWER ZONE WITH CHIME ACTIVATED This zone will be instant when the system is armed and no entry or exit delays are being timed. It is delayed during entry and exit delay times. This zone will not bypass automatically, even if enabled in segment 1 of location 23. When the control panel is disarmed and the chime mode has been set, this zone will act as a chime zone. 26 2 24 HOUR, AUDIBLE, SUPERVISED, LOCAL Creates an instant audible alarm, regardless of the arming state of the control panel. It will display on the keypad (e.g. flashing zone LED’s, and changed READY LED). This zonetype will NOT be reported. 27 2 INSTANT ZONE FORCE ARMABLE This zone creates an instant alarm whenever the system is armed. This zone is force armable (see feature definitions, pages 5-11). 28 2 INSTANT ZONE ACTIVITY MONITOR ENABLED This zone creates an instant alarm whenever the system is armed. It will send a report if the zone activity time is reached without a change of state (see location 40, segment 11 and locations 110-169). 29 INSTANT ZONE WITH END OF LINE RESISTOR DEFEAT This zone creates an instant alarm whenever the system is armed. When the loop is closed, the zone is ready. Opening of the loop means a faulted zone (see locations 110- 169). 30 2 24 HOUR, MEDICAL, AUDIBLE, SUPERVISED Creates an instant audible alarm, regardless of the arming state of the control panel. It will display on the keypad (e.g. flashing zone LED’s, and changed READY LED). A medical report will be sent to the CMS. Note: all zone configurations are programmed for double end of line resistor configuration, except for DAY ZONE, FIRE, 24H AUDIBLE SUPERVISED and END OF LINE RESISTOR DEFEAT. NX-8E Installation manual Page 46 Date 08/09/04
GE Security g ) LOCATION 25 - ZONES 1-8 CONFIGURATION GROUP (8 segments, numerical data) Location 25 contains the configuration group (zone type) for zones 1-8. Segment 1 is for zone 1, and segment 8 is for zone 8. You will find the default configurations in the table above. LOCATION 26 - PARTITION SELECT, ZONES 1-8 (8 segments, feature selection data) Location 26 is used to select the partition(s) in which zones 1 - 8 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 1, and segment 8 corresponds to zone 8. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 ) LOCATION 27 - ZONES 9-16 CONFIGURATION GROUP (8 segments, numerical data) Location 27 contains the configuration group (zone type) for zones 9 -16. Segment 1 is for zone 9, and segment 8 is for zone 16. You will find the default configurations in the table above. LOCATION 28 - PARTITION SELECT, ZONES 9-16 (8 segments, feature selection data) Location 28 is used to select the partition(s) in which zones 9-16 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions are armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Location 28 has 8 segments. Segment 1 corresponds to zone 9 and Segment 8 corresponds to zone 16. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 NX-8E Installation manual Page 47 Date 08/09/04
GE Security g ) LOCATION 29 - ZONES 17-24 CONFIGURATION GROUP (8 segments, numerical data) Location 29 contains the configuration group (zone type) for zones 17-24. Segment 1 is for zone 17, segment 8 is for zone 24. You will find the default configurations in the table above. LOCATION 30 - PARTITION SELECT, ZONES 17-24 (8 segments, feature selection data) Location 30 is used to select the partition(s) in which zones 17-24 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions are armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Location 30 has 8 segments. Segment 1 corresponds to zone 17 and segment 8 corresponds to zone 24. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 ) LOCATION 31 - ZONES 25-32 CONFIGURATION GROUP (8 segments, numerical data) Location 31 contains the configuration group (zone type) for zones 25-32. Segment 1 is for zone 25, segment 8 is for zone 32. You will find the default configurations in the table above. LOCATION 32 - PARTITION SELECT, ZONES 25-32 (8 segments, feature selection data) Location 32 is used to select the partition(s) in which zones 25-32 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions are armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1 corresponds to zone 25 and segment 8 corresponds to zone 32. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 NX-8E Installation manual Page 48 Date 08/09/04
GE Security g ) LOCATION 33 - ZONES 33-40 CONFIGURATION GROUP (8 segments, numerical data) Location 33 contains the configuration group (zone type) for zones 33-40. Segment 1 is for zone 33, and segment 8 is for zone 40. You will find the default configurations in the table above. LOCATION 34 - PARTITION SELECT, ZONES 33-40 (8 segments of feature selection data) Location 34 is used to select the partition(s) in which zones 33-40 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions are armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1 corresponds to zone 33 and segment 8 corresponds to zone 40. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 LOCATION 35 - ZONES 41-48 CONFIGURATION GROUP (8 segments of numerical data) Location 35 contains the configuration group (zone type) for zones 41-48. Segment 1 is for zone 41, and segment 8 is for zone 48. You will find the default configurations in the table above. LOCATION 36 - PARTITION SELECT, ZONES 41-48 (8 segments, feature selection data) Location 36 is used to select the partition or partitions in which zones 41-48 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions are armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Location 36 has 8 segments. Segment 1 corresponds to zone 41 and segment 8 corresponds to zone 48. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 NX-8E Installation manual Page 49 Date 08/09/04
GE Security g General options LOCATION 37 - SIREN AND SYSTEM SUPERVISION (7 segments, feature selection data) Location 37 is used to enable various system feature and reporting options. Segment 1 1 = On: if siren sounds for “Telephone Line Cut” when armed 2 = On: if siren sounds for “Telephone Line Cut” when disarmed 3 = On: if siren blast at arming (pulse) 4 = On: if siren blast at exit expiration (pulse) 5 = On: if siren blast at closing kiss-off (pulse) 6 = On: if siren sounds during a “Cross Zone” verification time 7 = On: if siren sounds for a zone or box tamper 8 = On: if siren blasts 1 time for keyswitch or wireless arming; 2 times for disarming Segment 2 1 = On: if siren driver should be a voltage output. Off: if on-board siren driver is enabled 2 = On: if sirens sound for expander trouble 3 = On: for zones to restore immediately. Off: for zones to restore only when the siren is off or disarmed 4 = On: if dynamic battery test is performed at arming. Off: if dynamic battery test is performed at disarming (See location 40) 5 = On: if battery missing test is performed every 12 seconds 6 = On: if manual bell test is performed during [*]-[4]-[4] test function 7 = On: if manual communicator test is performed during [*]-[4]-[4] test function 8 = On: if Box Tamper terminals on the control panel are enabled Segment 3 1 = On: if box tamper report is enabled 2 = On: if AC fail reporting is enabled 3 = On: if low battery reporting is enabled 4 = On: if Aux. power overcurrent report is enabled 5 = On: if siren supervision report is enabled 6 = On: if restore telephone line cut report is enabled 7 = Reserved 8 = On: if expander trouble reporting is enabled Segment 4 1 = On: if fail to communicate report is enabled 2 = On: if log full report is enabled 3 = On: if autotest report is enabled 4 = On: if start/end programming report is enabled 5 = On: if end download report is enabled 6 = On: if sensor low battery report is enabled 7 = On: if sensor missing report is enabled 8 = On: if autotest report is enabled ONLY when the system is armed NX-8E Installation manual Page 50 Date 08/09/04