GE Security g THE NUMBER IN PARENTHESES FOLLOWING THE EVENT IS THE NUMBER THAT WILL BE REPORTED AS THE ZONE NUMBER. IF THERE ARE NO PARENTHESES, THE ZONE WILL BE “0”. SEE APPENDIX 3 FOR THE DEVICE NUMBERS. * The character transmitted in this slot will be the first character from the event code of the zone that is bypassed or in trouble (see locations 110 - 169). NX-8E Installation manual Page 121 Date 08/09/04
GE Security g APPENDIX 2: REPORTING ZONE CODES IN SIA OR CONTACT ID The NX-8E has the ability to report SIA level 1 transmissions to either or both phone numbers. Each report in SIA consists of an Event Code and a Zone or User ID. The Zone ID will be the zone number that is in alarm. The event code will come from the chart below, and it will be programmed in the configuration group event code. Programmed Event Code SIA Code Description 0 HA Holdup Alarm 1 FA Fire Alarm 2 PA Panic alarm 3 BA Burglary Alarm 4 BA Burglary Alarm 5 BA Burglary Alarm 6 UA Untyped Alarm 7 BA Burglary Alarm 8 BA Burglary Alarm 9 UA Untyped Alarm 10 HA Holdup Alarm 11 MA Medical Alarm 12 PA Panic alarm 13 TA Tamper Alarm 14 RP Periodic Test 15 GA Gas Alarm 16 KA Heat Alarm 17 WA Water Alarm 18 QA Emergency Alarm 19 SA Sprinkler Alarm 20 ZA Freeze Alarm NX-8E Installation manual Page 122 Date 08/09/04
GE Security g The NX-8E can report Ademco Contact ID transmissions. Each report in Contact ID consists of an Event Code and a Zone ID. The zone ID is the zone that generated the alarm. The event code will come from the chart below, and it will be programmed in the configuration group event code. Programmed Event Code CONTACT-ID Description 0 122 Silent Panic 1 110 Fire Alarm 2 120 Panic alarm 3 130 Burglary Alarm 4 131 Perimeter Alarm 5 132 Interior Alarm 6 133 24 Hour Burglary 7 134 Entry Alarm 8 135 Day/Night Alarm 9 150 Non Burglary 24 Hour 10 121 Duress Alarm 11 100 Medical Alarm 12 123 Audible Panic Alarm 13 137 Tamper Alarm 14 602 Periodic Test 15 151 Gas Detected 16 158 High Temp 17 154 Water Leakage 18 140 General Alarm 19 140 General Alarm 20 159 Low Temp 21 158 High Temp Alarm 22 115 Manual Fire Alarm NX-8E Installation manual Page 123 Date 08/09/04
GE Security g APPENDIX 3: EXPANDER NUMBERS FOR REPORTING EXPANDER TROUBLE The tables below list the device numbers that will be reported for each expander/keypad where a trouble condition is present. For trouble conditions relating to the control panel, the device number is “0”. Keypads KEYPAD PART 1 PART 2 PART 3 PART 4 PART 5 PART 6 PART 7 PART 8 1 192 193 194 195 196 197 198 199 2 200 201 202 203 204 205 206 207 3 208 209 210 211 212 213 214 215 4 216 217 218 219 220 221 222 223 5 224 225 226 227 228 229 230 231 6 232 233 234 235 236 237 238 239 7 240 241 242 243 244 245 246 247 8 248 249 250 251 252 253 254 255 Remote power supply NX-320E Power supply DIP 1 DIP 2 DIP 3 Expander number reported 1 OFF OFF OFF 84 2 ON 85 OFF OFF 3 OFF ON OFF 86 4 ON ON OFF 87 5 OFF OFF ON 88 6 ON OFF ON 89 7 OFF ON ON 90 8 ON ON ON 91 Wireless receiver NX-448E Wireless receiver DIP 1 DIP 2 DIP 3 Expander number reported 1 OFF 35 OFF OFF 2 ON OFF OFF 36 3 OFF ON OFF 37 4 ON ON OFF 38 5 OFF OFF ON 39 6 ON OFF ON 32 7 OFF ON ON 33 8 ON ON ON 34 NX-8E Installation manual Page 124 Date 08/09/04
GE Security g Output module NX-507E or NX-508E Output module DIP 1 DIP 2 DIP 3 Expander number reported 1 ON ON OFF 24 2 OFF OFF ON 25 3 ON OFF ON 26 4 OFF ON ON 27 5 ON ON ON 28 6 OFF OFF OFF 29 7 ON OFF OFF 30 8 OFF ON OFF 31 Hardwired expander NX-216E Starting zone number DIP 1 DIP 2 DIP 3 DIP 4 DIP 5 DIP 6 Expander number reported Zone 9 ON OFF OFF OFF OFF N/A 23 Zone 17 OFF ON OFF OFF OFF N/A 16 Zone 25 ON ON OFF OFF OFF N/A 17 Zone 33 OFF OFF ON OFF OFF N/A 18 Zone 41 ON OFF ON OFF OFF N/A 19 Zone 49 ON 20 OFF ON OFF OFF N/A Zone 57 ON ON ON OFF OFF N/A 21 Zone 65 OFF OFF OFF ON OFF N/A 96 Zone 73 ON OFF OFF 97 ON OFF N/A Zone 81 OFF ON OFF OFF ON N/A 98 Zone 89 ON ON OFF ON OFF N/A 99 Zone 97 OFF OFF ON ON OFF N/A 100 Zone 105 ON OFF N/A ON ON OFF 101 Zone 113 ON OFF ON ON OFF N/A 102 Zone 121 ON ON ON ON OFF N/A 103 Zone 129 OFF OFF OFF OFF ON N/A 104 Zone 137 ON ON OFF OFF OFF N/A 105 Zone 145 OFF ON OFF OFF ON N/A 106 Zone 153 ON ON OFF OFF ON N/A 107 Zone 161 OFF ON OFF ON OFF N/A 108 Zone 169 ON OFF ON OFF ON N/A 109 Zone 177 OFF ON ON OFF ON N/A 110 Zone 185 ON ON N/A ON OFF ON 111 NX-8E Installation manual Page 125 Date 08/09/04
GE Security g Security g CE DECLARATION NX-8E Installation manual Page 126 Date 08/09/04
GE Security g NX-8E Installation manual Page 127 Date 08/09/04
GE Security g NX-8E Installation manual Page 128 Date 08/09/04
NX-8E Installation manual Page 129 Date 08/09/04 GE Security g
www.gesecurity.com EMEA Distribution is a division of GE Security EMEA bvba COPYRIGHT ©2004 © GE Security EMEA bvba. All rights reserved. GE Security EMEA bvba grants the right to reprint this manual for internal use only. GE Security EMEA bvba reserves the right to change information without notice.