GE Security g LOCATION 166 - CONFIGURATION GROUP 29 ALARM EVENT CODE (1 segment, numerical data) Location 166 contains the event code that is sent for a Contact ID or SIA report. The desired event code should be chosen from the list on pages 121-122. The zone ID will be the zone that is in alarm. This location is not used for slow speed formats (like 4+2 and 3+1). This location may also contain the alarm report code for the Robofon format (value 00-99). LOCATION 167 - CONFIGURATION GROUP 29 CHARACTERISTIC SELECT (5 segments, feature selection data) Use the “Configuration Group Characteristic Selections” described in Location 111. LOCATION 168 - CONFIGURATION GROUP 30 ALARM EVENT CODE (1 segment, numerical data) Location 168 contains the event code that is sent for a Contact ID or SIA report. The desired event code should be chosen from the list on pages 121-122. The zone ID will be the zone that is in alarm. This location is not used for slow speed formats (like 4+2 and 3+1). This location may also contain the alarm report code for the Robofon format (value 00-99). LOCATION 169 - CONFIGURATION GROUP 30 CHARACTERISTIC SELECT (5 segments, feature selection data) Use the “Configuration Group Characteristic Selections” described in Location 111. ) LOCATION 170 - ZONES 49-56 CONFIGURATION GROUP (8 segments, numerical data) Location 170 contains the configuration group (zone type) for zones 1-8. Segment 1 is for zone 49, and segment 8 is for zone 56. You will find the default configurations in the table above. LOCATION 171 - PARTITION SELECT, ZONES 49-56 segments, feature selection data) Location 171 is used to select the partition(s) in which zones 49-56 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 49, and segment 8 corresponds to zone 56. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 NX-8E Installation manual Page 81 Date 08/09/04
![](/img/blank.gif)
GE Security g ) LOCATION 172 - ZONES 57-64 CONFIGURATION GROUP (8 segments, numerical data) Location 172 contains the configuration group (zone type) for zones 57-64. Segment 1 is for zone 57, and segment 8 is for zone 64. You will find the default configurations in the table above. LOCATION 173 - PARTITION SELECT, ZONES 57-64 (8 segments, feature selection data) Location 173 is used to select the partition(s) in which zones 57-64 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 57, and segment 8 corresponds to zone 64. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 ) LOCATION 174 - ZONES 65-72 CONFIGURATION GROUP (8 segments, numerical data) Location 174 contains the configuration group (zone type) for zones 65-72. Segment 1 is for zone 65, and segment 8 is for zone 72. You will find the default configurations in the table above. LOCATION 175 - PARTITION SELECT, ZONES 65-72 (8 segments, feature selection data) Location 175 is used to select the partition(s) in which zones 65-72 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 65, and segment 8 corresponds to zone 72. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 NX-8E Installation manual Page 82 Date 08/09/04
![](/img/blank.gif)
GE Security g ) LOCATION 176 - ZONES 73-80 CONFIGURATION GROUP (8 segments, numerical data) Location 176 contains the configuration group (zone type) for zones 73-80. Segment 1 is for zone 73, and segment 8 is for zone 80. You will find the default configurations in the table above. LOCATION 177 - PARTITION SELECT, ZONES 73-80 (8 segments, feature selection data) Location 177 is used to select the partition(s) in which zones 73-80 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 73, and segment 8 corresponds to zone 80. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 ) LOCATION 178 - ZONES 81-88 CONFIGURATION GROUP (8 segments, numerical data) Location 178 contains the configuration group (zone type) for zones 81-88. Segment 1 is for zone 81, and segment 8 is for zone 88. You will find the default configurations in the table above. LOCATION 179 - PARTITION SELECT, ZONES 81-88 (8 segments, feature selection data) Location 179 is used to select the partition(s) in which zones 81-88 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 81, and segment 8 corresponds to zone 88. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 NX-8E Installation manual Page 83 Date 08/09/04
![](/img/blank.gif)
GE Security g ) LOCATION 180 - ZONES 89-96 CONFIGURATION GROUP (8 segments, numerical data) Location 180 contains the configuration group (zone type) for zones 89-96. Segment 1 is for zone 89, and segment 8 is for zone 96. You will find the default configurations in the table above. LOCATION 181 - PARTITION SELECT, ZONES 89-96 (8 segments, feature selection data) Location 181 is used to select the partition(s) in which zones 89-96 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 89, and segment 8 corresponds to zone 96. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 ) LOCATION 182 - ZONES 97-104 CONFIGURATION GROUP (8 segments, numerical data) Location 182 contains the configuration group (zone type) for zones 97-104. Segment 1 is for zone 97, and segment 8 is for zone 104. You will find the default configurations in the table above. LOCATION 183 - PARTITION SELECT, ZONES 97-104 (8 segments, feature selection data) Location 183 is used to select the partition(s) in which zones 97-104 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 97, and segment 8 corresponds to zone 104. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 NX-8E Installation manual Page 84 Date 08/09/04
![](/img/blank.gif)
GE Security g ) LOCATION 184 - ZONES 105-112 CONFIGURATION GROUP (8 segments, numerical data) Location 184 contains the configuration group (zone type) for zones 105-112. Segment 1 is for zone 105, and segment 8 is for zone 112. You will find the default configurations in the table above. LOCATION 185 - PARTITION SELECT, ZONES 105-112 (8 segments, feature selection data) Location 185 is used to select the partition(s) in which zones 105-112 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 105, and segment 8 corresponds to zone 112. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 ) LOCATION 186 - ZONES 113-120 CONFIGURATION GROUP (8 segments, numerical data) Location 186 contains the configuration group (zone type) for zones 113-120. Segment 1 is for zone 113, and segment 8 is for zone 120. You will find the default configurations in the table above. LOCATION 187 - PARTITION SELECT, ZONES 113-120 (8 segments, feature selection data) Location 187 is used to select the partition(s) in which zones 113-120 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 113, and segment 8 corresponds to zone 120. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 NX-8E Installation manual Page 85 Date 08/09/04
![](/img/blank.gif)
GE Security g ) LOCATION 188 - ZONES 121-128 CONFIGURATION GROUP (8 segments, numerical data) Location 188 contains the configuration group (zone type) for zones 121-128. Segment 1 is for zone 121, and segment 8 is for zone 128. You will find the default configurations in the table above. LOCATION 189 - PARTITION SELECT, ZONES 121-128 (8 segments, feature selection data) Location 189 is used to select the partition(s) in which zones 121-128 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 121, and segment 8 corresponds to zone 128. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 ) LOCATION 190 - ZONES 129-136 CONFIGURATION GROUP (8 segments, numerical data) Location 190 contains the configuration group (zone type) for zones 129-136. Segment 1 is for zone 129, and segment 8 is for zone 136. You will find the default configurations in the table above. LOCATION 191 - PARTITION SELECT, ZONES 129-136 (8 segments, feature selection data) Location 191 is used to select the partition(s) in which zones 129-136 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 129, and segment 8 corresponds to zone 136. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 NX-8E Installation manual Page 86 Date 08/09/04
![](/img/blank.gif)
GE Security g ) LOCATION 192 - ZONES 137-144 CONFIGURATION GROUP (8 segments, numerical data) Location 192 contains the configuration group (zone type) for zones 137-144. Segment 1 is for zone 137, and segment 8 is for zone 144. You will find the default configurations in the table above. LOCATION 193 - PARTITION SELECT, ZONES 137-144 (8 segments, feature selection data) Location 193 is used to select the partition(s) in which zones 137-144 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 137, and segment 8 corresponds to zone 144. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 ) LOCATION 194 - ZONES 145-152 CONFIGURATION GROUP (8 segments, numerical data) Location 194 contains the configuration group (zone type) for zones 145-152. Segment 1 is for zone 145, and segment 8 is for zone 152. You will find the default configurations in the table above. LOCATION 195 - PARTITION SELECT, ZONES 145-152 (8 segments, feature selection data) Location 195 is used to select the partition(s) in which zones 145-152 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 145, and segment 8 corresponds to zone 152. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 NX-8E Installation manual Page 87 Date 08/09/04
![](/img/blank.gif)
GE Security g ) LOCATION 196 - ZONES 153-160 CONFIGURATION GROUP (8 segments, numerical data) Location 196 contains the configuration group (zone type) for zones 153-160. Segment 1 is for zone 153, and segment 8 is for zone 160. You will find the default configurations in the table above. LOCATION 197 - PARTITION SELECT, ZONES 153-160 (8 segments, feature selection data) Location 197 is used to select the partition(s) in which zones 153-160 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 153, and segment 8 corresponds to zone 160. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 ) LOCATION 198 - ZONES 161-168 CONFIGURATION GROUP (8 segments, numerical data) Location 198 contains the configuration group (zone type) for zones 161-168. Segment 1 is for zone 161, and segment 8 is for zone 168. You will find the default configurations in the table above. LOCATION 199 - PARTITION SELECT, ZONES 161-168 (8 segments, feature selection data) Location 199 is used to select the partition(s) in which zones 161-168 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 161, and segment 8 corresponds to zone 168. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 NX-8E Installation manual Page 88 Date 08/09/04
![](/img/blank.gif)
GE Security g ) LOCATION 200 - ZONES 169-176 CONFIGURATION GROUP (8 segments, numerical data) Location 200 contains the configuration group (zone type) for zones 169-172. Segment 1 is for zone 169, and segment 8 is for zone 176. You will find the default configurations in the table above. LOCATION 201 - PARTITION SELECT, ZONES 169-176 (8 segments, feature selection data) Location 201 is used to select the partition(s) in which zones 169-176 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 169, and segment 8 corresponds to zone 176. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 ) LOCATION 202 - ZONES 177-184 CONFIGURATION GROUP (8 segments, numerical data) Location 202 contains the configuration group (zone type) for zones 177-184. Segment 1 is for zone 177, and segment 8 is for zone 184. You will find the default configurations in the table above. LOCATION 203 - PARTITION SELECT, ZONES 177-184 (8 segments, feature selection data) Location 203 is used to select the partition(s) in which zones 177-184 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 177, and segment 8 corresponds to zone 184. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 NX-8E Installation manual Page 89 Date 08/09/04
![](/img/blank.gif)
GE Security g ) LOCATION 204 - ZONES 185-192 CONFIGURATION GROUP (8 segments, numerical data) Location 204 contains the configuration group (zone type) for zones 185-192. Segment 1 is for zone 185, and segment 8 is for zone 192. You will find the default configurations in the table above. LOCATION 205 - PARTITION SELECT, ZONES 185-192 (8 segments, feature selection data) Location 205 is used to select the partition(s) in which zones 185-192 reside. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, that zone will only be active when all the partitions in which it is resident in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 185, and segment 8 corresponds to zone 192. Segment 1-8 1 = Partition 1 2 = Partition 2 3 = Partition 3 4 = Partition 4 5 = Partition 5 6 = Partition 6 7 = Partition 7 8 = Partition 8 LOCATION 206 – AUTO DISARM DAY SELECTOR (8 segments, feature selection data) Location 206 selects which days each partition will auto disarm. Segment 1 is for partition 1 and segment 8 is for partition 8. Segment 1-8 1 = Auto disarming on Sunday 2 = Auto disarming on Monday 3 = Auto disarming on Tuesday 4 = Auto disarming on Wednesday 5 = Auto disarming on Thursday 6 = Auto disarming on Friday 7 = Auto disarming on Saturday 8 = Reserved LOCATION 207 – SERIAL PORT SELECTOR (1 segment, feature selection data) Location 207 enables the serial port operations. There is on segment. 0 = Disabled 1 = NX-584 enabled 2 = Serial printer enabled NX-8E Installation manual Page 90 Date 08/09/04