GE Nx 8 Manual
Here you can view all the pages of manual GE Nx 8 Manual. The GE manuals for Control panel are available online for free. You can easily download all the documents as PDF.
Page 111
GE Security g 180 84 ZONES 89-96, CONFIGURATION GROUPS 6-6-6-6-6-6-6-6 ZONES 89-96, PARTITION SELECTION (Segment 1=Zone 89 thru Segment 8=Zone 96) Segments 1 2 3 4 5 6 7 8 Partition 1 1 1 1 1 1 1 1 1 Partition 2 2 2 2 2 2 2 2 2 Partition 3 3 3 3 3 3 3 3 3 Partition 4 4 4 4 4 4 4 4 4 Partition 5 5 5 5 5 5 5 5 5 Partition 6 6 6 6 6 6 6 6 6 Partition 7 7 7 7 7 7 7 7 7 181 84 Partition 8 8 8 8 8 8 8 8 8 182 84 ZONES 97-104, CONFIGURATION GROUPS 6-6-6-6-6-6-6-6 ZONES 97-104,...
Page 112
GE Security g 190 86 ZONES 129-136, CONFIGURATION GROUPS 6-6-6-6-6-6-6-6 ZONES 129-136, PARTITION SELECTION (Segment 1=Zone 129 thru Segment 8=Zone 136) Segments 1 2 3 4 5 6 7 8 Partition 1 1 1 1 1 1 1 1 1 Partition 2 2 2 2 2 2 2 2 2 Partition 3 3 3 3 3 3 3 3 3 Partition 4 4 4 4 4 4 4 4 4 Partition 5 5 5 5 5 5 5 5 5 Partition 6 6 6 6 6 6 6 6 6 Partition 7 7 7 7 7 7 7 7 7 191 86 Partition 8 8 8 8 8 8 8 8 8 192 87 ZONES 137-144, CONFIGURATION GROUPS 6-6-6-6-6-6-6-6 ZONES...
Page 113
GE Security g 200 89 ZONES 169-176, CONFIGURATION GROUPS 6-6-6-6-6-6-6-6 ZONES 169-176, PARTITION SELECTION (Segment 1=Zone 169 thru Segment 8=Zone 176) Segments 1 2 3 4 5 6 7 8 Partition 1 1 1 1 1 1 1 1 1 Partition 2 2 2 2 2 2 2 2 2 Partition 3 3 3 3 3 3 3 3 3 Partition 4 4 4 4 4 4 4 4 4 Partition 5 5 5 5 5 5 5 5 5 Partition 6 6 6 6 6 6 6 6 6 Partition 7 7 7 7 7 7 7 7 7 201 89 Partition 8 8 8 8 8 8 8 8 8 202 89 ZONES 177-184, CONFIGURATION GROUPS 6-6-6-6-6-6-6-6 ZONES...
Page 114
GE Security g SERIAL PORT ENABLE 0 0 = disabled 1 = Home automation protocol enabled 207 90 2 = Serial printer interface SERIAL PORT BAUD RATE 2 0 = 2400 (2.4K) 3 = 19200 (19.2K) 1 = 4800 (4.8K) 4 = 38400 (38.4K) 208 91 2 = 9600 (9.6K) 5-7 = Reserved HOME AUTOMATION PROTOCOL Off OFF = Binary 209 91 ON = ASCII NX-8E TRANSITION-BASED BROADCASTS Segment 1 (Circle Numbers To Program) Segment 2 (Circle Numbers To Program) 1 Reserved 1 System status message 2...
Page 115
GE Security g Security g BOARD INSTALLATION Inside the can, several 2-holed insertion points have been constructed. This allows for either Diagram 1: vertical or horizontal placement of the modules. Notice that each insertion point has two sizes of holes -a larger hole and a smaller hole. The black plastic PCB guides are grooved on one edge where the PC board will be seated. The end with the half-moon protrusion fits into the larger hole. The smaller hole is for the...
Page 117
GE Security g TERMINAL DESCRIPTION TERMINAL DESCRIPTION R1 House Telephone Ring. R Telephone Ring. T Telephone Tip. T1 House Telephone Tip. EARTH Earth Ground. AC AC input. Connect to a 16.5Vac 40VA CE approved transformer. BELL + & BELL - If used as a siren output (default), the speaker rating should be 15 watt at 8 or 16 ohm, or 30/40 watt at 4, 8, or 16 ohms. If voltage output is selected in location 37, this output becomes voltage output, 12VDC, 1 Amp maximum load....
Page 118
GE Security g TECHNICAL SPECIFICATIONS Technical specifications NX-8E Operating power - Nominal 16.5Vac, 50/60Hz, 40VA Current consumption 60mA Battery 285 g max. 12V/18 Ah Auxiliary Power Supply EN50131-6 Grade 2 Type A - Minimum 11.00 Vdc - Nominal 13.85 Vdc - Maximum 14.00 Vdc Max. ripple < 5% Operating temperature 0 - 50° C Loop resistance - Standard loop 300 Ohms maximum - 2-wire fire loop 30 Ohms maximum Built-in siren driver 112 dB, 2 tones (steady or yelp)...
Page 119
GE Security g Technical specifications NX-1308, NX-1316, NX-1324 Operating power - Nominal 12 Vdc - Minimum/maximum 9 Vdc - 14 Vdc Operating temperature 0 - 50° C Dimensions Current consumption 29 mA 90 mA 9 Vdc - 14 Vdc 158 x 135 x 30 mm 158 x 135x 30 mm NX-1308 NX-1316 NX-1324 - Minimum (quiescent, no lighting) 23 mA 23 mA 23 mA - Nominal (quiescent, lighting ON) 29 mA 29 mA Current consumption in alarm - 1 zone in alarm, sounder/lighting ON 55...
Page 120
GE Security g APPENDIX 1: REPORTING FIXED CODES IN CONTACT-ID AND SIA The table below lists the event codes sent for the following reports (if enabled) when using CONTACT ID or SIA formats. REPORT CONTACT ID SIA MANUAL TEST 601 RX AUTOTEST 602 RP OPEN (User Number) 401 OP CLOSE (User Number) 401 CL CANCEL (User Number) 406 OC DOWNLOAD COMPLETE 412 RS START PROGRAM 627 LB END PROGRAM 628 LX RECENT CLOSE (User Number) 401 CR EXIT ERROR (User Number) 457 EE EVENT LOG FULL...