Page 61

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 61
Bosch Security Systems | 1/04 | 47775E
To Walk Test a Door point connected to a
D9210B Access Interface Module, the
door must be opened without activating
the door sequence or allowing it to time
out past the extended shunt time.
L## Fire Test
Default:See Program Record Sheet
Selection:Blank or E
#12 Fire Test [COMMAND][5][8]
Initiate a Fire Walk Test for all 24-hour points in the
area where this command center is assigned.
When a Fire Test is...

Page 62

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 62
Bosch Security Systems | 1/04 | 47775E
L## Unlock Door
Default:See Program Record Sheet
Selection:Blank or E
Unlock Door (MENU FUNCTION only)
Press the command center number keys [1] through
[8] that correspond to the door number to
unlock/relock doors. For example, pressing [2] and
[ENTER] unlocks door number 2, which is indicated
by U in the display.
Unlock Door allows the user with this authority level
to access the UNLOCK? 12345678 function....

Page 63

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 63
Bosch Security Systems | 1/04 | 47775E
L## Chg Display
Default:See Program Record Sheet
Selection:Blank or E
#15 Change Display [COMMAND][4][9]
Change the display (bright display, dim display, and
time display) in the area where this command center
is assigned.
L## Chg Time/Date
Default:See Program Record Sheet
Selection:Blank or E
#16 Change Time and Date [COMMAND][4][5]
Change the date and time for the control panel in
this area.
L## Chg...

Page 64

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 64
Bosch Security Systems | 1/04 | 47775E
L## User Cmd 9
Default:See Program Record Sheet
Selection:Blank or E
#24 User COMMAND 9 [COMMAND][9]
Can be used in Function Menu. Generate the alarm
programmed at COMMAND 9 in the RADXPNTS
Handler.
L## Bypass a Pt
Default:See Program Record Sheet
Selection:Blank or E
#25 Bypass a Point [COMMAND][0]
Bypass points with this authority level
L## Unbypass a Pt
Default:See Program Record Sheet
Selection:Blank or...

Page 65

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 65
Bosch Security Systems | 1/04 | 47775E
- D1255 command center displays a
sequential count after each point is activated
and restored as well as the text for the point.
- The D1255 command center displays ALL
PNTS TESTED.
- If enabled in Routing, Service Start and
Service End are reported at the central
station receiver for the beginning and end of
the test.
Point 128 and Point 248 appear as missing. This is
normal. These points are used for...

Page 66

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 66
Bosch Security Systems | 1/04 | 47775E
L## Passcode Disarm
Default:See Program Record Sheet
Selection:Blank or E
Disarm an area by entering a passcode and pressing
[ENTER].
Access Control Levels
L## Security Level
Default:See Program Record Sheet
Selection:M, P, D, or Blank
M Users have access rights for this area
when the area is in any armed state.
P Users have access rights for this area
when the area is Perimeter Armed or
disarmed but not...

Page 67

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 67
Bosch Security Systems | 1/04 | 47775E
2.12 Function List
The Function List is accessed when the user presses
[MENU] (or the key corresponding to menu) on the
D1260) while the command center is displaying the
idle text. Up to 32 functions M### Function(s) can
be programmed.
Each CC # command center address can display a
combination of all/each of the 32 menu items. The
D1255 displays one menu item at a time. The D1260
displays up to two menu items...

Page 68

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 68
Bosch Security Systems | 1/04 | 47775E
• Relay Reports: When relay activity is reported
to the receiver (see Section 2.3 Routing), on-board
relays are reported as follows: A = 253, B = 254,
C = 255. The others report as 001 to 128. The
Relay Report is RELAY SET RELAY # rrr
when the relay is turned on and RELAY RESET
RELAY # rrr when the relay is turned off. Relay
Reports are also printed on the local printer and
stored in the control panel memory...

Page 69

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 69
Bosch Security Systems | 1/04 | 47775E
A# Fire Bell
Default:A
Selection:Blank, 1 to 128 (1 to 64 for D7412G),
A, B, or C
This voltage output relay activates and provides
12 VDC output when a Fire point (
P## Fire is Yes)
assigned to this area goes into alarm.
0101
0101
0101Fire Time and Fire Pat must be
programmed in Bell Parameters. This relay
activates according to the bell pattern and
remains active until the bell time expires.
P## Silent Bell...

Page 70

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 70
Bosch Security Systems | 1/04 | 47775E
A# Area Armed
Default:Blank
Selection:Blank, 1 to 128 (1 to 64 for D7412G),
A, B, or C
Activates when the specified area becomes master
armed (exit delay must expire before the relay
activates). The relay remains activated until the area
is disarmed. It does not deactivate during the entry
delay time.
If multiple areas use the same relay, the relay
activates when all areas are armed. It deactivates
when the...