Home > Bosch > Home Security System > Bosch 7412 G User Manual

Bosch 7412 G User Manual

Here you can view all the pages of manual Bosch 7412 G User Manual. The Bosch manuals for Home Security System are available online for free. You can easily download all the documents as PDF.

Page 31

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 31
Bosch Security Systems | 1/04 | 47775E
P## Auto Functions Event
Default:See Program Record Sheet
Selection:Yes or No
P## RAM Event
Default:See Program Record Sheet
Selection:Yes or No
P## Relay Event
Default:See Program Record Sheet
Selection:Yes or No
P## Point Event
Default:See Program Record Sheet
Selection:Yes or No
P## Usr Chng Evt
Default:See Program Record Sheet
Selection:Yes or No
2.7 RAM Parameters
Use these program items to enable Remote...

Page 32

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 32
Bosch Security Systems | 1/04 | 47775E
RAM Passcode
Default:999999
Selection:0 to 9, A to F
(six characters required)
Enter six characters. Do not use a space in the
passcode.
The control panel verifies the Remote Account
Manager at the central station has valid access
before connecting using the RAM passcode.
Log % Full
Default:Blank
Selection:1 to 99, or Blank
This parameter determines how full the memory log
should be before initiating a call...

Page 33

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 33
Bosch Security Systems | 1/04 | 47775E
0101
0101
0101Program this item No if it causes false
seizures of the phone line or if you are not
using RAM (this indicates a device using
the same frequency tone is also using the
phone line to which the control panel is
connected).
If RAM Call Back is programmed Yes, the
control panel hangs up the phone after
the RAM tone and a proper RAM
passcode is identified. It then calls the
RAM phone number.
Answer...

Page 34

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 34
Bosch Security Systems | 1/04 | 47775E
2.8 Miscellaneous
Duress Type
Default:1
Selection:1 or 2
1 Add 1 to the last digit to generate an alarm. For
example, if the passcode is 6123, 6124 triggers a
duress alarm.
If the last digit of the passcode is 0, a duress
alarm is generated when the user enters 1 as the
last digit of the passcode.
If the last digit of the passcode is 9, a duress
alarm is generated when the user enters 0 as the
last digit of...

Page 35

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 35
Bosch Security Systems | 1/04 | 47775E
A# Acct Number
Default:0000
Selection:For BFSK: 0000 to  0999,
0BBB to 0FFF
For Modem (four-digit account
numbers): 0000 to 9999,
BBBB to FFFF
For Modem (ten-digit account
numbers): 0000000000 to
9999999999, BBBBBBBBBB to
FFFFFFFFFF
Determines the account number reported for this
area. An account number must be assigned to each
active area.
Account numbers are used to group areas together.
Each area can have...

Page 36

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 36
Bosch Security Systems | 1/04 | 47775E
Figure 2: Account Number Entry
2233445511
234567
1
1 - RPS account number entry
2 - Corresponding D5200 account number digits
3 - Digits 1 and 2
4 - Digits 3 and 4
5 - Digits 5 and 6
6 - Digits 7 and 8
7 - Digits 9 and 10
Although the D5200 allows the character
“A” to be entered into the account, do
NOT use this character for the account
number.
Make sure your central station receivers
(D6500 MPU version 1.06...

Page 37

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 37
Bosch Security Systems | 1/04 | 47775E
A# Auto Watch
Default:No
Selection:Yes or No
Yes When the area is disarmed, Watch
Mode turns on automatically.
No When the area is disarmed, Watch
Mode must be turned on or off
manually.
0101
0101
0101Controlled points must be programmed
as P## Watch Point to generate a watch
tone.
A# Verify Time
Default:60
Selection:10 to 60 (in 1-second increments)
Alarm verification is designed for use with smoke
detectors...

Page 38

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 38
Bosch Security Systems | 1/04 | 47775E
A# Duress Enable
Default:No
Selection:Yes or No
Yes Enable Duress alarm for this area.
No Disable Duress alarm for this area.
This entry determines if this area allows duress
alarms to be generated. See the 
Duress Type
prompt 
 in Section 2.8 Miscellaneous for an
explanation of duress.
Setting this item to No for a particular area
and entering a valid duress passcode for
that area at the command center now...

Page 39

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 39
Bosch Security Systems | 1/04 | 47775E
A# Area Type
Default:Regular
Selection:Regular, Master, Associate, or Shared
Regular Arms or disarms as an independent area.
Master Does not allow arming for this area unless all associate areas with the same A# account number are
master exit delay arming or master armed. CHK AREA displays if the associate areas are not armed.
Exception: RPS allows master areas to be armed without all associate areas being in...

Page 40

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 40
Bosch Security Systems | 1/04 | 47775E
2.9.3 Shared-Area Characteristics
Arming a Shared Area
Requires all associate areas to be armed. As soon as
the last associate area is armed, the shared area
begins its arming sequence automatically. Passcode,
keyswitch, sub-controls, or RAM cannot arm shared
areas. To display faulted points at associated areas,
the shared and associate areas must have the same
account number.
Disarming a Shared Area
Shared...