Page 41
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 41 Bosch Security Systems | 1/04 | 47775E A# Fire Time Default:9 Selection:1 minute to 90 minutes Enter the number of minutes the bell rings for Fire Alarm points. The relay activated for this time is programmed in A# Fire Bell in Area Relays. The bell output begins as soon as the fire alarm occurs. It shuts off the bell when the programmed number of minutes expires. If programmed for 1 minute, the output may be anywhere from 0 to 60 seconds of bell...
Page 42
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 42 Bosch Security Systems | 1/04 | 47775E If a 24-hour point alarms while the area is disarmed, arming that area with a keyswitch does not clear the A# Single Ring flag. Silencing the bell resets A# Single Ring. A# Bell Test Default:No Selection:Yes or No Yes Initiate Bell Test. No Do not initiate Bell Test. Provide alarm output from the relay programmed at A# Alarm Bell after the Closing Report was confirmed or the exit delay time expired. Bell Test...
Page 43
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 43 Bosch Security Systems | 1/04 | 47775E Combination Account and Area Opening and Closing Reports To send both account openings and closings, and individual area openings and closings for all areas in the account, you must: • Program A# Acct O/C Yes for all areas in the account. • Program A# Area O/C Yes for all areas in the account. Closing Reports: When areas in the account are independently armed, each area generates an Area Closing Report....
Page 44
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 44 Bosch Security Systems | 1/04 | 47775E A# Area O/C Default:Yes Selection:Yes or No Yes Include the Area # and generate Opening and Closing Reports for this area when it is armed. No Do not include the Area # or generate Opening and Closing Reports for this area. Determines if the area number and the account number are reported upon arming and disarming. As long as Account O/C is No, the account number reports when arming this area individually....
Page 45
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 45 Bosch Security Systems | 1/04 | 47775E A# Fail to Close Default:No Selection:Yes or No Yes Fail to Close Report occurs for this area if the area was not armed when the Closing Window stop time occurred. Note: An exit delay time must be programmed in Exit Dly Time. No Fail to Close Report is not sent for this area. Note: If Auto Close is programmed Yes, a Fail to Close Report is sent because it occurs when the Closing Window stop time occurred. If...
Page 46
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 46 Bosch Security Systems | 1/04 | 47775E A# Perimeter O/C Default:No Selection:Yes or No Yes This area can send Perimeter Opening and Closing Reports. No This area cannot send Perimeter Opening and Closing Reports. This item determines if this area can send Perimeter Instant and Perimeter Delay Closing Reports and normal Opening Reports to the central station. Opening/Closing Windows do not suppress this event. Modem format reporting is required....
Page 47
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 47 Bosch Security Systems | 1/04 | 47775E CC# Supervised Default:See Program Record Sheet Selection:Yes or No Yes Only one command center can be installed for this CC SDI address. No More than one command center can be installed using this CC SDI address with the same address DIP switch setting. Supervise this SDI address and generate Trouble SDI Reports and local trouble annunciation if a problem occurs with this command center or the SDI bus....
Page 48
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 48 Bosch Security Systems | 1/04 | 47775E CC# A1[through A8] in Scope Default:See preceding important note Selection:Yes or No Yes Include this area in the scope of this command center. No Do not include this area in the scope of this command center. Determines whether any of the eight areas (Area 1 to Area 8) and Doors (Door 1 to Door 8) are included in the scope of this command center for viewing status, arming or disarming, and controlling doors...
Page 49
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 49 Bosch Security Systems | 1/04 | 47775E CC# Assign Door Default:Blank Selection:1 to 8, Blank Blank No door controller is assigned for adding tokens or the CLOSE DOOR # displays on the command center. 1 to 8 Assign the door controller that enters the Add User Mode when initiated. This door activates the CLOSE DOOR # displays at this command center if CC Close Door is Yes. Program the door number used by this command center for adding tokens/cards...
Page 50
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 50 Bosch Security Systems | 1/04 | 47775E 0101 0101 0101This prompt allows you to manage the tone by command center. Exit Tone can also be turned off when programming A# Exit Tone in Area Parameters. Assign two CCs to the same area so one command center emits the tone and another does not. CC# Arm Now Warn Default:No Selection:Yes or No Yes This command center activates a tone and displays PLEASE CLOSE NOW. No This command center does not activate...