Page 41

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 41
Bosch Security Systems | 1/04 | 47775E
A# Fire Time
Default:9
Selection:1 minute to 90 minutes
Enter the number of minutes the bell rings for Fire
Alarm points. The relay activated for this time is
programmed in 
A# Fire Bell in Area Relays.
The bell output begins as soon as the fire alarm
occurs. It shuts off the bell when the programmed
number of minutes expires.
If programmed for 1 minute, the output may be
anywhere from 0 to 60 seconds of bell...

Page 42

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 42
Bosch Security Systems | 1/04 | 47775E
If a 24-hour point alarms while the area is
disarmed, arming that area with a
keyswitch does not clear the A# Single
Ring flag.
Silencing the bell resets A# Single Ring.
A# Bell Test
Default:No
Selection:Yes or No
Yes Initiate Bell Test.
No Do not initiate Bell Test.
Provide alarm output from the relay programmed at
A# Alarm Bell after the Closing Report was
confirmed or the exit delay time expired.
Bell Test...

Page 43

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 43
Bosch Security Systems | 1/04 | 47775E
Combination Account and Area Opening and
Closing Reports
To send both account openings and closings, and
individual area openings and closings for all areas in
the account, you must:
• Program 
A# Acct O/C  Yes for all areas in the
account.
• Program 
A# Area O/C  Yes for all areas in the
account.
Closing Reports: When areas in the account are
independently armed, each area generates an Area
Closing Report....

Page 44

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 44
Bosch Security Systems | 1/04 | 47775E
A# Area O/C
Default:Yes
Selection:Yes or No
Yes Include the Area # and generate Opening and
Closing Reports for this area when it is armed.
No Do not include the Area # or generate
Opening and Closing Reports for this area.
Determines if the area number and the account
number are reported upon arming and disarming.
As long as 
Account O/C is No, the account number
reports when arming this area individually....

Page 45

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 45
Bosch Security Systems | 1/04 | 47775E
A# Fail to Close
Default:No
Selection:Yes or No
Yes Fail to Close Report occurs for this area if the
area was not armed when the Closing
Window stop time occurred.
Note:
An exit delay time must be programmed in Exit
Dly Time.
No Fail to Close Report is not sent for this area.
Note:
If Auto Close is programmed Yes, a Fail to
Close Report is sent because it occurs when the
Closing Window stop time occurred.
If...

Page 46

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 46
Bosch Security Systems | 1/04 | 47775E
A# Perimeter O/C
Default:No
Selection:Yes or No
Yes This area can send Perimeter Opening and
Closing Reports.
No This area cannot send Perimeter Opening and
Closing Reports.
This item determines if this area can send Perimeter
Instant and Perimeter Delay Closing Reports and
normal Opening Reports to the central station.
Opening/Closing Windows do not suppress this
event.
Modem format reporting is required....

Page 47

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 47
Bosch Security Systems | 1/04 | 47775E
CC# Supervised
Default:See Program Record Sheet
Selection:Yes or No
Yes Only one command center can be installed for
this CC SDI address.
No More than one command center can be
installed using this CC SDI address with the
same address DIP switch setting.
Supervise this SDI address and generate Trouble
SDI Reports and local trouble annunciation if a
problem occurs with this command center or the
SDI bus....

Page 48

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 48
Bosch Security Systems | 1/04 | 47775E
CC# A1[through A8] in Scope
Default:See preceding important note
Selection:Yes or No
Yes Include this area in the scope of this
command center.
No Do not include this area in the scope of
this command center.
Determines whether any of the eight areas (Area 1 to
Area 8) and Doors (Door 1 to Door 8) are included
in the scope of this command center for viewing
status, arming or disarming, and controlling doors...

Page 49

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 49
Bosch Security Systems | 1/04 | 47775E
CC# Assign Door
Default:Blank
Selection:1 to 8, Blank
Blank No door controller is assigned for adding
tokens or the CLOSE DOOR # displays on
the command center.
1 to 8 Assign the door controller that enters the
Add User Mode when initiated. This door
activates the CLOSE DOOR # displays at
this command center if CC Close Door is
Yes.
Program the door number used by this command
center for adding tokens/cards...

Page 50

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 50
Bosch Security Systems | 1/04 | 47775E
0101
0101
0101This prompt allows you to manage the
tone by command center. Exit Tone can
also be turned off when programming A#
Exit Tone in Area Parameters.
Assign two CCs to the same area so one
command center emits the tone and
another does not.
CC# Arm Now Warn
Default:No
Selection:Yes or No
Yes
This command center activates a tone
and displays PLEASE CLOSE NOW.
No This command center does not activate...