Page 11
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 11 Bosch Security Systems | 1/04 | 47775E 2.0 9000MAIN Use this programming module to define the operating characteristics that affect panel-wide functions. There are nine programming categories in this module: Phone, Phone Parameters, Routing, Enhanced Communications, Area Parameters, Command Center, User Interface, Function List, and Relay Parameters. 2.1 Phone The control panel can dial up to four different telephone numbers when sending event...
Page 12
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 12 Bosch Security Systems | 1/04 | 47775E 2.2 Phone Parameters The program items in this category describe panel- wide characteristics for telephone dialing, receiver format, and supervision. Modem Format Default:Yes Selection:Yes or No Yes Radionics’ Modem IIIa2 Communication Format: Reports identify points as 001 through 247 and passcode User ID codes as 000 through 249 at the D6500/D6600 Receiver (unless Point/User Flag is programmed Yes; see the...
Page 13
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 13 Bosch Security Systems | 1/04 | 47775E Table 6: Modem IIIa2 Communication Format Data - User ID Numbers Point/User Flag NOPoint/User Flag YES 000000 001 to 005 001 to 005 006 to 013601 to 608 014 to 021 701 to 708 022 to 029801 to 808 030 to 037 B01 to B08 038 to 045C01 to C08 046 to 053 D01 to D08 054 to 061E01 to E08 062 to 069 F01 to F08 070 to 249000 Table 7: Modem IIIa2 Communication Format Data – Point Numbers Point/User Flag NOPoint/User...
Page 14
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 14 Bosch Security Systems | 1/04 | 47775E Phone Supv Time Default:Blank Selection:Blank or 10 to 240 Blank No phone line supervision. 10 to 240 Enter the number of seconds (in 10 second increments) you wish to supervise the phone line. After a faulted phone line restores, it takes the same amount of time to initiate restoral responses. Phone line trouble responses: Command centers display SERVC PH LINE # to indicate which phone line failed. The...
Page 15
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 15 Bosch Security Systems | 1/04 | 47775E BFSK Duress Code Default:0 Selection:0 to 9 If Duress Enable in Area Parameters is Yes and Modem Format in Phone Parameters is No, you must program a number to identify Duress Reports at the central station. Expand Test Rpt Default:No Selection:Yes or No Yes Report events listed in Routing Group Test Reports report to the central station if they are off-normal. No Does not report off-normal conditions for the...
Page 16
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 16 Bosch Security Systems | 1/04 | 47775E 2.3.3 Programming a Primary and Backup Destination Each route number has an R# Primary Device and an R# Backup Device. In typical applications where two phone numbers are programmed, the R# Primary Device destination is the phone number the route group attempts to dial first. If the R# Primary Device destination fails to connect to the central station receiver after two dialing attempts, the R# Backup...
Page 17
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 17 Bosch Security Systems | 1/04 | 47775E Route # Default:1 Selection:1 to 4 1 First group sent 2 Second group sent 3 Third group sent 4 Fourth group sent Enter the number specifying the route group to program. The route represents the group you wish to send a group of reports. The groups are prioritized. 1 is the first group to report and 4 is the last group to report. Each group has a primary and a backup device. The primary device is the first...
Page 18
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 18 Bosch Security Systems | 1/04 | 47775E Fire Reports Selecting Yes enables a report to be sent when the event occurs. Table 9: Diagnostic Reports Report Selections Description R# Fire AlarmYes, NoReports Fire Event. R# Fire Restore (Alarm)Yes, NoReports fire restoral from alarm. R# Fire MissingYes, NoReports missing Fire point. R# Fire Trouble Yes, NoReports fire trouble. R# Fire Supervis Yes, NoReports fire supervision. R# Fire Restore (T/M/S)Yes,...
Page 19
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 19 Bosch Security Systems | 1/04 | 47775E Restoral Reports are not sent if the control panel is reset after a point is bypassed and then the point is unbypassed. This is true for both Fire and Non-fire points. The 9000 Series Control Panels log a Ground Fault Event as Trouble Point 256. User Reports Selecting Yes enables a report to be sent when the event occurs. Table 11: User Reports Report Selections Description R# Point Bypass Yes, NoReports...
Page 20
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 20 Bosch Security Systems | 1/04 | 47775E Test Reports 0101 0101 0101To send a single Test Report (R# Test Report), enable Sked Function Code #9 (Test Report) in the Skeds section of the program. To expand this Test Report to include any off-normal point condition or other off- normal conditions of events listed in Diag Reports as a Non-status Event following a Test Report, Expand Test Rpt in Section 2.2 Phone Parameters must be programmed Yes....