Page 51
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 51 Bosch Security Systems | 1/04 | 47775E Area # Acct Is On Default:See Program Record Sheet Selection:Sixteen alphanumeric characters Enter the text that displays when all areas sharing the same account number are master armed. The ACCT IS ON text appears at all command centers assigned to these areas, if more than one area has the same account number. The ACCT IS ON text also appears if only one area in the system is used. See the prompts CC# Area...
Page 52
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 52 Bosch Security Systems | 1/04 | 47775E CF### Key Strokes Default:See Program Record Sheet Selection:Up to 32 characters: 0 to 9, A, B, C, D, and E Selection Key Faceplate Label 0 to 9 0 to 9 A [COMMAND] B [PREV] (previous) ↑ C [ESC] (escape) MENU D[NEXT] ↓ E [ENT] (enter) YES The keystrokes simulate any sequence of keystrokes the user can perform at a command center. You can program up to 32 keystrokes for each Custom Function. 0101 0101 0101D5200...
Page 53
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 53 Bosch Security Systems | 1/04 | 47775E • Custom Functions can perform several tasks at once. For example: - To toggle relays 7, 8, and 9 in one Custom Function enter: [A] [5] [4] [7] [E] [E] [8] [E] [E] [9] [E] [E] [C] - To add a temporary passcode, enter: [A] [5] [6] [3] [0] [E] [E] [9] [8] [7] [E] [E] [D] [E] [1] [E] [1] [E] [1] [E] [1] [E] [1] [E] [1] [E] [1] [E] [1] [E] [C] This adds user 30, passcode 987 with authority level 1 in all areas. -...
Page 54
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 54 Bosch Security Systems | 1/04 | 47775E Master Arm Delay Default:P Selection:Blank, E, or P P Passcode: Required for all users with Master Arm Delay enabled for their authority level. E Enable: A user does not need a passcode to use [COMMAND][1]. Blank Disable Master Arm Delay cannot be accessed in the function menu or initiated with a command even if this function is enabled for the user’s authority level. #2 Master Arm Delay [COMMAND][1] Use this...
Page 55
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 55 Bosch Security Systems | 1/04 | 47775E View Area Stat Default:P Selection:Blank, E, or P #8 View Area Status (MENU FUNCTION only) Use this function to view the armed status of all areas within the scope of the command center assigned to this area. The armed states include A# AREA # IS OFF (disarmed), A# AREA # IS ON (master delay armed), ALL ON INSTANT (master instant armed), and AREA # PERIM ON (perimeter instant armed or perimeter delay armed)....
Page 56
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 56 Bosch Security Systems | 1/04 | 47775E Access Ctl Level Default:P Selection:Blank, E, or P #37 Access Control Levels (MENU FUNCTION only) Shows the current on/off state of control levels 1 through 14, pertaining to Access Control Only, ( L## Access Level and L## Disarm Level). It allows the user to toggle levels on and off and prevent access control levels from being valid during an extended period. This change only affects the user’s token/cards,...
Page 57
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 57 Bosch Security Systems | 1/04 | 47775E Print Log Default:P Selection:Blank, E, or P #22 Print Event Log (MENU FUNCTION only) Use this function to print all the events stored in the control panel starting at the start date and ending with the last event in the log. User Cmd 7 Default:P Selection:Blank, E, or P #23 User COMMAND 7 [COMMAND][7] Use this function to activate an alarm programmed in COMMAND 7 in the RADXPNTS Handler. User Cmd 9...
Page 58
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 58 Bosch Security Systems | 1/04 | 47775E Move to Area Default:P Selection:Blank, E, or P #30 Move to Area [COMMAND][5][0] Use this function to temporarily switch the command center’s assignment to a different area. This can be used to perform any function that can be performed by a command center assigned to the area in programming. Users are limited to performing functions enabled by the authority level they have in the area to which the command...
Page 59
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 59 Bosch Security Systems | 1/04 | 47775E 2.11.3 Authority Level Selections Use Section 2.11.3 Authority Level Selections to determine which Authority Level can access command center functions that are Passcode Protected. You do not need to select Enable items in the Authority Level section if the command center function is disabled or enabled. There are two selections you can use for each individual function for the authority level you are...
Page 60
D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 60 Bosch Security Systems | 1/04 | 47775E L## Perim Instant Default:See Program Record Sheet Selection:Blank or E #4 Perimeter Instant Arm [COMMAND][2] Instant arm all Perimeter points, including Delayed points, only in the area where the command center is assigned. L## Perim Delay Default:See Program Record Sheet Selection:Blank or E #5 Perimeter Delay Arm [COMMAND][3] Delay arm all Perimeter Delay point responses only in the area where the command...