D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 51
Bosch Security Systems | 1/04 | 47775E
Area # Acct Is On
Default:See Program Record Sheet
Selection:Sixteen alphanumeric characters
Enter the text that displays when all areas sharing
the same account number are master armed. The
ACCT IS ON text appears at all command centers
assigned to these areas, if more than one area has the
same account number. The ACCT IS ON text also
appears if only one area in the system is used. See
the prompts 
CC# Area...

Page 52

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 52
Bosch Security Systems | 1/04 | 47775E
CF### Key Strokes
Default:See Program Record Sheet
Selection:Up to 32 characters: 0 to 9, A, B, C,
D, and E
Selection Key Faceplate Label
0 to 9 0 to 9
A [COMMAND]
B [PREV] (previous)
↑
C [ESC] (escape) MENU
D[NEXT]
↓
E [ENT] (enter) YES
The keystrokes simulate any sequence of keystrokes
the user can perform at a command center. You can
program up to 32 keystrokes for each Custom
Function.
0101
0101
0101D5200...

Page 53

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 53
Bosch Security Systems | 1/04 | 47775E
• Custom Functions can perform several tasks at
once. For example:
- To toggle relays 7, 8, and 9 in one Custom
Function enter:
[A] [5] [4] [7] [E] [E] [8] [E] [E] [9] [E] [E] [C]
- To add a temporary passcode, enter:
[A] [5] [6] [3] [0] [E] [E] [9] [8] [7] [E] [E] [D]
[E] [1] [E] [1] [E] [1] [E] [1] [E] [1] [E] [1] [E]
[1] [E] [1] [E] [C]
This adds user 30, passcode 987 with
authority level 1 in all areas.
-...

Page 54

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 54
Bosch Security Systems | 1/04 | 47775E
Master Arm Delay
Default:P
Selection:Blank, E, or P
P
Passcode: Required for all users with
Master Arm Delay enabled for their
authority level.
E
Enable: A user does not need a
passcode to use [COMMAND][1].
Blank Disable Master Arm Delay cannot be
accessed in the function menu or
initiated with a command even if this
function is enabled for the user’s
authority level.
#2 Master Arm Delay [COMMAND][1]
Use this...

Page 55

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 55
Bosch Security Systems | 1/04 | 47775E
View Area Stat
Default:P
Selection:Blank, E, or P
#8 View Area Status (MENU FUNCTION only)
Use this function to view the armed status of all
areas within the scope of the command center
assigned to this area. The armed states include A#
AREA # IS OFF (disarmed), A# AREA # IS ON
(master delay armed), ALL ON INSTANT (master
instant armed), and AREA # PERIM ON (perimeter
instant armed or perimeter delay armed)....

Page 56

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 56
Bosch Security Systems | 1/04 | 47775E
Access Ctl Level
Default:P
Selection:Blank, E, or P
#37 Access Control Levels (MENU FUNCTION
only)
Shows the current on/off state of control levels 1
through 14, pertaining to Access Control Only,
(
L## Access Level and L## Disarm Level). It
allows the user to toggle levels on and off and
prevent access control levels from being valid during
an extended period. This change only affects the
user’s token/cards,...

Page 57

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 57
Bosch Security Systems | 1/04 | 47775E
Print Log
Default:P
Selection:Blank, E, or P
#22 Print Event Log (MENU FUNCTION only)
Use this function to print all the events stored in the
control panel starting at the start date and ending
with the last event in the log.
User Cmd 7
Default:P
Selection:Blank, E, or P
#23 User COMMAND 7 [COMMAND][7]
Use this function to activate an alarm programmed
in COMMAND 7 in the RADXPNTS Handler.
User Cmd 9...

Page 58

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 58
Bosch Security Systems | 1/04 | 47775E
Move to Area
Default:P
Selection:Blank, E, or P
#30 Move to Area [COMMAND][5][0]
Use this function to temporarily switch the
command center’s assignment to a different area.
This can be used to perform any function that can
be performed by a command center assigned to the
area in programming.
Users are limited to performing functions enabled by
the authority level they have in the area to which the
command...

Page 59

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 59
Bosch Security Systems | 1/04 | 47775E
2.11.3 Authority Level Selections
Use Section 2.11.3 Authority Level Selections to
determine which Authority Level can access
command center functions that are Passcode
Protected. You do not need to select Enable items
in the Authority Level section if the command
center function is disabled or enabled. There are two
selections you can use for each individual function
for the authority level you are...

Page 60

D9412G/D7412G | Program Entry Guide | 2.0 9000MAINEN | 60
Bosch Security Systems | 1/04 | 47775E
L## Perim Instant
Default:See Program Record Sheet
Selection:Blank or E
#4 Perimeter Instant Arm [COMMAND][2]
Instant arm all Perimeter points, including Delayed
points, only in the area where the command center
is assigned.
L## Perim Delay
Default:See Program Record Sheet
Selection:Blank or E
#5 Perimeter Delay Arm [COMMAND][3]
Delay arm all Perimeter Delay point responses only
in the area where the command...