D9412G/D7412G | Program Entry Guide | 5.0 RADXSKEDEN | 111 Bosch Security Systems | 1/04 | 47775E S## Door 1 [through 8] Default: NoYesEnable the reporting of No Entry Events for Door #. 24No Entry Events Off: The control panel can log No Entry Events when an invalid token is detected for a specific door. No Entry Events include No Entry-Secured, No Entry-Interlock, No Entry- Unknown ID, and No Entry-Level. These events can be directed to print at a local printer or report remotely through phone...
Page 112
D9412G/D7412G | Program Entry Guide | 5.0 RADXSKEDEN | 112 Bosch Security Systems | 1/04 | 47775E S## Time Default:00:00 Selection:HH:MM (hours and minutes) Enter the time that the sked executes. Make entries using a 24-hour clock (for example, 7:00 AM is entered as 07:00, 2:45 PM is entered as 14:45). Disabled skeds have a blank time. If you copy the control panel and the entry for this prompt is blank, but times were at one time programmed, the sked may be disabled from the command center using the...
Page 113
D9412G/D7412G | Program Entry Guide | 5.0 RADXSKEDEN | 113 Bosch Security Systems | 1/04 | 47775E S## Xept Holiday Default:No Selection:Yes or No Yes Prevent this sked from operating on the holidays identified in the specific Holiday Index(es) used with this sked. Specific Holiday Indexes are selected in this programming section and programmed in the next programming module. No This sked operates on holidays programmed in the Holiday Index(es) used with this sked. If no days of the week are programmed,...
Page 114
D9412G/D7412G | Program Entry Guide | 5.0 RADXSKEDEN | 114 Bosch Security Systems | 1/04 | 47775E Holiday Index 1 Default:No Selection:Yes or No Yes Use this date in Holiday Index 1. No Do not use this date in Holiday Index 1. Holiday Index 2 Default:No Selection:Yes or No Holiday Index 3 Default:No Selection:Yes or No Holiday Index 4 Default:No Selection:Yes or No 5.3.2 View Holidays The View Holidays section is a view only section provided for your convenience. Use View Holidays to review the dates you...
Page 115
D9412G/D7412G | Program Entry Guide | 6.0 RADXAUX1EN | 115 Bosch Security Systems | 1/04 | 47775E 6.0 RADXAUX1 6.1 Introduction The RADXAUX1 Handler is primarily used for programming Enhanced Communication capabilities for the 9000 Series Control Panels. As new features (that require new programmable prompts) are added, they will most likely be added to a new revision of this handler. “Enhanced communications” represents the ability to provide new communication functions for the control panels using the...
Page 116
D9412G/D7412G | Program Entry Guide | 6.0 RADXAUX1EN | 116 Bosch Security Systems | 1/04 | 47775E 9133 Supervision Default:No Selection:Yes or No Yes Supervise the D9133 Serial Interface Module. No Do not supervise the D9133 Serial Interface Module. This item determines whether the D9133 Serial Interface Module is supervised or not. If the D9133 is supervised, disconnecting the D9133 from the control panel creates a Trouble SDI 80 Event and the command center annunciates a trouble tone (if programmed)...
Page 117
D9412G/D7412G | Program Entry Guide | 6.0 RADXAUX1EN | 117 Bosch Security Systems | 1/04 | 47775E • Provide for local programming by a D9133 Serial Interface Module. Although not listed in this section, RPS still checks for the RAM Passcode (see Section 2.7 RAM Parameters), Datalock Code, and the control panel type to determine if this RAM session should continue.6.4.1 User Interface Modifications for COMMAND 43 COMMAND 43 was modified to compensate for the ability to communicate with RPS by a network...
Page 118
D9412G/D7412G | Program Entry Guide | 6.0 RADXAUX1EN | 118 Bosch Security Systems | 1/04 | 47775E When configuring this item to allow for local programming, the D9133 needs Jumper 8 shorted, power must be cycled after changing the address, and a standard serial modem cable is required. Call Back Enabled Default:No Selection:Yes or No Yes When the control panel hears the proper RAM password (see RAM Passcode in Section 2.7 RAM Parameters), it ends the SDI RAM session and then attempts to reconnect to...
Page 119
D9412G/D7412G | Program Entry Guide | 6.0 RADXAUX1EN | 119 Bosch Security Systems | 1/04 | 47775E Both the U.S.Robotics V.92 56 K Modem (model # 5686, includes V.92 and V.90 56 K standard technology) and the Best Data Smart One V.92/V.44 56 K External Data/Fax Modem (model # 56SX-92) are recommended for use as external modems (connected to the control panel) based on compatibility testing by Bosch Security Systems. Other modules were either not tested or found compatible. The following seven prompts help...
Page 120
D9412G/D7412G | Program Entry Guide | 6.0 RADXAUX1EN | 120 Bosch Security Systems | 1/04 | 47775E Figure 7: Com Port Selection within HyperTerminal Figure 8: External Modem Connection P3 P2 1248SERRXTXRXTXBUSSDI PW R SDI A SDI B SDI COM D9133DC 1 2 3 2 56 4 1 - RPS Remote Account Manager 2 - Modem 3 - PSTN4 - D9412G/D7412G Control Panel 5 - Standard serial cable 6 - SDI bus