Page 111

D9412G/D7412G | Program Entry Guide | 5.0 RADXSKEDEN | 111
Bosch Security Systems | 1/04 | 47775E
S## Door 1 [through 8]
Default: NoYesEnable the reporting
of No Entry Events
for Door #.
24No Entry Events Off: The control
panel can log No Entry Events
when an invalid token is detected
for a specific door. No Entry
Events include No Entry-Secured,
No Entry-Interlock, No Entry-
Unknown ID, and No Entry-Level.
These events can be directed to
print at a local printer or report
remotely through phone...

Page 112

D9412G/D7412G | Program Entry Guide | 5.0 RADXSKEDEN | 112
Bosch Security Systems | 1/04 | 47775E
S## Time
Default:00:00
Selection:HH:MM (hours and minutes)
Enter the time that the sked executes. Make entries
using a 24-hour clock (for example, 7:00 AM is
entered as 07:00, 2:45 PM is entered as 14:45).
Disabled skeds have a blank time. If you copy the
control panel and the entry for this prompt is blank,
but times were at one time programmed, the sked
may be disabled from the command center using the...

Page 113

D9412G/D7412G | Program Entry Guide | 5.0 RADXSKEDEN | 113
Bosch Security Systems | 1/04 | 47775E
S## Xept Holiday
Default:No
Selection:Yes or No
Yes Prevent this sked from operating on
the holidays identified in the specific
Holiday Index(es) used with this sked.
Specific Holiday Indexes are selected
in this programming section and
programmed in the next programming
module.
No This sked operates on holidays
programmed in the Holiday Index(es)
used with this sked.
If no days of the week are programmed,...

Page 114

D9412G/D7412G | Program Entry Guide | 5.0 RADXSKEDEN | 114
Bosch Security Systems | 1/04 | 47775E
Holiday Index 1
Default:No
Selection:Yes or No
Yes Use this date in Holiday Index 1.
No
Do not use this date in Holiday Index
1.
Holiday Index 2
Default:No
Selection:Yes or No
Holiday Index 3
Default:No
Selection:Yes or No
Holiday Index 4
Default:No
Selection:Yes or No
5.3.2 View Holidays
The View Holidays section is a view only section
provided for your convenience. Use View Holidays
to review the dates you...

Page 115

D9412G/D7412G | Program Entry Guide | 6.0 RADXAUX1EN | 115
Bosch Security Systems | 1/04 | 47775E
6.0 RADXAUX1
6.1 Introduction
The RADXAUX1 Handler is primarily used for
programming Enhanced Communication capabilities
for the 9000 Series Control Panels. As new features
(that require new programmable prompts) are
added, they will most likely be added to a new
revision of this handler.
“Enhanced communications” represents the ability
to provide new communication functions for the
control panels using the...

Page 116

D9412G/D7412G | Program Entry Guide | 6.0 RADXAUX1EN | 116
Bosch Security Systems | 1/04 | 47775E
9133 Supervision
Default:No
Selection:Yes or No
Yes Supervise the D9133 Serial Interface
Module.
No
Do not supervise the D9133 Serial
Interface Module.
This item determines whether the D9133 Serial
Interface Module is supervised or not. If the D9133
is supervised, disconnecting the D9133 from the
control panel creates a Trouble SDI 80 Event and
the command center annunciates a trouble tone (if
programmed)...

Page 117

D9412G/D7412G | Program Entry Guide | 6.0 RADXAUX1EN | 117
Bosch Security Systems | 1/04 | 47775E
• Provide for local programming by a D9133
Serial Interface Module.
Although not listed in this section, RPS still checks
for the RAM Passcode (see Section 2.7 RAM
Parameters), Datalock Code, and the control panel
type to determine if this RAM session should
continue.6.4.1 User Interface Modifications for
COMMAND 43
COMMAND 43 was modified to compensate for the
ability to communicate with RPS by a network...

Page 118

D9412G/D7412G | Program Entry Guide | 6.0 RADXAUX1EN | 118
Bosch Security Systems | 1/04 | 47775E
When configuring this item to allow for
local programming, the D9133 needs
Jumper 8 shorted, power must be cycled
after changing the address, and a standard
serial modem cable is required.
Call Back Enabled
Default:No
Selection:Yes or No
Yes
When the control panel hears the
proper RAM password (see 
RAM
Passcode
 in Section 2.7 RAM
Parameters), it ends the SDI RAM
session and then attempts to reconnect
to...

Page 119

D9412G/D7412G | Program Entry Guide | 6.0 RADXAUX1EN | 119
Bosch Security Systems | 1/04 | 47775E
Both the U.S.Robotics V.92 56 K Modem
(model # 5686, includes V.92 and V.90
56 K standard technology) and the Best
Data Smart One V.92/V.44 56 K External
Data/Fax Modem (model # 56SX-92) are
recommended for use as external modems
(connected to the control panel) based on
compatibility testing by Bosch Security
Systems. Other modules were either not
tested or found compatible.
The following seven prompts help...

Page 120

D9412G/D7412G | Program Entry Guide | 6.0 RADXAUX1EN | 120
Bosch Security Systems | 1/04 | 47775E
Figure 7: Com Port Selection within HyperTerminal
Figure 8: External Modem Connection
P3
P2
1248SERRXTXRXTXBUSSDI
PW R
SDI
A
SDI
B
SDI
COM
D9133DC
1
2
3
2
56
4
1 - RPS Remote Account Manager
2 - Modem
3 - PSTN4 - D9412G/D7412G Control Panel
5 - Standard serial cable
6 - SDI bus 