Amanda Work Group Installation Manual
Have a look at the manual Amanda Work Group Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 32 Amanda manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Chapter 17: Installing the Clients 177 5. Follow the directions given by the setup program to finish the installa- tion process. Unless modified by the installer, the directory C:\AMACLNTS stores the clients. After the installation, an Amanda icon appears in Program Manager. The Amanda group displays all the clients installed on this workstation. Installing from a Floppy Drive on Windows 95 To install either user or administrator clients: 1. If any previously installed Amanda Clients are running, close them. 2. Insert the appropriate [email protected]/DOS installation disk into the floppy drive. 3. Select the Start button and then select Run. 4. At the Command Line, type A:SETUP then click OK. 5. Follow the directions given by the setup program to finish the installa- tion process. Unless modified by the installer, the directory C:\AMACLNTS contains the clients. The Amanda group of clients appears in the Programs section of the Start menu. The Amanda group contains all the clients installed on this workstation.
178 Installing [email protected]/DOS Adding Client Connections Now that users have the [email protected]/DOS clients, you must add the appropriate number of Client Connections to the Amanda Voice Server. Only one client connection comes with Amanda Voice Server. If you add no client connections, only one client can access the voice server at a time. Adding client connections requires a Client Connection Bank (CCB) with at least as many connections as you wish to install at this site. 432 To Printer Port CCB Modem Voice Board VGA CardCOM1 COM2
Chapter 17: Installing the Clients 179 To add client connections: 1. If Amanda is running, shut down the Amanda system and turn the computer off. a. Press Alt+S (if Amanda is running as a standalone) or s (if Amanda is running as a voice server). b. Type in the password. (The default is AMandA with only the first two and the last letter capitalized.) c. Press Enter. d. Press Y (to confirm the shutdown). e. Press Y again (to reconfirm). f. When you reach the DOS prompt C:\AMANDA>, turn the com- puter off. 2. Next, attach the CCB to the parallel port on the back of Amanda Voice Server. The CCB contains a number of Client Connections, some (or all) of which can be transferred to this Voice Server. 3. Turn Amanda Voice Server on. During the start up process, the system asks: Do you want to run [email protected]/DOS? Press Y or N 4. Press Y for Yes. Amanda detects the CCB and asks for the number of connections to be added to this Voice Server. 5. Enter the requested number and follow the prompts to turn off the com- puter and remove the CCB. 6. After removing the CCB, turn Amanda Voice Server back on. 7. During the start up process, the system asks: Do you want to run [email protected]/DOS? Press Y or N
180 Installing [email protected]/DOS 8. Press Y for Yes. 9. This brings Amanda Voice Server and the appropriate number of client connections online. Reviewing Client Connections Each time a user logs onto Amanda Messenger or Amanda Dialer, or the system administrator logs onto Amanda Administrator or Monitor, he acquires a client connection. When he logs off, the client connection is returned to the pool and is available for the next person who logs on. As more users are added to Amanda, some users may not be able to log on because all client connections are in use. To display the maximum number of clients Amanda is configured for: 1. Run Amanda Monitor. 2. On the File menu, click Copy…. The Copy dialog box appears.
Chapter 17: Installing the Clients 181 3. Type C:\AMANDA\INSTALL.CFG. 4. Select the Voice Server option button to indicate the location of the file. 5. Indicate the name and location of the file to be created. If the file is on your workstation (or network), you can click Browse… to locate the file. 6. Select the Local option button to indicate the location of the new file. 7. Click Copy. If the file already exists, the Confirm File Replace dialog box appears. 8. Do one of the following: To replace the existing file, click Yes. To preserve the existing file, click No and type a unique name for your file in the Copy dialog box. 9. When “File copy completed” appears at the bottom of the Copy dialog box, click Cancel. 10. View the file using a text editor. The value for n_clients is the maximum number of clients the Amanda server currently accepts. Do not edit this value and recopy install.cfg to the voice server. Changing this value will corrupt the file.
Chapter 18: Configuration Reference General Options Configuration OptionDescription abbreviate_datesControls how Amanda says the date for a message dated today or yesterday. True or False. The default is True. When True, Amanda says “today” or “yesterday” instead of the actual date, for ex- ample, “November 27 th , 1996.” When False, Amanda says only the actual date, such as “November 27 th , 1996.” The default appears in install.cfg as: set abbreviate_dates true abbreviate_greetingAllows you to shorten the system greeting. True or False. The default is False. When True, Amanda says, “Please leave a message at the tone.” This is the short- ened version of the system greeting. When False, Amanda says, “Please leave a message for” followed by the name and extension recording. This is the usual default version of the system greeting. The default appears in install.cfg as: set abbreviate_greeting false activation_keyA number you receive from your Amanda Company sales representative to activate your system. You must set this option if one or more of your voice boards were not purchased from The Amanda Company. If you change or add a board later, you need another activation key because the key is based on the serial numbers for all of the boards and the total number of ports. The default is 0, which means there is no activation key. The default appears in install.cfg as: set activation_key 0
184 Installing [email protected]/DOS active_holdWhen the extension is busy, the caller can hold for the called party—actively or in- actively. True or False. The default is True. When True, Amanda is set up for active hold. The caller must continually indicate that he wants to remain on hold. Failure to continue to press * when prompted indi- cates that the caller is no longer interested in holding. If he doesn’t enter another ex- tension, he is asked for a message. Active hold is best for 800 numbers, support lines, or when Amanda is used as an Automatic Call Distribution (ACD) device. It prevents a caller from pressing * to go on hold and staying on hold indefinitely with- out further interaction. The caller presses * to go on hold and must press * periodi- cally to stay on hold. When False, Amanda is set up for inactive hold. The caller indicates that he wants to be on hold only once. If the caller does nothing, Amanda retries the extension until it is no longer busy. The caller can also enter another extension or press * to leave a message. In this case, the user uses * to go on hold and * to leave a message. See also auto_queue. The default appears in install.cfg as: set active_hold true adpcm_hqSets the sampling rate for outgoing greetings. The higher the sampling rate, the bet- ter the sound quality, but also the more disk space used. 24, 32, or 64. The default (and recommended value) is 64. N OTE: If you change this on an active system, all previously recorded outgoing greetings need to be re-recorded. The default appears in install.cfg as: set adpcm_hq 64 adpcm_nqSets the sampling rate for incoming messages. The higher the sampling rate, the bet- ter the sound quality, but also the more disk space used. 24, 32, or 64. The default (and recommended value) is 32. N OTE: If you change this on an active system, you should have users delete all their messages first. The default appears in install.cfg as: set adpcm_nq 32 General Options (Continued) Configuration OptionDescription
Chapter 18: Configuration Reference 185 adpcm_pqSets the sampling rate for the system prompt file. This is set to the sampling rate at which the system prompt file was recorded. 24, 32, or 64. Correctly set by default. N OTE: Do not change this unless you have installed the appropriate system prompt file. The default appears in install.cfg as: set adpcm_pq x where x is the correct setting for your prompt files. advertisingDisplays a text string at different locations on the Main screen after the screen saver starts up. (This option does not apply to Amanda voice server.) Use any text string ranging from 0 to 79 characters. The recommended length is less than 30 characters so your message is easy to read and fits on the screen at most lo- cations. Buy more AMandAs! is the default. See also tmo_blank. The default appears in install.cfg as: set advertising Buy more Amandas! ati_modeAllows Amanda to be used with a Brooktrout x000 board and an ATI board. An ATI board requires a version 7.x Brooktrout driver. True or False. The default is false. When True, Amanda makes the connections needed for the ATI board. When False, Amanda does not make the ATI connections. The default appears in install.cfg as: set ati_mode false C AUTION: RTNI-xATI voice boards cannot detect rotary. If you use an RTNI- xATI voice board, you must leave the rotary configuration option set to false. General Options (Continued) Configuration OptionDescription
186 Installing [email protected]/DOS auto_queueDesigned for callers with rotary telephones so that they can be put “on hold” without having to press *. True or False. The default is False. If True and if active_hold is False, callers are automatically put “on hold” when they reach a busy extension. A custom busy message must explain what’s going on so that callers are aware that they are “on hold” and that they can dial other exten- sions—if they prefer. The default appears in install.cfg as: set auto_queue false auto_reportThe name of a previously saved report file in the RPT.DB subdirectory within the AMANDA directory which can be executed and printed once each day. When not set, no auto reporting is done. Use the name of a report file with the extension .RPT. The default is an empty string which means that no report file is executed. To use this feature, verify the following: A printer with a parallel interface must be connected to Amanda The parameter lpt_port must be set to 1, indicating the port to which the printer is attached The printer must be online and have enough paper See also auto_report_time and lpt_port. The default appears in install.cfg as: set auto_report auto_report_timeThe time of day at which the report is to be printed (when auto_report is not an emp- ty string). A time of day in 24-hour MMHH format. The default is 0745 (7:45 a.m.). See also auto_report and lpt_port. The default appears in install.cfg as: set auto_report_time 0745 General Options (Continued) Configuration OptionDescription