STARPLUS @ SPD 4896Digital Key Telephone SystemINSTALLATION Figure 500-14 Digital Terminal Wall MountingIssue 1, March 1994500-23
Page 212
STARPLUS @ SPD 4696 Digital Key Telephone System INSTALLATlONSLT device. Additionally, a CO line may be wired to the second pair of the SLT modular connector for Power fail operation. Cable Loop Limits:The maximum loop limit from the KSU to the SLA (OPX) adapter is 1000 feet. The maximum loop limit from the SLA (OPX) adapter to the connected SLT or device is 1400 ohms not including the telephone or device. 500.6POWER FAILURE TRANSFER A.Relay / Sensor Interface ModuleThe Relay Sensor Interface Module...
Page 213
STARPLUS @ SPD 48% Digital Key Telephone SystemINSTALLATION GREENl-r TRRT RR! I iiI STATIONI/(jCONNECTING ! IBLOCK MODULAR: I CABLE L-L!- - MDFPFT Ring j SLT Ring1 / PFTTip/ / SLTTip ,-KSU n”un Customer Provided-48V dc Power Supplyl/2 amp per OPX unit 9‘,-.--JGreen to Phone Red to Phone BlacK to Trunk Tip Yellow !o Trunk Ring Figure 500-15 Off-Premise Extension (OPX) Module Issue 1, March 1994 500-25
Page 214
INSTALLATIONSTARPLUS @ SPD 4896 Digital Key Telephone System XMIT TIP XMIT RINGRCVE TIP RCVE RING STATION CONNECTING BLOCK :.;,MODULAR CABLE I / - RELAY ’/ SENSOR // 1 Device Output Relay 1 (dry contacts)/ (ie: RAN Device) / j Loud Bell Control1 External Page Device RAN Device 1 Power Failure Transfer ! Starpius Tri-Output 124 VDCI Power Supply , 1 Amp Max. I / or 24VDC 1 Amp Power Supply (Customer Provided)NOTE: RAN device does notrequire external power supplyFigure 500-16 Relay / Sensor...
Page 215
STARPLUS @ SPD 4896 Digital Key Telephone SystemINSTALLATION L OPXI II IIPFT TIPINCO 1 TIP IN ,------------------CO 1 RING IN _____-___-____ PFI- RING SLT RING (SLT or DEVICE), iiMethod #I Power Failure Transfer Unit (P-U)Method #2Customer Provtded Battery + -RELAY / SENSOR INTERFACE MODULE 12VDC1AMPI,’ ,nCOM i ]:b :r--,/ ~ N.C. CONTACT / - ‘>m-.’ :1-bI-j Multi-Purpose RelayFigure 500-17 Power Failure Transfer Wiring Options Issue 1, March 1994 500-27
Page 216
INSTALLATIONsTAFlPLUi@ SPD 48%Digital Key Telephone System POWER FAILURE TRANSFER UNIT (PFTU),----------------__CHAMP CONN 1 STAl TIP OUT..-___-.--___-__- WMjN -w STAl RING OUT ISIX CIRCUITS I I I I I I I I I II i I II I I I I I I I I I I I I I I II II I I --------------____IFigure 500-18 Power Failure Transfer Circuit 500-28 issue 1, March 1994
Page 217
STARPLUS @ SPD 4896 Digital Key Telephone SystemINSTALLATION Table 500-4 PFlIJ Conn A Connecting Block T- i-‘piiI I 1/ 2 : 3fI ! 4 / 5 PIN 26 127 2 28 3 294 30 5 31 6 32 7 33 834 9 35 10 36 11 37 12 38 13COLOR WH/BLBUWH WH/OR OR/WH WH/GN GN/WH WH/BN BN/WH WH/SL SLIWH RD/BL BURD RD/OR OR/RD RD/GN GN/RD RD/BN BN/RD RD/SL SURD BK/BLBUBK BWOR OR/BK BWGN GN/BK SK/BN BN/BK BWSLSUBK YUBL BLIYLYUOR OPl/YLYUGN GNNL YUBN BNNL YUSL SUYL VIIBLBWI VI/OR ORNI DESIG 1TIT 1TIR 1STAINTIP 1 STA IN RING 1 TRK OUT...
Page 218
INSTALLATIONSTARPLUS @ SPD 4896 Digital Key Telephone System500.9INSTALLING RECORDED AN- NOUNCEMENT DEVICE (RAN) The Recorded Announcement feature (RAN) is used with either the Automatic Call Distribution (ACD) or Uniform Call Distribution (UCD) features to provide unanswered incoming CO calls or calls in queue witha Recorded Announcement while waiting for an available ACD or UCD station. The system may be programmed to provide this announcement on specified RAN output ports on the system (unused SLT...
Page 219
STARPLUS @ SPD 4996 Digital Key Telephone SystemINSTALLATION 500.10 DATAFEATURE The Data Feature is a time division switched, point to point data transmission capability which permits simultaneous (on the same system but not the sameport) voice and data communications. The Data Feature offers the ability to transmit data information between personal computers, printers, plotters, CRT terminals, and main frame computer ports. To establish a Data call, a Digital Data interface Unit (DDIU) is required to be...
Page 220
INSTALLATION STARPLUS @ SPD 4896 Digital Key Telephone SystemConnection of the individual data communication devices requires that the installer be familiar with data communications terms, and has access to the appropriate information for connecting the variety of data communications devices that may be encoun- tered. This information consists of, but is not limited to:1. Is the device configured as data terminal equipment (DTE), or data communications equipment (DCE. 2. What pin on the RS-232C type...