Page 211

STARPLUS @ SPD 4896Digital Key Telephone SystemINSTALLATION
Figure 500-14 Digital Terminal Wall MountingIssue 1, March 1994500-23 

Page 212

STARPLUS @ SPD 4696
Digital Key Telephone System
INSTALLATlONSLT device. Additionally, a CO line may be
wired to the second pair of the SLT modular
connector for Power fail operation.
Cable Loop Limits:The maximum loop limit from the KSU to the
SLA (OPX) adapter is 1000 feet.
The maximum loop limit from the SLA (OPX)
adapter to the connected SLT or device is 1400
ohms not including the telephone or device.
500.6POWER FAILURE TRANSFER
A.Relay 
/ Sensor Interface ModuleThe Relay Sensor Interface Module...

Page 213

STARPLUS @ SPD 48%
Digital Key Telephone SystemINSTALLATION
GREENl-r
TRRT
RR!
I
iiI  STATIONI/(jCONNECTING
! IBLOCK
MODULAR:  I
CABLE
L-L!- -
MDFPFT Ring j
SLT Ring1  /  
PFTTip/
/  
SLTTip
,-KSU
n”un Customer Provided-48V dc Power Supplyl/2 amp per OPX unit
9‘,-.--JGreen to Phone
Red to Phone
BlacK to Trunk Tip
Yellow 
!o Trunk Ring
Figure 500-15 Off-Premise Extension 
(OPX) Module
Issue 1, March 1994
500-25 

Page 214

INSTALLATIONSTARPLUS @ SPD 4896
Digital Key Telephone System
XMIT TIP
XMIT RINGRCVE TIP
RCVE RING
STATION
CONNECTING
BLOCK
:.;,MODULAR
CABLE
I
/
- RELAY
’/ SENSOR //
1  Device Output Relay 1
(dry contacts)/  (ie: RAN Device) /
j
Loud Bell Control1  External Page Device
RAN Device
1  Power Failure Transfer
!  
Starpius Tri-Output
124 VDCI
Power Supply ,
1 Amp Max.
I
/
or 24VDC 1 Amp Power Supply
(Customer Provided)NOTE: RAN device does notrequire external power supplyFigure 
500-16 Relay / Sensor...

Page 215

STARPLUS @ SPD 4896
Digital Key Telephone SystemINSTALLATION
L
OPXI
II IIPFT TIPINCO 1 TIP IN
,------------------CO 1 RING IN
_____-___-____
PFI- RING
SLT RING
(SLT or DEVICE),
iiMethod 
#I
Power Failure Transfer Unit (P-U)Method #2Customer
Provtded
Battery
+ -RELAY / SENSOR
INTERFACE MODULE
12VDC1AMPI,’ ,nCOM i  
]:b :r--,/ ~
N.C. CONTACT /  
- ‘>m-.’ :1-bI-j
Multi-Purpose RelayFigure 500-17 Power Failure Transfer Wiring Options
Issue 1, March 1994
500-27 

Page 216

INSTALLATIONsTAFlPLUi@ SPD 48%Digital Key Telephone System
POWER FAILURE TRANSFER UNIT 
(PFTU),----------------__CHAMP CONN 1
STAl TIP OUT..-___-.--___-__- WMjN -w
STAl RING OUT
ISIX CIRCUITS
I
I
I
I
I
I
I
I
I
II
i
I
II
I
I
I
I
I
I
I
I
I
I
I
I
I
I
II
II
I
I
--------------____IFigure 500-18 Power Failure Transfer Circuit
500-28
issue 
1, March 1994 

Page 217

STARPLUS @ SPD 4896
Digital Key Telephone SystemINSTALLATION
Table 
500-4 PFlIJ Conn A Connecting Block
T-
i-‘piiI
I  
1/  2
:  3fI
!
4
/
5
PIN
26
127
2
28
3
294
30
5
31
6
32
7
33
834
9
35
10
36
11
37
12
38
13COLOR
WH/BLBUWH
WH/OR
OR/WH
WH/GN
GN/WH
WH/BN
BN/WH
WH/SL
SLIWH
RD/BL
BURD
RD/OR
OR/RD
RD/GN
GN/RD
RD/BN
BN/RD
RD/SL
SURD
BK/BLBUBK
BWOR
OR/BK
BWGN
GN/BK
SK/BN
BN/BK
BWSLSUBK
YUBL
BLIYLYUOR
OPl/YLYUGN
GNNL
YUBN
BNNL
YUSL
SUYL
VIIBLBWI
VI/OR
ORNI
DESIG
1TIT
1TIR
1STAINTIP
1 STA IN RING
1 TRK OUT...

Page 218

INSTALLATIONSTARPLUS @ SPD 4896
Digital 
Key Telephone System500.9INSTALLING RECORDED AN-
NOUNCEMENT DEVICE (RAN)
The Recorded Announcement feature (RAN) is used
with either the Automatic Call Distribution (ACD) or
Uniform Call Distribution (UCD) features to provide
unanswered incoming CO calls or calls in queue witha Recorded Announcement while waiting for an
available ACD or UCD station. The system may be
programmed to provide this announcement on
specified RAN output ports on the system (unused
SLT...

Page 219

STARPLUS @ SPD 4996
Digital Key Telephone SystemINSTALLATION
500.10
DATAFEATURE
The Data Feature is a time division switched, point
to point data transmission capability which permits
simultaneous (on the same system but not the sameport) voice and data communications. The Data
Feature offers the ability to transmit data information
between personal computers, printers, plotters, CRT
terminals, and main frame computer ports.
To establish a Data call, a Digital Data interface Unit
(DDIU) is required to be...

Page 220

INSTALLATION
STARPLUS @ SPD 4896
Digital Key Telephone SystemConnection of the individual data communication
devices requires that the installer be familiar with
data communications terms, and has access to the
appropriate information for connecting the variety of
data communications devices that may be encoun-
tered. This information consists of, but is not limited
to:1. Is the device configured as data terminal
equipment (DTE), or data communications
equipment (DCE.
2. What pin on the RS-232C type...
Start reading Vodavi Starplus Spd 4896 Hybrid Key Telephone System Installation Manual

Related Manuals for Vodavi Starplus Spd 4896 Hybrid Key Telephone System Installation Manual

All Vodavi manuals