STARPLUS @ SPD 4996 Digital Key Telephone SystemGENERAL DESCRIPTION l The system capacities are listed in Table 400-l Digital System Capacities. 0Electrical specifications are listed in Table 400-2 Electrical Specifications.l Environmental specifications are iisted in Table 400-3 Environmental Specifications. lLoop limits are listed in Table 400-4 Loop Limits. 0 Dialing specifications are listed in Table 400-5Dialing Specifications. l FCC Registrations Numbers are listed in Table 400-6 FCC Registration...
Page 182
GENERAL DESCRIPTION STARPLUS @ SPD 4896 Digital Key Telephone System Table 400-l Digital System CapacitiesTime Slots:144 PCM/TDM time slots Ports: CO/PBWCentrex Lines Digital Terminal Stations/ 48 (max.) loop start (12 per CO1 2 board) /96 (max.) Digital Terminals (12 per KT12 board) Standard Single Line Telephones184 (max.) Standard 2500 type SLTs (12 per SLI 2 board) Off-Premise Extensions Paging: (one way paging)/ 96 (max.) OPX Stations (1 per single line adapter (OPX)) Internal Paging 1 4 (max.)...
Page 183
STARPLUS @ SPD 4996Digital Key Telephone SystemGENERAL DESCRIPTION Table 400-2 Electricai Specifications AC Input to Power Supply:117V ac + lo%, 60 Hz single phase Power Consumption: Power Supply Fuse - AC input Longitudinal Balance: Idle Channel Noise: Cross Talk Attenuation: Single Frequency Distortion: (300 Hz - 3400 Hz) Ringing Sensitivity: Ringer Equivalence Number: (REN) CO Line Signaling - DTMF: Music Source (input) Contact Rating Multi Purpose Relay External Page Port Output Impedance Output...
Page 184
GENERAL DESCRIPTIONSTARPLUS @ SPD 4696 Digital Key Telephone SystemTable 400-4 Loop Limits Electronic Telephone: (including DSS/DLS Console)1000 feet of 26 AWG Cable 1000 feet of 24 AWG Cable 1000 feet of 22 AWG Cable Standard Single Line TelephonesI 2000 feet of 24 AWG Cable Off-Premise Extensions (OPX) (Adapter to SLT)1400 Ohms maximum loop, not including telephone. Table 400-5 Dialing Specifications DTMF Dialing Frequency Deviation Rise Time Duration of DTMF Signal Interdigit Time PULSE Dialing...
Page 185
STARPLUS @ SPD 4896 Digital Key Telephone SystemGENERAL DESCRIPTION dTable 400-8 Dimensions and Weight KEY SERVICE UNIT Height 16” Width26” Depth 15”Weight42 Ibs. (unloaded) POWER SUPPLY Height 14.5” Width7.25” Depth 6”Weight 19.5 Ibs.OFF-PREMISE EXTENSION MODULE (OPX) Height 1.75” Width7.625” Length8.0” Weight 3.5 Ibs. REMYISENSOR MODULEDDIU UNIT Height 1.75” Width7.625” Length 8.0” Weight 3.5 Ibs.TRI-OUTPUT SUPPLY Height 9” Width4” Length8.25” Weight 10 Ibs.j 34-BUT-TON ENHANCED TERMINAL Height3.5”...
Page 186
GENERAL DESCRIPTION STARPLUS @ si=D 4696 Digital Key Telephone System Table 400-10 Digital Terminal Audible SignalsTYPE OF SIGNAL Key Teleohone Sianals: Incoming CO tine Intercom Tone Ringing Intercom Call Announce 6-wTransferred CO Line CO Line Recall Message Wait Call Back Message Wait Reminder Tone CO Queue Call Back Camp-on Paging Alert ToneI f FREQUENCY !SIGNAL DURATION I/ 1 1215/14710.8s on/2.4s off; repeated 1215/14710.4s oni0.4s 0fflOAs on/2.0s off 9350.2s on/0.2s off (2 bursts) 1215/147...
Page 187
STARPLUS @ St’D 4696 Digital Key Telephone SystemGENERAL DESCRIPTION Table 400-12 OPX Telephone Audible Signals TYPE OF SIGNAL OPX Sionals:incoming CO tine Intercom Ringing Transferred CO Line CO Line Recall CO Queue Call BackI IFREQUENCY /SIGNAL DURATION I 30 Hz, 50-9OV AC2.0s on/4.os off 30 Hz, 50-9OV AC2.0s on/4s off 30 Hz, 50-9OV AC2.0s on/4.0s off 30 Hz, 50-9OV AC2.0s on/4.0s off 30 Hz, 50-9OV AC2.0s on/4.0s off OPX Confidence Tones:* Intercom RingbackBusy Tone Error Tone intercom Dial Tone...
Page 188
STARPLUS @ SPD 4896 GENERAL DESCRIPTION Digital Key Telephone SystemTable 400-13 DSS/BLF Button Visual Indicators TYPE OF SIGNAL Off-Hook/Busy (All Stations) Incoming Intercom Ring (Destination) Call Announce (Destination) Message Waiting Call Back (Destination) Do Not Disturb (All Stations) Automatic Call Back (Destination) ACDAJCD Available/Unavailable ACD Overflow Station Available/UnavailableINDICATOR FLASH RATES Steady 120 ipm flutter (Default) steady 120 ipm flutter 480 ipm triple wink 120 ipm...
Page 189
STARPLUS @ SPD 4896 Digital Key Telephone SystemINSTALLATIONSECTION 500 INSTALLATION 500.1SITE PLANNING Selection of a suitable location is the most basic, yetmost critical consideration in the installation of a telephone system. The following should be consid- ered when choosing an appropriate location for equipment installation: 0 Ample space must be allowed to remove the KSU cover, to access assemblies and cards within the cabinet and allow space for the MDF (Main Distribution Frame). lLocation of...
Page 190
INSTALLATlON STARPLUS@ SPD 4896Digital Key Telephone System proper installation can be a serious safety haz- ard.Failure to provide the proper lightning protec- tion will increase maintenance expense and require more available spare parts. 500.2 INSTALLAnON PLANNING FOR THE SPD 4696 SYSTEM Prior planning of the installation will aid in a smooth cut-over and a satisfied customer. Select a suitable location for the system. Determine the number of telephones of each type, and the number of Key Telephone...