Page 181

STARPLUS @ SPD 4996
Digital Key Telephone SystemGENERAL DESCRIPTION
l The system capacities are listed in Table 400-l
Digital System Capacities.
0Electrical specifications are listed in Table 400-2
Electrical Specifications.l Environmental specifications are iisted in Table
400-3 Environmental Specifications.
lLoop limits are listed in Table 
400-4 Loop Limits.
0 Dialing specifications are listed in Table 400-5Dialing Specifications.
l FCC Registrations Numbers are listed in Table
400-6 FCC Registration...

Page 182

GENERAL DESCRIPTION
STARPLUS @ SPD 4896
Digital Key Telephone System
Table 400-l Digital System CapacitiesTime Slots:144 
PCM/TDM time slots
Ports:
CO/PBWCentrex Lines
Digital Terminal Stations/  48 (max.) loop start (12 per CO1 2 board)
/96 (max.) Digital Terminals (12 per KT12 board)
Standard Single Line Telephones184 (max.) Standard 2500 type 
SLTs (12 per SLI 2 board)
Off-Premise Extensions
Paging: (one way paging)/  96 (max.) OPX Stations (1 per single line adapter (OPX))
Internal Paging
1  4 (max.)...

Page 183

STARPLUS @ SPD 4996Digital Key Telephone SystemGENERAL DESCRIPTION
Table 400-2 
Electricai Specifications
AC Input to Power Supply:117V ac + lo%, 60 Hz single phase
Power Consumption:
Power Supply Fuse 
- AC input
Longitudinal Balance:
Idle Channel Noise:
Cross Talk Attenuation:
Single Frequency Distortion:
(300 Hz 
- 3400 Hz)
Ringing Sensitivity:
Ringer Equivalence Number: (REN)
CO Line Signaling 
- DTMF:
Music Source (input)
Contact Rating
Multi Purpose Relay
External Page Port
Output Impedance
Output...

Page 184

GENERAL DESCRIPTIONSTARPLUS @ SPD 4696
Digital Key Telephone SystemTable 400-4 Loop Limits
Electronic Telephone:
(including 
DSS/DLS Console)1000 feet of 26 AWG Cable
1000 feet of 24 AWG Cable
1000 feet of 22 AWG Cable
Standard Single Line TelephonesI  2000 feet of 24 AWG Cable
Off-Premise Extensions (OPX) (Adapter to 
SLT)1400 Ohms maximum loop, not including telephone.
Table 400-5 Dialing Specifications
DTMF Dialing
Frequency Deviation
Rise Time
Duration of DTMF Signal
Interdigit Time
PULSE Dialing...

Page 185

STARPLUS @ SPD 4896
Digital Key Telephone SystemGENERAL DESCRIPTION
dTable 400-8 Dimensions and Weight
KEY SERVICE UNIT
Height
16”
Width26”
Depth
15”Weight42 
Ibs. (unloaded)
POWER SUPPLY
Height
14.5”
Width7.25”
Depth
6”Weight
19.5 Ibs.OFF-PREMISE EXTENSION MODULE (OPX)
Height
1.75”
Width7.625”
Length8.0”
Weight
3.5 Ibs.
REMYISENSOR MODULEDDIU UNIT
Height
1.75”
Width7.625”
Length 8.0”
Weight
3.5 Ibs.TRI-OUTPUT SUPPLY
Height
9”
Width4”
Length8.25”
Weight
10 Ibs.j  
34-BUT-TON ENHANCED TERMINAL
Height3.5”...

Page 186

GENERAL DESCRIPTION
STARPLUS @ si=D 4696
Digital Key Telephone System
Table 400-10 Digital Terminal Audible SignalsTYPE OF SIGNAL
Key Teleohone Sianals:
Incoming CO tine
Intercom Tone Ringing
Intercom Call Announce
6-wTransferred CO Line
CO Line Recall
Message Wait Call Back
Message Wait Reminder Tone
CO Queue Call Back
Camp-on
Paging Alert ToneI
f
FREQUENCY !SIGNAL DURATION
I/
1
1215/14710.8s on/2.4s off; repeated
1215/14710.4s oni0.4s 0fflOAs on/2.0s off
9350.2s on/0.2s off (2 bursts)
1215/147...

Page 187

STARPLUS @ St’D 4696
Digital Key Telephone SystemGENERAL DESCRIPTION
Table 400-12 OPX Telephone Audible Signals
TYPE OF SIGNAL
OPX 
Sionals:incoming CO tine
Intercom Ringing
Transferred CO Line
CO Line Recall
CO Queue Call BackI
IFREQUENCY /SIGNAL DURATION
I
30 Hz, 
50-9OV AC2.0s on/4.os off
30 Hz, 
50-9OV AC2.0s on/4s off
30 Hz, 
50-9OV AC2.0s on/4.0s off
30 Hz, 
50-9OV AC2.0s on/4.0s off
30 Hz, 
50-9OV AC2.0s on/4.0s off
OPX Confidence Tones:*
Intercom 
RingbackBusy Tone
Error Tone
intercom Dial Tone...

Page 188

STARPLUS @ SPD 4896
GENERAL DESCRIPTION
Digital Key Telephone SystemTable 400-13 
DSS/BLF Button Visual Indicators
TYPE OF SIGNAL
Off-Hook/Busy (All Stations)
Incoming Intercom Ring (Destination)
Call Announce (Destination)
Message Waiting Call Back (Destination)
Do Not Disturb (All Stations)
Automatic Call Back (Destination)
ACDAJCD Available/Unavailable
ACD Overflow Station Available/UnavailableINDICATOR FLASH RATES
Steady
120 ipm flutter (Default)
steady
120 ipm flutter
480 ipm triple wink
120 ipm...

Page 189

STARPLUS @ SPD 4896
Digital Key Telephone SystemINSTALLATIONSECTION 500
INSTALLATION
500.1SITE PLANNING
Selection of a suitable location is the most basic, yetmost critical consideration in the installation of a
telephone system. The following should be consid-
ered when choosing an appropriate location for
equipment installation:
0 Ample space must be allowed to remove
the KSU cover, to access assemblies and
cards within the cabinet and allow space for
the MDF (Main Distribution Frame).
lLocation of...

Page 190

INSTALLATlON
STARPLUS@ SPD 4896Digital Key Telephone System
proper installation can be a serious safety haz-
ard.Failure to provide the proper lightning protec-
tion will increase maintenance expense and
require more available spare parts.
500.2
INSTALLAnON PLANNING FOR THE
SPD 4696 SYSTEM
Prior planning of the installation will aid in a smooth
cut-over and a satisfied customer. Select a suitable
location for the system. Determine the number of
telephones of each type, and the number of Key
Telephone...
Start reading Vodavi Starplus Spd 4896 Hybrid Key Telephone System Installation Manual