Page 71
STARPLUS @ AVP TECHNICAL MANUALINSTALLATION SECTION 500 INSTALLATION500.1 INTRODUCTIONNew Starplus AVP systems come with the liardware pre-config-ured and all software pre-loaded onto the hard drive. All that is re- quired is to connect the monitor, software controller, and the keyboard. These are all external connections and do not require the unit to be disassembled. Once these external connections are made you can power the system up and begin to configure it. The Starplus AVP software contains...
Page 72
INSTALLATIONSTARPLUS @ AVP TECHNICAL MANUAL 500.2 SITESelection of a suitable location is the most basic, yet most critical REQUIREMENTSconsideration in the installation of the Starplus AVP system. The following factors should be considered when choosing an appro- priate location for equipment .installation: lAmple space must be allowed to remove the cabinet cover, to access assemblies and cards within the cabinet and allow space for connections to the unit. There must be room to insert floppy disks...
Page 73
STARPLUS @ AVP TECHNICAL MANUALINSTALLATION overhead lines. Install a transient AC protection device if the system is installed in a manufacturing area where mo- tor driven machinery and such is installed. lProtect the equipment against accumulated static electric- ity which can damage’sensitive electronic circuitry in the enclosure. If the site is at a high altitude or in a dry climate, humidifying the area may be necessary to correct static electricity problems. 500.3 NEW SYSTEM HARDWARE INSTALLATION...
Page 74
INSTALLATIONSTARPLUS @ AVP TECHNICAL MANUAL B. INSTALLING THE SOFIWARECONTROLLERThe controller resembles a standard male/female parallel connec-tor and simply plugs into the parallel port on the back of the PC. If you have a parallel printer or other device attached to that port, temporarily remove it, install the controller, and then reinstall the device on the back of the controller. IMPORTANT! The software controller is designed to recognize the type and version number of the moduks cukently...
Page 75
STARPLUS @ AVP TECHNICAL MANUALINSTALLATION If you have RJ-14 terminations for your phone lines then you need a pair of standard 4-wire modular cables. 2.Connect the modular connectors to any of the jacks on the board. The cable should slide in easily and snap in place when the connection is made. AUDIO Board(s) Up to 34 Port Voice Board 2 Port Voice Board ~Pot-ts 1 & 2Upper modular connector -1P0r-t~ 3 & 4 Lower modular connector Uses RJ14 type wiring Black/Yellow Port 2 Green/Red Port 1Black/Yellow...
Page 76
INSTALLATIONSTARPLUS @ AVP TECHNICAL MANUAL 500.4 NEW SYSTEM SOFTWARE INSTALLATION A. INITIAL SET UPOnce the hardware items are‘installed, you are ready to power the system up and configure the basic items needed for integration. 1.Push the power switch on the front of the enclosure to the ON (depressed) position. The system should go through its power up procedure and load the system software. You should be tit the main screen showing the lines and current status window. 2.Write down the serial number...
Page 77
STARPLUS @ AVP TECHNICAL MANUAL INSTALLATION A listing of the Starplus phone systems that may be loaded will ap- pear. These items are lettered G-K to represent the various Star-plus phone systems that integrate with the Starplus AVP. 5.Enter the letter (G-K) that represents the phone system set- tings you wish to load. 6.Press any key if you are sure this is the phone system you wish to load. Press [CTRL-C] to abort the operation. Once the settings are loaded you will be returned to the utility...
Page 78
.sTAF&lJS @ AVP TECHNICAL MANUAL The system will load the maintenance program and prompt you for a password. ilAINT ~525100v+3.10aConfigurationIlodulesReportsUtilitiesHouseKeepingII IIi ._ mm_. a-lEsc: back a menuR&urn: se1+stl : moves barBackSpace: edits 1.Press the [ENTER] key. This is the default password. The highlight bar should appear on the configuration menu item. 2.Press the [DOWN ARROW] or [ENTER] key to pull down the menu. 3.Highlight the Environment item and press [ENTER]. 4.Highlight the...
Page 79
6.Press the [ESC] key twice. 7.Highlight the Registration item and press [ENTER]. 8.Highlight the Edit Registration item and press [ENTER]. 9. Complete the registration form. You may use the arrow keys, backspace, and enter keys to edit the registration-form. VAINT sn525100 ConfigurationnodulesReportsUtilitiesv+3.10aHouseKeepingI Company :street : City : state : Zip : Phone : Number of Lines : Number of Ext. : PBX nanufacturer : PBX Node1 #Bought SPAVP from: Publications read : Press ESC when done. I-, ....
Page 80
INSTALLATIONSTARPLUS @ AVP TECHNICAL MANUAL COS SE-ITINGS00 - (LEVEL 1) User type 1, max message length 300 seconds, max message count 100, max retention 30 days, use message waiting lamps, lists personal. 01 - (LEVEL 2) User type 1, max message length 300 seconds, max message count 100, max retention 30 days, ignore message waiting lamps, lists personal. 02 - (LEVEL 3) User type 2, max message length 180 seconds, max message count 50, max retention 15 days, use message waiting lamps, lists...