Page 241

iqjinite DVX’ and DVXn 
D&i&d Key Telephone Systemfi 
INSTALLATION 
Refer to Station Attributes Programming. 
730.2. Station ldentifkatlon for programming 
the Station ID of the Digital Data Interface Unit 
(DDIU). Also refer to Sec. 730.3. Digital Data 
Intmface Unit IDDILl) for programming the pa- 
rameters of the Digital Data Interkce Unit 
(DDIUI.  

Page 242

INGTAW*ATfON 
iqjinite DVX’ and DVX II 
Di@al Key Telephone systems 
Table 500-12 SMDR printout 
. 
The SMDR feature provides detailed records of alI outgotng and/or incoming. long distance only 
or all &IS. The SMDR Qualifkation Timer determines the length of time that is needed to 
determine a valid SMDR call for reporting purposes. By default. this timer is set to 30 seconds 
and is variable from 00 to 60 seconds in I sec. increments. This feature is enabled or disabled in 
system programming. By...

Page 243

imite DVX’ and DVX” 
Table 500-13 ShfDR printout [C-ont’d) 
AAA = Station 
originator or Trunk on DISA and Off-Net (CO Line) calls. 
BB = Outside line number 
HH:MM:SS = Duration of call in Hours, Minutes and Seconds 
HH:MM = Time of day (start time) in Hours and Minutes 
MM/DD/YY = Date 
of Call 
H = Indicates call type: 
“I” = Incomi.ng 
“0” = outgoing 
T=Transfcrred 
‘7J” = Unanswered c&Us for ICIJD SMDR call records 
CC....CC = Number dialed 
GG....GG = Last Acmxmt code entered (optional] 
(CR) =...

Page 244

i@nite DVX ’ and DVX ’ 
DigiW Key Telephone Sy8tezns 
spsTEh¶ CBECE-OUT 
SECTION 600 
SYSTEM CHECK-OUT 
600.1 INTRODUCTION 
prior to actual power up and initialization. the 
infinite Digital Key Telephone System should be 
checked over to avoid start up delays or im- 
proper loading. A step-by-step checklist is pro- 
vided for this purpose. 
6cKI.2 
PREW PROCEDURES 
f . Make sure that the Basic Key service Unit 
(BKSU) is properly grounded. 
2. Verify that all PCB’s are firmly plugged into 
the correct...

Page 245

r 1 
i&hite DVX’ and DVX’ 
D&it& Key Telephone Systems CUSTOMER DATA BASE PROGR&MlkDNG 
SECTION 700 
CUSTOMER DATA BASE PRUG-NG 
700.1 INTRODUCTION 
The infinite Digital Key Telephone System can 
be programmed to meet each customer’s indi- 
vidual needs. All programming is done either at 
Station I00 using the 33-button display digital 
terminal as the programming instrument or an 
ASCII texminal or PC. The distal display model 
is suggested since the display is designed to 
assist in programming. 
When...

Page 246

CDSTOMER DATA RASE PROGRAbI&mVG ir@ite DVX’ and DVX’ 
Di@taI Key Telephone Systems 
When using a data terminal 0/O device) to program the system. the following chart presents the data 
terminal characters that are equivalent to the keyset buttons. 
adm> ? 
REl-tOTE ADtlIN KEY DEFINITIONS 
Keyset Term Keyset 
Term Keyset 
Term 
---------I------------------------------- 
0 0 
FLEX i FLEX 11 FI 
1 
3 : FLEX 2 ; 
FLEX 12 S 
z FLEX  FLEX 3  4 E  R FLEX  FLEX 13  14 F D 
2 5” FLEX  FLEX 6  5 Y T FLEX  FLEX 16...

Page 247

irlfirtf& DVX’mdDVX’I 
Dj#ital Key Telephone Systems 
CUSTOMER DATA BASE PROGRAMMING 
If&urr: ?oQ-2 InfidteDigitaIRogramming Button Mapping  

Page 248

CUSTOMER DATA aASE mOGFG il?jidte DVX’andDVX” 
Digital Key Telephone Systems 
Table 700-I Defatit 
Value5 
i SYSTEM T’IMERS: 
1 
System Hold Recall Timer 
Exclusive Hold RecaIl Timer 
Attendant Recall Timer 
Transfer Recall Timer 
Preset Forward Timer 
Call Forward No/Answer Timer 
Pause Timer 
Call Park Timer 
Confere.nce/DISA Timer 
Paging Tlimeout TJmer 
CO Ring DetectTimer 
SLT D’I’MF Receiver Timer 
MSG Waiting Reminder Tone 
Hookflash Tfmer 
Hookflash Debounce Tfmer 
SMDR Call QuaLiftcaton Timer...

Page 249

i@inite DVX’andDVX’ 
D&&d Eey Telephone SyMcrn8 CUSTQMER DATA BASE PROGFMMBUING 
Table 700- 1 Default Values (Cant’d) 
When the ACD Software package is purchased 
listed ACD 
features. 
FEATURE 
/ Port #3 Q/O Expander 
Module RS-232C) 
Port #4 [I/O 
Expander Module R!H22) 
Acces& Codes 
DISA Access 
Code 
Acimin password for Digital Key Tw 
Sh4DR PROGRAMMlNG 
SMDR 
Cd?srpe 
Print Format 
Baud Rate 
Polt# 
MGHl. 
MODE PROGRAMMING: 
Auto/Manual 
Days of the Week !Schedule 
Directory Dw Table 
Bin/KM 
Name...

Page 250

CUSTOMER DATA IBASE PROGRAMMING iqjinite DvX’aadDVX” 
DIgital Key Telephone Systems 
Table 700-l Default Values (Cont’d] 
1 Display Ring Assigumentb) 
; Next [forward) CO 
j Next (backward) CO 
; NewRange 
Dial Puke, 
Speed/Ratio programming 
Break/Make 
Dial speed 
Fkxible PortAssignment Feature - CO Lines 
ICLID Ringing Assignment Feature 
STAnON PROGRAMMING: 
Page Access 
DND Access 
Conference 
Executive Override 
pnivacy 
System Speed 
0ueuing 
Preferred Line Answer 
OWO 
Call Forward 
Forced LCR...