General Information
RT-SVX24K-EN21
prevent over/under pressurization. The overall scheme
will remain very similar to VAV units with Space Pressure
Control with the exception of the dynamic Exhaust Enable
Setpoint.
For SZVAV an Exhaust Enable Setpoint must be selected
during the 100% Fan Speed Command. Once selected, the
difference between the Exhaust Enable Setpoint and
Design OA Damper Minimum Position at 100% Fan Speed
Command will be calculated.The difference calculated will
be used as an offset and...

Page 22

General Information
22RT-SVX24K-EN
The damper is commanded to a position based on a 2-10
VDC signal. If the Damper position is outside of ±10% of the commanded position, a diagnostic is generated.
Unit Not Economizing when it should be:
The Unit is operating in Cooling Mode, Economizing is enabled and/or Mechanical Cooling is enabled. If the
Commanded Economizer Position is greater than Current
Economizer Feedback Position + 10% for 5 continuous
minutes, Unit Not Economizing when it should be
diagnostic...

Page 23

RT-SVX24K-EN23
Unit Clearances
Figure 10. Minimum required clearance(a)
(a) Unit drawing is representative only and may not accurately depict all mo\
dels.
Filters
VFDVFDHeat
Rtn/Exh
MtrRtn/Exh
VFDEvp(F)Fltr(F)SupMtrSup
VFD
Fltr(R)Evp(R)
Heat(L&R
Option
Option
As Req. As Req. As Req.
Std
Std Std
Std
Blank Section
Final 
Filter
Fnl
Fltr 
As Req.
Fnl
Fltr  As Req.
Ctrl Box(L&R)Std
OutsideAir
OutsideAir
  Exhaust
Condenser
Condenser
Exh
AH  R
CBox
AH  LCond L
Cond R
Left Side
Table 4. Minimum required...

Page 24

Unit Clearances
24RT-SVX24K-EN
Notes:
 1. Stagger units to minimize span deflection which deters sound 
transmission and to maximize proper diffusion of the exhaust air 
before it reaches the adjacent unit outside air intake.
 2. Cooling tower should be 5 feet above or 20 feet away from the outside 
air intake. For additional information, see 2007 ASHRAE Handbook: 
HVAC Applications, page 44.4.
Figure 11. Multiple unit placement
Outdoor
Air Intake
Outdoor
Air Intake
Exhaust Air 
Outdoor
Air Intake...

Page 25

RT-SVX24K-EN25
Dimensional Data
Figure 12. Unit Top/Front View
1-1/4 NPT. DRAIN
2X TYP. LEFT & RIGHT SIDES OF UNIT
Detail A 

Page 26

Dimensional Data
26RT-SVX24K-EN
Table 5. Unit dimensions (in.)—one-piece unit air-cooled
ONE-PIECE Dimensions without Energy Recovery Wheel (ERW)
Tonnage  Blank 
Section Unit Dimensions Lifting Lug Locations
Unit Width
Air Handler Side Condenser 
Side
A B C1 C2 C3 D1 M N
90  None 437  3/16 159 15/16 66       252 14/16 N/A 27 11/16 139 13/16 143  8/16
90  4 ft 485  6/16 159 15/16 66       252 14/16 N/A 54  2/16 139 13/16 143  8/16
90 8 ft 533  9/16 159 15/16 66       252 14/16 N/A 54  2/16 139 13/16 143...

Page 27

Dimensional Data
RT-SVX24K-EN27
Table 6. Unit dimensions (In.)—two-piece unit air-cooled
 TWO-PIECE Dimensions without Energy Recovery Wheel (ERW)
Tonnage  Blank 
Section Unit Dimensions Lifting Lug Locations
Air Handler Side
A B E F C1 C2 C3 C4
90  None 454  4/16 159 15/16 330 14/16 121  6/16 66       252 14/16 N/A N/A
90  4 ft 502  7/16 159 15/16 379  1/16 121  6/16 66       252 14/16 368  6/16 N/A
90 8 ft 550 11/16 159 15/16 427  4/16 121  6/16 66       252 14/16 416 10/16 N/A
105 None 472  4/16 159...

Page 28

Dimensional Data
28RT-SVX24K-EN
Tonnage Blank 
Section Return Fan Exhaust Fan
JK
90  None 29  3/16 17
90  4 ft 29  3/16 17
90 8 ft 29  3/16 17
105 None 29  3/16 17
105 4 ft 29  3/16 17
105 8 ft 29  3/16 17
120-150 
(All Units 
Except High  Heat Gas Models)  None 29  3/16
17
120-150 
(All Units 
Except High  Heat Gas Models)  4 ft 29  3/16
17
120-150 
(All Units 
Except High  Heat Gas Models)  8 ft 29  3/16
17
120-150 
(High Heat 
Gas Models  Only) None 29  3/16
17
 TWO-PIECE Dimensions with Energy...

Page 29

Dimensional Data
RT-SVX24K-EN29
Tonnage Blank 
Section Lug Locations
Unit Width
Condenser Side Unit Height
D1 D2 M N O P R
90  None 16       112  7/16 139 13/16 143  8/16 103 12/16 97  9/16 103  7/16
90  4 ft 16       112  7/16 139 13/16 143  8/16 103 12/16 97  9/16 103  7/16
90 8 ft 16       112  7/16 139 13/16 143  8/16 103 12/16 97  9/16 103  7/16
105 None 16       130  7/16 139 13/16 143  8/16 103 12/16 97  9/16 103  7/16
105 4 ft 16       130  7/16 139 13/16 143  8/16 103 12/16 97  9/16 103  7/16...

Page 30

Dimensional Data
30RT-SVX24K-EN
Table 7. Unit dimensions (in.)—two-piece unit evaporative condenser
 TWO-PIECE Dimensions without Energy Recovery Wheel (ERW)
Tonnage  Blank 
Section Unit Dimensions Lifting Lug Locations
Air Handler Side
A B E F C1 C2 C3 C4
100-118  None 475  8/16 159 15/16 330 14/16 142 10/16 66       252 14/16 N/A N/A
100-118  4 ft 523 12/16 159 15/16 379  1/16 142 10/16 66       252 14/16 368  6/16 N/A
100-118  8 ft 571 15/16 159 15/16 427  5/16 142 10/16 66       252 14/16 416 10/16...
Start reading Trane Intellipak 2 Service Manual

Related Manuals for Trane Intellipak 2 Service Manual

All Trane manuals