Toshiba Estudio 230 Manual
Here you can view all the pages of manual Toshiba Estudio 230 Manual. The Toshiba manuals for Printer are available online for free. You can easily download all the documents as PDF.
Page 651
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 POWER SUPPLY UNIT 7 - 1 7 7. POWER SUPPLY UNIT 7.1 Output Channel The followings are five output channels which are n ot linked with the door switch. 1) +3.3V +3.3VA : CN705 Pins 13, 14, 15 and 16 Output to the SYS board +3.3VB : CN705 Pins 19 and 20 Output to the SYS board +3.3VB : CN706 Pin 30 Output to the LGC board +3.3VB : CN708 Pins 9 and 10 Output to the SLG board 2) +5.1V +5.1VA : CN705 Pins 24 and 26 Output to the SYS board +5.1VB : CN705...
Page 652
e-STUDIO200L/202L/230/232/280/282 POWER SUPPLY UNITJune 2004 © TOSHIBA TEC 7 - 2 The followings are two output channels which are li nked with the door switch. 1) +5.1V +5.1VD : CN706 Pin 2 Output to the LGC board 2) +24V +24VD1 : CN706 Pins 11, 12, 13 and 14 Output to the LGC board, PFP/LCF (via LGC board) +24VD1 : CN707 Pins 15 and 16 Output to the main motor +24VD2 : CN706 Pins 5 and 6 Output to the LGC board, High-voltage transformer ( via LGC board), Bridge unit / Job separator / Offset tray (via...
Page 653
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 POWER SUPPLY UNIT 7 - 3 7 7.2 Fuse When the power supply secondary fuse is blown out, confirm that there is no abnormality with each part using the following table. Voltage Board/Unit Part Fuse type +24VD1 LGC Main motor F4:8A (Semi time-lag) Toner motor Polygonal motor Tray-up motor Internal cooling fan 1 Internal cooling fan 2 Auto-toner sensor Upper drawer feed clutch Lower drawer feed clutch Registration roller clutch Upper transport clutch...
Page 654
e-STUDIO200L/202L/230/232/280/282 POWER SUPPLY UNITJune 2004 © TOSHIBA TEC 7 - 4 7.3 Configuration of Power Supply Unit Fig.7-1 PWR-DN PWR-EN +3.3VA +3.3VB +3.3VB +3.3VB +5.1VA +5.1VB +5.1VBCN705 CN705 CN706 CN708 CN705 CN705 CN706 +5.1VB CN707 SYS board SYS board SYS board, LGC board SYS board LGC board SLG board SYS board SYS board SLG board, RADF +5.1VB CN708Finisher +12VA CN705 SYS board SYS board SYS board LGC board SLG board SYS board -12VA CN705 +12VB CN705 +12VB CN706 +12VB CN708...
Page 655
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 REMOTE SERVICE 8 - 1 8 8. REMOTE SERVICE There are following functions as Remote Service. 1) Auto Supply Order Automatically orders the toner by FAX or E-mail. 2) Service Notification Notifies the status of the equipment to the service technician by E-mail or FAX. 8.1 Auto Supply Order 8.1.1 Outline Automatically orders the toner. 1) Placing an Order There are two ways to place an order. - FAXInstallation of the FAX board is required. If the...
Page 656
e-STUDIO200L/202L/230/232/280/282 REMOTE SERVICEJune 2004 © TOSHIBA TEC 8 - 2 8.1.2 Setting Item To enable Auto Supply Order, the following settings are required. Note: Note: When selecting E-mail to place an order, it is requ ired that sending and receiving E-mails are available. Confirm the details to the administrator . 1) Self-diagnosis (08) Setting As the default setting, the Auto Supply Order setti ng screen is not displayed on the touch panel. To display it, switching the Valid/Invalid setting...
Page 657
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 REMOTE SERVICE 8 - 3 8 2) Touch Panel Setting Each item is set from the Auto Supply Order screen on the touch panel. Entering the password and customer information is r equired because the setting is made from the ADMIN screen. Setting it with the administrator is a must. - Basic setting [ADMIN] > [SERVICE] > [SUPPLY ORDER SETUP] > [ORDER INFORMATION] *1 HTTP has not been supported yet. *2 Even when “FAX” is selected, the order is not pl aced...
Page 658
e-STUDIO200L/202L/230/232/280/282 REMOTE SERVICEJune 2004 © TOSHIBA TEC 8 - 4 - Detailed setting for the order [ADMIN] > [SERVICE] > [SUPPLY ORDER SETUP] > [TONER ORDERING] *1 The order is placed when the number of replaceme nt reaches the number specified for the CONDITION. - FAX number of this equipment (common information) [ADMIN] > [FAX] > [TERMINAL ID] - E-mail information of this equipment (common inform ation) [ADMIN] > [E-MAIL] *1 When sending an E-mail, validity of the address is checked. If...
Page 659
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 REMOTE SERVICE 8 - 5 8 8.1.3 Setting procedure (1) Start up the self-diagnosis setting mode 08-765, and then change the setting value to “0”. (2) Turn the power OFF, and then ON. (3) Press the [USER FUNCTIONS] button to enter the user function screen. (4) Press the [ADMIN] button. When the Administrator Password has been set, ADMI NISTRATOR PASSWORD screen is displayed. Fig.8-1 (5) Press the [PASSWORD] button and the screen is sw itched to a...
Page 660
e-STUDIO200L/202L/230/232/280/282 REMOTE SERVICEJune 2004 © TOSHIBA TEC 8 - 6 (7) The SERVICE screen is displayed. Fig.8-3 (8) Press the [SUPPLY ORDER SETUP] button. Fig.8-4 (9) Press the [ORDER INFORMATION] button. (10) The ORDER INFORMATION screen is displayed. Fig.8-5