June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
6 - 67
6
Important:   The following USB storage devices are recommended  for updating.
- MELCO ClipDrive (RUF-C128M) 
- Lexar Media JumpDrive (RD128-231) 
- Iomega Mini USB Drive (Mini 128 MB USB Drive)
 Only the USB storage device which meets the follow ing conditions should be used for updat-
ing. Be careful since updating with any device othe r than the above is never guaranteed.
- A combination USB storage device with a...

Page 622

e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
6 - 68
(3) Connect the USB storage device to the USB connec tor (host) on the SYS board.
 Fig.6-71
Notes: 
 Do not connect multiple USB storage devices togeth er.
 The USB storage device can be connected to either  of 2 USB connectors (host).
 In case the printer kit (GM-1020 or 1030), printer /scanner kit (GM-2020 or 2030) and scanner 
upgrade kit (GM-3020 or 3030) are used, the update  must be performed after all the don-...

Page 623

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
6 - 69
6
(4) Turn ON the power while [4] button and [9] butto n are pressed simultaneously.
The screen for selecting the items to be updated is  displayed after 3 minutes. “*” is displayed 
next to the items to be updated. (All items other t han 0. OS Update are selected in the default 
settings.)
 Fig.6-72
Note: Note:  The display of items on this screen varies dependin g on the types of data written on the USB 
storage device....

Page 624

e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
6 - 70
(5) Select the item with the digital keys. “*” is displayed next to the selected item. Display  or delete the “*” by pressing the number of the 
item. All items are selected in the default setting s.
 Select all items to update the firmware of the equ ipment in a batch.
 Select items as follows to update individually.
Select 0. OS Update only.
 Select “1. HDD Update” only.
 Select “2. UI Data Update” and “3. System...

Page 625

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
6 - 71
6
(6) Press the [START] button. Updating starts and the processing status is display ed on the LCD screen. When the multiple 
items are selected, updating starts in order of ite m number.
 Fig.6-75
(7) “Update Completed.” is displayed at the bottom o f the LCD screen after the updating is com-
pleted properly.
 Fig.6-76 

Page 626

e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
6 - 72
Remark:  Updating can be continued with another USB storage  device on which the firmware data is writ-
ten in the following procedure when the updating is  completed.
1. Confirm the message “Please Connect Next Storage  Key. Push ‘START’ Button!!” is dis-
played at the bottom of the LCD screen.
2. Replace the USB storage device while the power is  left ON.
3. Press the [START] button. 
4. The screen for selecting the items...

Page 627

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
6 - 73
6
*When the updating of the NIC firmware is failed, a n error message is displayed as the figure 
below. Turn OFF the power and then check the above- mentioned items. After confirming 
them, select only “4. NIC Firmware Update” and rest art updating from the beginning. This 
may complete the updating properly.
 Fig.6-78
If the updating of the NIC firmware is still failed , check the prescription corresponding to the error...

Page 628

e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
6 - 74
(8) Turn OFF the power, remove the USB storage devic e.
(9) Perform the initialization of the updating data  (NVRAM updating).
 Turn ON the power while [0] button and [8] button  are pressed simultaneously.
 Key in “947”, and then press the [START] button. 
 Press the [INITIALIZE] button.
[B] Confirmation of the updated data 
After the updating is completed, check each data ve rsion in the Setting Mode (08) to confirm...

Page 629

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
6 - 75
6
[C] Display during the update 
The processing status is displayed as follows on th e LCD screen during the update. (As an example, 
the display for updating the system ROM is explaine d below.)
When the device is recognized properly after 3  
minutes, the screen for selecting items is dis- 
played. 
Press the [START] button after selecting the  
item to be updated. The device check starts. 

Page 630

e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
6 - 76
When the device check completes, copying the  
data to the HDD starts. 
When all files have been copied, the backup of  
RIP font starts. 
When the backup of RIP font is completed, the  
following screen is displayed. Updating the mas- 
ter data is completed. 