Page 601

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
6 - 47
6

(1) Install the ROM to the download jig. Make sure the direction is correct (P.6-32 Fig.6-3 5).
(2) Turn OFF the power of the equipment. 
(3) Take off the right upper cover-1.
 Fig.6-44
(4) Take off the right upper cover-2.
 Fig.6-45
Right upper cover-1
Right upper cover-2
05/11 

Page 602

e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
6 - 48
(5) Remove the cover plate.
 Fig.6-46
(6) Connect the download jig with the jig connector  (CN22) on the scanning section control PC 
board (SLG board).
 Fig.6-47
(7) Turn ON the power while [0] button and [8] butto n are pressed simultaneously.
Updating starts automatically and the LED on the dow nload jig lights.
(8) After the update is completed properly, the LED  on the download jig blinks. The LED starts blink-
ing in...

Page 603

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
6 - 49
6

(1) Install the ROM to the download jig. Make sure the direction is correct (P.6-32 Fig.6-3 5).
(2) Turning OFF the power of the equipment. 
(3) Take off the RADF rear cover. 
(4) Connect the download jig with the connector (CN8 1) on the PC board.
 Fig.6-48
(5) Turn ON the power while [0] button and [8] button are pressed simultaneously.
Updating starts automatically and the LED on the dow nload jig lights.
(6) When the...

Page 604

e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
6 - 50

(1) Install the ROM to the download jig. Make sure the direction is correct (P.6-32 Fig.6-3 5).
(2) Turn OFF the power of the equipment. 
(3) Take off the finisher rear cover.
 Fig.6-49
*Connect the finisher interface cable with the equi pment after removing the finisher rear cover.
(4) Connect the download jig with the jig connector o n the finisher control PC board.
 Fig.6-50
(5) Change the setting of he DIP switch on...

Page 605

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
6 - 51
6
Note: Note:  Record the current settings of the DIP switch befor e changing them. After the updating is com-
pleted, return the DIP switch to the status as reco rd.
 Fig.6-51
(6) Turn ON the power while [0] button and [8] butto n are pressed simultaneously.
Updating starts automatically and the LED on the dow nload jig lights.
(7) After the update is completed properly, the LED  on the download jig blinks slowly. The LED...

Page 606

e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
6 - 52

Important:   Before updating the FAX ROM, make sure to print ou t the current Function list for mainte-
nance, Function list (ADMIN), Phone book number inf ormation and Group number informa-
tion. In case the updating is failed and the regist ered information of the users is lost for some 
reason, re-register the user information referring  to the lists and recover it.
 Confirm the following items before turning OFF the...

Page 607

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
6 - 53
6
(5) Turn ON the power while [0] button and [8] butto n are pressed simultaneously. Updating starts 
automatically and the LED on the download jig light s.
(6) After the update is completed properly, the LED  on the download jig blinks. The LED starts blink-
ing in approx. 30 sec. since the update starts. It i s assumed that the update is failed if it does not 
start blinking even though 1 min. has passed. In th is case,...

Page 608

e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
6 - 54
6.3 Firmware Updating with FSMS (Field Service Manag
er) 
(e-STUDIO200L/230/280)
In this equipment, it is feasible to update the dow nloaded firmware from the PC connected with the 
equipment by using the utility software “FSMS (Fiel d Service Manager)”.
Refer to the Field Service Manager Operator’s Manual  for the details about installation method and 
functions of FSMS.
 Fig.6-54
Important:   Updating through USB is not...

Page 609

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
6 - 55
6
The types of firmware which can be updated with thi s method are as follows in the table below.
Firmware Stored Data file name
Master data Hard disk uidata2.tz, uidata3.tz, uidata4 .tz, uidata5.tz, 
uidata6.tz, uidata7.tz, webdata1.tz,  
webdata2.tz, webdata3.tz, webdata4.tz,  
webdata5.tz, webdata6.tz, all.tz
System ROM System control PC board (SYS board) sysfirm.tz, uidataF.tz, uidata0.tz, uidata1.tz
Engine ROM Logic PC...

Page 610

e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
6 - 56
[A] Update procedure
Important:   Do not operate the equipment or send a print job t o the equipment during the update. This 
interferes the updating operation and the firmware  may not be written properly.
 Do not turn OFF the power of equipment or PC durin g the update. The data could be dam-
aged and not to be continued to function properly.
 When using FSMS, set “1” at FSMS permission code ( 08-258) in the Setting...