Page 561
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 7 6 [B] Confirmation of the updated data After the updating is completed, check each data ve rsion in the Setting Mode (08) to confirm that the data was overwritten properly. 08-900: System ROM version 08-920: FROM basic section software version 08-921: FROM internal program version 08-922: UI data fixed section version 08-923: UI data common section version 08-924: Version of UI data language 1 in HDD 08-925: Version...
Page 562
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 8 [C] Display during the update The processing status is displayed as follows on th e LCD screen during the update. The device check starts. When the device check completes, copying the data to HDD starts.
Page 563
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 9 6 When copying all the files completes, the backup of the RIP font starts. When the backup of the RIP font completes, the update completes with the following screen.
Page 564
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 10 * If an error occurs, the following error message is displayed and the update is interrupted.
Page 565
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 11 6 6.1.2 PWA-DWNLD-350-JIG1 (16 MB) The firmware of the equipment except the hard disk and the option can be updated individually or in a batch by using PWA-DWNLD-350-JIG1 (16 MB). Update t he ROM data written on each board accord- ing to the need such as the case of replacing the sy stem control PC board, logic PC board, scanning section control PC board, or NIC board. The data to be overwritten by this update are as...
Page 566
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 12 (4) Connect the download jig with the jig connector (CN100) on the SYS board. Fig.6-10 (5) Turn ON the power while [8] button and [9] butto n are pressed simultaneously. The screen for selecting the items to be updated is displayed. “*” is displayed next to the items to be updated. (All items are selected in the default settings.) Fig.6-11 Connector
Page 567
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 13 6 (6) Select the item with the digital keys. “*” is displayed next to the selected item. Display or delete the “*” by pressing the number of the item. All items are selected in the default setting s. Select all items to update the firmware of the equ ipment in a batch. Select items as follows to update it individually. Select “1. OS Update”, “2. UI Update”, and “3. Syst em Firmware”. Select “6. Machine Firmware...
Page 568
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 14 (8) “Update Completed!!” is displayed at the bottom of the LCD screen after the updating is com- pleted properly. Fig.6-14 “Update Failed.” is displayed at the bottom of the LCD screen when the updating is not com- pleted properly. Turn OFF the power, and then check the following items. After confirming and clearing the problems, restart updating from the be ginning. Is the download jig connected properly? Is the...
Page 569
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 15 6 *When the updating of the NIC firmware is failed, a n error message is displayed as the figure below. Turn OFF the power and then check the above- mentioned items. After confirming them, select only “4. NIC Firmware Update” and rest art updating from the beginning. This may complete the updating properly. Fig.6-16 If the updating of the NIC firmware is still failed , check the prescription corresponding to the error...
Page 570
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 16 (9) Turn OFF the power, remove the download jig and install the cover plate. (10) Perform the initialization of the updating data (NVRAM updating). Turn ON the power while [0] button and [8] button are pressed simultaneously. Key in “947”, and then press the [START] button. Press the [INITIALIZE] button. [B] Confirmation of the updated data After the updating is completed, check each data ve rsion in the Setting...