Page 351

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 55
3
(7) Tighten the positioning pin at the front side. Close the RADF to fit the positioning pin into  
the hole at the front side of the RADF. (For 
the front side, adjust the RADF position all  
around.)
 Fig.3-56
(8) While peering inside from the left side, close the RADF. Check the positions of the holes  
of the RADF and pins and then fit their posi- 
tions by moving the RADF back and forth.  
(For the front side, also adjust...

Page 352

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 56
(10) Match the rear hole of the right-hand hinge  and the hole of the equipment side to tighten  
the stepped screw. If they do not fit, adjust 
the position of the hole by turning the screw  
of the adjustment plate.
 Fig.3-59
(11) Tighten the stepped screw and 2 screws on the adjustment plate. 
Open and close the RADF to check again  
that the positioning pins fit smoothly into the  
holes on the RADF. Remove the positioning...

Page 353

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 57
3
3.10.2 Adjustment of RADF height
It is mainly performed at the installation. It is a lso required when the RADF is dislocated for some re a-
son such as moving the equipment. 
Perform the following adjustment by using the screw o f the left and right hinge.
Note: Note: 
Perform this adjustment after “3.10.1 Adjustment of  RADF position”.
Turn the exposure lamp ON during the gap check. (Te st Mode: 03-267)

(1) Adjustment...

Page 354

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 58
(3) Adjust the height by turning the height  adjusting screw on the left hinge. 
CW: The height of the hinge becomes high.
CCW: The height of the hinge becomes low.
 Fig.3-64 

Page 355

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 59
3
3.10.3 Adjustment of skew
When an image skew occurs, adjust it according to th e following steps, Step 1  Step 2   Step 3.
Note: Note: 
Perform this adjustment after confirming that the e quipment has been adjusted properly.
Prior to this adjustment, of RADF position and heig ht are needed to be adjusted.
(1) Step 1 
Case A:  
Adjust the aligning adjustment position to the rear  side “-” of the original ( P.3-62 3.10.5...

Page 356

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 60
(2) Step 2 
Case C: 
Loosen the fixing screw and hand screw of the right  side hinge and then turn the adjustment 
screw counterclockwise.
Case D: 
Loosen the fixing screw and hand screw of the right  side hinge and then turn the adjustment 
screw clockwise.
Note: Note:  When adjusting, refer to the hinge position (scribe d line) and be sure not to move it from the 
hinge position ±0.5 mm or further. Otherwise, image  failures...

Page 357

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 61
3
3.10.4 Automatic adjustment of sensors and initializ ation of EEPROM
When any of the PC board, original length sensor, read sensor, reverse sensor is replaced with a new 
one, make sure to perform the initialization of EEP ROM and adjustment of sensors in the Adjustment 
Mode (05). 
Perform them after removing all originals on the se nsor and closing the RADF.
Also, make sure to adjust the tray volume when the  initialization of...

Page 358

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 62
3.10.5 Adjustment of aligning
Adjust the aligning according to Step 1 of 3.10.3.
 Fig.3-69
-  Rear side - of the original
Skew of paper
Rear side + of the original  + 

Page 359

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 63
3
3.10.6 Adjustment of aligning at reversing
Adjust the aligning according to Step 3 of 3.10.3.
 Fig.3-70
Screw of pape r 

Page 360

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 64
3.10.7 Adjustment of reverse solenoid
When operating the reverse solenoid, adjust it if t
he position of the flapper lever is out of the following 
dimension. 
Gap between A of the front frame and the flapper le ver “C”: 0.5 mm to 2.0 mm

(1) Remove the screw on the left and take off the  plate spring.
 Fig.3-71
(2) Align B of the front frame with the edge of the  reverse solenoid, and temporarily fix the  
reverse solenoid with...
Start reading Toshiba Estudio 230 Manual