Home > Toshiba > Printer > Toshiba Estudio 230 Manual

Toshiba Estudio 230 Manual

Here you can view all the pages of manual Toshiba Estudio 230 Manual. The Toshiba manuals for Printer are available online for free. You can easily download all the documents as PDF.

Page 361

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 65
3
(4) Fix the plate spring temporarily with the  screw on the left. Then press the plate spring  
slightly in the direction of an arrow and 
tighten the screw in the position where the  
gap (D) between the plunger and the flapper  
lever is eliminated.
 Fig.3-74
DD
Flapper leverPlunger 

Page 362

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 66
3.10.8 Adjustment of RADF opening/closing switch
Adjust the bracket position so that the switch is t
urned ON when the height A becomes 40-45 mm 
(within the empty weight falling limit).
 Fig.3-75
Glass surface
A
Center 

Page 363

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 67
3
3.10.9 Adjustment of RADF opening/closing sensor
Adjust the bracket position so that the sensor is t urned ON when the height A becomes 30-35 mm 
(within the empty weight falling limit).
 Fig.3-76
Glass surface
A
Center 

Page 364

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 68
3.10.10 Adjustment of tray volume

(1) While pressing [0] and [5] simultaneously,  turn the power ON.
(2) Narrow the original guide to the limit. 
(3) Input the code 367. 
(4) Press the [START] button.
 Fig.3-77
(5) Extend the original guide to the limit. 
(6) Input the code 368. 
(7) Press the [START] button 
(8) Turn the power OFF.
 Fig.3-78 

Page 365

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 69
3
3.11 Adjustment of the RADF (MR-3020) 
3.11.1 Adjustment of RADF Position
Perform this adjustment when the RADF is not instal led in the correct position.
Note: Note: 
Check if the image adjustment for the equipment is p erformed properly before this adjustment of 
the RADF.
[A] Checking
(1) Open the RADF and install 2 positioning pins  (the positioning pins are installed to the back  
side of the hinge which is on the left side...

Page 366

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 70
[B] Adjustment 
If the pins cannot be fitted into the holes, perfor m the adjustment according to the following procedu re.
(3) Close the RADF and check if the positioning 
pins fit the holes on the RADF.
 Fig.3-81
(1) Remove the right-hand hinge screw at the 
rear side.
 Fig.3-82
(2) Loosen the left-hand hinge screw at the rear side.
 Fig.3-83
05/11 

Page 367

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 71
3
(3) Loosen the hinge screws at the front side.
 Fig.3-84
(4) Position the pins with the holes on the RADF  by moving it so that the pins fit into the holes  
when the RADF is closed.
 Fig.3-85
(5) Tighten the left-hand hinge screw at the rear 
side.
 Fig.3-86
05/11 

Page 368

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 72
(6) Loosen the hole position adjustment screws  on the right hand side.
 Fig.3-87
(7) Match the screw hole positions.
 Fig.3-88
(8) Install the right-hand hinge screw at the rear 
side.
 Fig.3-89
05/11 

Page 369

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 73
3
(9) Loosen the hinge screws at the front side.
 Fig.3-90
(10) Place the platen sheet on the original glass  and align it to the top left corner. 
Close the RADF gently and open it to check  
if the platen sheet is attached properly.
 Fig.3-91
05/11 

Page 370

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 74
3.11.2 Adjustment of RADF Height
Note: Note: 
Check if the image adjustment for the equipment is p erformed properly before this adjustment of 
the RADF.
[A] Checking
(1) Close the RADF. 
(2) Light the exposure lamp.  Turn the power ON while pressing [0] and [3] simul taneously.
 Key in [267] and then press the [START] button. Th e exposure lamp is turned ON for a given 
length of time.
(3)  Visually check the gap between platen...