Page 361
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 65 3 (4) Fix the plate spring temporarily with the screw on the left. Then press the plate spring slightly in the direction of an arrow and tighten the screw in the position where the gap (D) between the plunger and the flapper lever is eliminated. Fig.3-74 DD Flapper leverPlunger
Page 362
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 66 3.10.8 Adjustment of RADF opening/closing switch Adjust the bracket position so that the switch is t urned ON when the height A becomes 40-45 mm (within the empty weight falling limit). Fig.3-75 Glass surface A Center
Page 363
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 67 3 3.10.9 Adjustment of RADF opening/closing sensor Adjust the bracket position so that the sensor is t urned ON when the height A becomes 30-35 mm (within the empty weight falling limit). Fig.3-76 Glass surface A Center
Page 364
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 68 3.10.10 Adjustment of tray volume (1) While pressing [0] and [5] simultaneously, turn the power ON. (2) Narrow the original guide to the limit. (3) Input the code 367. (4) Press the [START] button. Fig.3-77 (5) Extend the original guide to the limit. (6) Input the code 368. (7) Press the [START] button (8) Turn the power OFF. Fig.3-78
Page 365
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 69 3 3.11 Adjustment of the RADF (MR-3020) 3.11.1 Adjustment of RADF Position Perform this adjustment when the RADF is not instal led in the correct position. Note: Note: Check if the image adjustment for the equipment is p erformed properly before this adjustment of the RADF. [A] Checking (1) Open the RADF and install 2 positioning pins (the positioning pins are installed to the back side of the hinge which is on the left side...
Page 366
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 70 [B] Adjustment If the pins cannot be fitted into the holes, perfor m the adjustment according to the following procedu re. (3) Close the RADF and check if the positioning pins fit the holes on the RADF. Fig.3-81 (1) Remove the right-hand hinge screw at the rear side. Fig.3-82 (2) Loosen the left-hand hinge screw at the rear side. Fig.3-83 05/11
Page 367
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 71 3 (3) Loosen the hinge screws at the front side. Fig.3-84 (4) Position the pins with the holes on the RADF by moving it so that the pins fit into the holes when the RADF is closed. Fig.3-85 (5) Tighten the left-hand hinge screw at the rear side. Fig.3-86 05/11
Page 368
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 72 (6) Loosen the hole position adjustment screws on the right hand side. Fig.3-87 (7) Match the screw hole positions. Fig.3-88 (8) Install the right-hand hinge screw at the rear side. Fig.3-89 05/11
Page 369
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 73 3 (9) Loosen the hinge screws at the front side. Fig.3-90 (10) Place the platen sheet on the original glass and align it to the top left corner. Close the RADF gently and open it to check if the platen sheet is attached properly. Fig.3-91 05/11
Page 370
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 74 3.11.2 Adjustment of RADF Height Note: Note: Check if the image adjustment for the equipment is p erformed properly before this adjustment of the RADF. [A] Checking (1) Close the RADF. (2) Light the exposure lamp. Turn the power ON while pressing [0] and [3] simul taneously. Key in [267] and then press the [START] button. Th e exposure lamp is turned ON for a given length of time. (3) Visually check the gap between platen...