Page 311
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 15 3 [C] Image position adjustment of the primary scannin g direction (1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode) (2) Place a ruler on the original glass with its lea ding edge pushed against the rear side and its side along the original scale on the left. (3) Press [FAX] to make a copy at the mode of A3 (LD ), 100% and standard drawer of the equipment (Refer to *). *Perform 08-477 and...
Page 312
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 16 [D] Reproduction ratio adjustment of the secondary s canning direction (1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode) (2) Place a ruler on the original glass with its lea ding edge pushed against the original scale on the left. (3) Press [FAX] to make a copy at the mode of A3 (LD ), 100% and standard drawer of the equipment (Refer to *). *Perform 08-477 and check the value. If the value...
Page 313
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 17 3 [E] Image position adjustment of the secondary scann ing direction (1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode) (2) Place a ruler on the original glass with its lea ding edge pushed against the original scale on the left. (3) Press [FAX] to make a copy at the mode of A3 (LD ), 100% and standard drawer of the equipment (Refer to *). *Perform 08-477 and check the value. If the value is...
Page 314
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 18 [F] Top margin (1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode) (2) Open the platen cover or RADF. (3) Press [FAX] to make a copy at the mode of A3/LD, 100%, Text/Photo and standard drawer of the equipment (Refer to *). *Perform 08-477 and check the value. If the value is 0, use the lower drawer. If the value is 1, use the upper drawer. (4) Measure the blank area E at the leading edge...
Page 315
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 19 3 [G] Right margin (1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode) (2) Open platen cover or RADF. (3) Press [FAX] to make a copy at the mode of A3/LD, 100%, Text/Photo and standard drawer of the equipment (Refer to *). *Perform 08-477 and check the value. If the value is 0, use the lower drawer. If the value is 1, use the upper drawer. (4) Measure the blank area F at the right side of...
Page 316
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 20 [H] Bottom margin (1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode) (2) Open platen cover or RADF. (3) Press the [FAX] to make a copy at the mode of A3 /LD, 100%, Text/Photo and standard drawer of the equipment (Refer to *). *Perform 08-477 and check the value. If the value is 0, use the lower drawer. If the value is 1, use the upper drawer. (4) Measure the blank area G at the trailing...
Page 317
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 21 3 3.3 Image Quality Adjustment (Copying Function) 3.3.1 Density adjustment The center density and the density variation contro lled by density adjustment keys can be adjusted as follows. < Adjustment Mode (05) > * The values in “( )” are the adjustment codes of th e Custom Mode. Make a test copy and compare the image obtained wit h the current settings; if necessary, make adjust- ment using the following procedure. (1) While...
Page 318
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 22 3.3.2 Gamma slope adjustment Gamma slope is adjustable with the following codes. < Adjustment Mode (05) > * The values in “( )” are the adjustment codes of th e Custom Mode. Procedure is same as that of P.3-21 3.3.1 Density adjustment. Original mode Item to be adjusted Remarks Text/Photo Photo Text 593 (943) 594 (945) 595 (944) Gamma slope adjustment Ones place: 0: equivalent to the set value 5 1 to 9: Select the gamma slope...
Page 319
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 23 3 3.3.3 Sharpness adjustment If you want to make copy images look softer or shar per, perform the following adjustment. < Adjustment Mode (05) > * The values in “( )” are the adjustment codes of th e Custom Mode. Make a test copy and compare the image obtained wit h the current settings; if necessary, make adjust- ment using the following procedure. Procedure is same as that of P.3-21 3.3.1 Density adjustment. Original mode...
Page 320
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 24 3.3.4 Setting range correction The values of the background peak / text peak in th e range correction can be switched to “varied” or “fixed” in the following codes. If they are fixed, the range correction is performe d with standard values. The values of the background peak affect the reprod uction of the background density and the values of the text peak affect that of the text density. < Adjustment Mode (05) > * The values in...