Page 371

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 75
3
[B] Adjustment
(1) Close the RADF. 
(2) Adjust it by turning the adjustment screws on th e hinges.
 Adjust the height on the rear side by means of the  screw on the hinge on the feed side of the 
RADF.
Turn it clockwise  ................. Heightened 
Turn it counterclockwise ...... Lowered
 Fig.3-93
 Adjust the gap on the rear side by means of the scr ew on the hinge on the feed side of the 
RADF.
Turn it clockwis...

Page 372

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 76
3.11.3 Adjustment of Skew
Note: Note: 
Check if the image adjustment for the equipment is p erformed properly before this adjustment of 
the RADF.  Also, the RADF position and height shall  be adjusted properly.
[A] Checking 
Check the image using the chart (original) with vert ical and horizontal lines in the following procedure.
 Fig.3-95 Chart (Original)
Simplex copying:
(1) Place the chart provided as an original with its...

Page 373

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 77
3
[B] Adjustment 
Simplex copying: 
(1) Shift the aligning plate with the scale as the g uide shown in the figure below to adjust the skew.
 Fig.3-96
(2) If the image skew is C as shown in the figure  below, shift the aligning plate in the direction of 
+, and if D, shift it to -.
 Fig.3-97  Fig.3-98
Shift the aligning plate in the direction of +. Sh ift the aligning plate in the direction of -.
C
D
05/11 

Page 374

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 78
Duplex copying:
(1) Shift the aligning plate with the scale as the g uide shown in the figure below to adjust the skew.
 Fig.3-99
(2) If the image skew is C as shown in the figure  below, shift the aligning plate in the direction of -
, and if D, shift it to +.
 Fig.3-100  Fig.3-101
Shift the aligning plate in the direction of -.  S hift the aligning plate in the direction of +.
C
D
05/11 

Page 375

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 79
3
3.11.4 Adjustment of the Leading Edge Position
Note: Note:  Check if the image adjustment for the equipment is p erformed properly before this adjustment of 
the RADF.  Also, the RADF position and height shall  be adjusted properly.
[A] Checking 
Check the image using the chart (original) with vert ical and horizontal lines in the following procedure.
Simplex copying:
(1) Place the chart provided as an original with its  face up...

Page 376

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 80
Duplex copying:
(1) Turn the power ON while pressing [0] and [5] sim ultaneously, key in [366] and then press the 
[START] button.
(2) Enter the value.  If the leading edge (F) margin of the copy image i s larger than the (E) margin of the chart, 
enter a value smaller than the current one.
Note: Note:  Changing one value shifts the copy image by 0.1 mm. 
 If the leading edge (F) margin of the copy image i s smaller than the (E)...

Page 377

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 81
3
Note: Note:  Changing one value shifts the copy image by 0.042 mm .
 Fig.3-105
(3) Press the [ENTER] button.
H
05/11 

Page 378

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 82
3.11.6 Adjustment of Copy Ratio
Note: Note: 
Check if the image adjustment for the equipment is p erformed properly before this adjustment of 
the RADF.  Also, the RADF position and height shall  be adjusted properly.
[A] Checking 
Check the image using the chart (original) with vert ical and horizontal lines in the following procedure.
(1) Place the chart provided as an original with its  face up on the original tray of the...

Page 379

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 83
3
3.11.7 Adjustment of RADF Opening/Closing Sensor
Adjust the bracket position so that the sensor is t urned ON when the height “A” becomes 100 mm or 
less (within the empty weight falling limit).
 Fig.3-107 
 Fig.3-108
A
05/11 

Page 380

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 84
3.12 Adjustment of the Finisher (MJ-1022) 
3.12.1 Adjusting the jogging plate width

(1) Remove the right inner cover and the rear cover. 
(4) Measure the jogging width (standard at 317 mm).
(2) Adjust the front jogging plate to the home 
position. 
 Set SW1 on the finisher controller PC board as shown in   P.3-84 Fig.3-109 .
 Press SW2 twice on the finisher controller  PC board.
- The front jogging plate moves to the 
home...