Home > Toshiba > Printer > Toshiba Estudio 230 Manual

Toshiba Estudio 230 Manual

Here you can view all the pages of manual Toshiba Estudio 230 Manual. The Toshiba manuals for Printer are available online for free. You can easily download all the documents as PDF.

Page 381

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 85
3
(5) Remove the processing tray. 
(6) Loosen the screw on the home position sen- sor plate at the front.
 Fig.3-112
(7) Adjust the position of the front jogging plate home position sensor (S6) with reference to  
the index. 
 EX. 1If the width is 319 mm in step (4), the dif- 
ference from the standard is +2 mm, it  
requires relocation of the sensor in the  
direction of arrow A by 2 mm.
 EX. 2
If the width is 316 mm in step...

Page 382

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 86
3.12.2 Adjusting the angle of the jogging plate

(1) Without removing the processing tray unit,  loosen the 2 mounting screws of the rear jog- 
ging plate.
 Fig.3-114
(2) Place several sheets of A4/LT paper on the  processing tray, and adjust the rear jogging  
plate. (At this time, adjust the gap between  
the paper and the front end of the rear jog- 
ging plate so that it is 0 mm to 0.5 mm.)
 Fig.3-115
(3) With reference to the...

Page 383

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 87
3
3.12.3 Adjusting the overlap of the sensor flag
If the overlap between the sensor and the flag is w rong for some reason, perform the following adjust-
ment. 

(1) Remove the processing tray unit. 
(2) Loosen the mounting screw of the front/rear  jogging plate adjusting plate; then, move the  
adjusting plate to the left and the right.
 Fig.3-116
(3) Tighten the screw so that the overlap 
between the flag of the front/rear...

Page 384

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 88
3.12.4 Adjusting the tension of the stack processing
 motor belt

(1) Remove the right inner cover and the rear cover. 
(2) Remove the 2 mounting screws, and detach  the grip unit.
 Fig.3-118
(3) Loosen the screw on the tension arm plate.
(The tension arm plate will be pulled under  
tension by the tension spring.)
 Fig.3-119
(4) Move the returning roller shaft to its lower 
limit (the slack of a belt is lightly taken); then,...

Page 385

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 89
3
(5) Check to make sure that the returning roller  shaft moves smoothly.
 Fig.3-121
Returning 
roller shaft 

Page 386

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 90
3.12.5 Releasing the stack tray guide lever fixing p
late

(1) Remove the right inner cover and the rear  cover.
(2) Remove the finisher control PC board, PC  board bracket and sensor PC board.
(3) Remove the stack tray. 
(4) Remove the stack tray drive unit. 
(5) Place the stack tray guide lever fixing plate  so that it is in view through the hole in the  
side plate (front, rear). Then remove the fix-
ing screw. (Perform the...

Page 387

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 91
3
3.12.6 Adjustment of the upper tray angle

(1) Remove the front cover.
 Fig.3-124
(2) Loosen the screw denoted with the arrow.
 Fig.3-125
(3) The tension becomes loose. While pushing the bracket down, hold the  
tray and move it up or down, to adjust the 
angle so that the tray becomes parallel by a 
visual check.
 Fig.3-126
Bracket 

Page 388

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 92
(4) After adjustment, tighten the fixing screw of  the bracket.
Note: Note: If the fixing screw of the bracket is not fixed,  
the belt is loosened which may cause a  
skipped tooth.
 Fig.3-127 

Page 389

June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 93
3
3.12.7 DIP switch functions
You can simulate various functions by setting the D IP switch (SW1) on the finisher controller PC board 
appropriately. 
Initiating Operations 
1) Remove any obstacles from the area of operation. 
2) Set the DIP switch (SW1) as shown, and turn ON th e power (so that LED1 will start to blink).
3) Press the pushing switch (SW2) twice to initiate  the operation in question. (LED2 will remain on dur-
ing...

Page 390

e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
3 - 94
Note: Note:  Perform the shipping position operation when the fi nisher is packed again.
Lower stack tray  
motor (down)The lower stack tray moves down 
and stops when the lower stack tray  
lower limit sensor is turned ON.  Press SW2 again. 
 Turn OFF the joint 
sensor (S4).
Stapler motor The stapler motor stops after the sta- pling operation.  Press the stapler 
safety switch (S14).
 Turn OFF the joint  sensor (S4).
Shipping...
Start reading Toshiba Estudio 230 Manual

Related Manuals for Toshiba Estudio 230 Manual

All Toshiba manuals