Home > Samsung > Communications System > Samsung Idcs 500 General Description Manual

Samsung Idcs 500 General Description Manual

Here you can view all the pages of manual Samsung Idcs 500 General Description Manual. The Samsung manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 21

iDCS 18D KEYSET
(See Figure 2–2)
!32 character display (2 x 16) with three
associated soft keys and a scroll key
!18 programmable keys with tri-colored
lights
!Four fixed function keys
!Terminal Status Indicator
!Built-in speakerphone
!Eight selectable ring tones
!UP/DOWN buttons for digital control of
speaker, handset and ringer volumes
!Desk- or wall-mounted
!Available in dark gray or light gray
FIGURE 2–1
FIGURE 2–2
iDCS 28D KEYSET
(See Figure 2–1)
!32 character display (2 x 16) with three
associated...

Page 22

iDCS 8D KEYSET
(see Figure 2–3)
!32 character display (2 x 16) with three asso-
ciated soft keys and a scroll key
!8 programmable keys with tri-colored lights
!Four fixed function keys
!Terminal Status Indicator
!Built-in speakerphone
!Eight selectable ring tones
!UP/DOWN buttons for digital control of
speaker, handset and ringer volumes
!Desk- or wall-mounted
!Available in dark gray or light gray
iDCS 64B AOM
(See Figure 2–4)
!64 programmable keys with red lights
!A maximum of 2 can be assigned to any...

Page 23

iDCS KDB-DIGITAL LINE INTERFACE (FKDBD)
This is a daughterboard that can be installed only in the 18 or 28 button keyset. The
FKDBD will provide one additional DLI circuit for the connection of any digital station de-
vice such as a keyset, add-on module or DPIM. This FKDBD will only operate when the
keyset is connected to an 8 port DLI card so it can use the second B channel. Each port on
this card is intended for connection to one telephone. Connecting multiple telephones to
a port may result in...

Page 24

2.4.2 DCS SERIES EQUIPMENT
LCD 24B KEYSET (See Figure 2–6)
!Built-in speakerphone
!24 programmable keys (16 with tri-col-
ored LEDs)
!Four fixed function keys
!32 character display (2 x 16) with three
associated soft keys and a scroll key
!UP/DOWN buttons for digital control of
speaker, handset and ringer volumes
!Eight selectable ring tones
!Desk- or wall-mounted
!Available in almond or charcoal
LCD 12B KEYSET (see Figure 2–7)
!32 character display (2 x 16) with three
associated soft keys and a scroll...

Page 25

FIGURE 2–11
32 BUTTON ADD-ON MODULE (AOM)
(see Figure 2–9)
!32 programmable keys
!Two fixed function keys
!UP/DOWN buttons for digital control of
speaker and ringer volumes
!Available in almond or charcoal
!One or two can be assigned to any DCS
keyset to provide executive off-hook voice
announce and additional programmable
keys (see Figure 2–10)
!Can operate as a stand-alone handsfree tele-
phone unit
DOOR PHONE INTERFACE
MODULE (DPIM) & DOOR PHONE
(see Figures 2–11 and 2–12)
!The DPIM adapts any DLI...

Page 26

SINGLE LINE TELEPHONE
(See Figure 2–14)
!Four fixed function keys: hold, flash, new
call, and monitor.
!Data Port: selectable to share station ex-
tension or utilize a separate extension
!On hook dialing
!Message Waiting/Ring Indicator
!Desk or wall mounted
!Ring volume control,
!Four available ring tones.
!Available in almond and black
Note: This single line telephone set is FCC approved for direct connection to the public telephone network.
FCC # A3LKOR-24627-TE-T   REN 0.9B  UL LISTED 19X9   FILE #...

Page 27

KDb-DLI
This is a daughterboard that can be installed only in the 12 or 24 button keyset. The KDb-
DLI will provide one additional DLI circuit for the connection of any digital station device
such as a keyset, add-on module or DPIM. This KDb-DLI will only operate when the keyset
is connected to an 8 port DLI card so it can use the second B channel. Each port on this
card is intended for connection to one telephone. Connecting multiple telephones to a
port may result in incorrect operation or damage to...

Page 28


				            

Page 29

PART 3. SPECIFICATIONS
The following tables provide technical data for the iDCS 500 hybrid/key telephone sys-
tem.
3.1aELECTRICAL SPECIFICATIONS (PSU 60)
AC INPUT 120  (88–132) VAC (48–63 Hz)*
220 (180–260) VAC (48–63 Hz)
POWER CONSUMPTION (MAX)120 WATTS MAX. PER PSU FUSE RATING 3 AMP
BTU RATING (MAX) 6.8 BTU/MINUTE
DC OUTPUT +5 VOLTS 5.0 AMPS MAX
-5 VOLTS 0.5 AMPS MAX
-48 VOLTS 1.4 AMPS MAXIMUM
-56 VOLTS Charger 0.45 AMPS MAX
*Normal factory setting
3.1bELECTRICAL SPECIFICATIONS (PSU 60B)
AC INPUT...

Page 30

3.2DIMENSIONS AND WEIGHTS
HEIGHT WIDTH DEPTHWEIGHT
iDCS 500 BASIC SYSTEM:
SINGLE CABINET 17.5 22.5 12 35  lb.
EXPANDED SYSTEM: TWO CABINETS 35 22.5 12 70  lb.
EXPANDED SYSTEM: THREE CABINETS 52.5 22.5 12105 lb.
DIGITAL KEYSET (ALL MODELS) 4.25 8.50 9 2.563  lb.
ADD-ON MODULE4.25 4.25 9 1.188 lb.
DOOR PHONE 5 3.88 1.25 6.8 oz.
3.3ENVIRONMENTAL LIMITS
OPERATING TEMPERATURE 32–104 °F/0–40 °C
STORAGE TEMPERATURE -13–158 °F/-25–70 °C
HUMIDITY...