Page 11

PART 2. HARDWARE DESCRIPTIONS
2.1 SYSTEM CABINETS
The cabinets that make up the iDCS 500 system are of metal construction and may be
utilized as either as an expansion cabinet or as a main cabinet / key service unit (KSU).
The cabinets may be used singly or may be stacked up to three (3) high to achieve maxi-
mum capacity. A single cabinet may be wall mounted for smaller applications or alterna-
tively the system may be mounted in a standard nineteen inch (19”) equipment rack after
removal of the side...

Page 12

the RCM or the Local Area Network (LAN) board in a single cabinet system. This position
is also required to support the Inter Processor communications and Memory (IPM) daugh-
ter board in a multiple cabinet system or a system running the L version software. The
third daughter board (MCP_D3) can support a Miscellaneous (MISC) daughter board or a
Local Area Network (LAN) daughter board in a single cabinet system or a LAN daughter
board in a multiple cabinet system.
* The ESM must be installed in this...

Page 13

LOCAL CONTROL PROCESSOR (LCP)
The Local Control Processor (LCP) card is installed in a dedicated processor slot, slot 10,
of each Expansion KSU and does not reduce the available universal card slots of that
cabinet. The LCP card has positions for three daughter boards. The first daughter board
position (SCP-D1) can support one of two types of daughter board, a Multi-Frequency
Module (MFM), or an R2/CID Module (RCM). The second daughter board position (SCP-
D2) can support the MFM, the RCM or the MISC....

Page 14

LOCAL AREA NETWORK (LAN)
This daughter board installs in either position MCP-D2 or MCP-D3 of the Main Control
Processor and provides a 10/100 base T Ethernet LAN connection. In addition to the LAN
connection, the LAN board provides 0.5 megabytes of SRAM to support the increased I/O
functions of this card. The LAN board also provides the hardware to drive the third and
fourth Serial I/O ports in the main cabinet.
The LAN daughter board consists of the following:
!10/100 base T LAN Interface
!0.5 Megabytes...

Page 15

R2/CID MODULE (RCM)
The R2/CID Module installs in any position on any of the processor cards. The main pur-
pose of the RCM daughter board is to provide Caller ID decoders for use with that tele-
phone company provided service over analog trunks. A secondary use of the RCM is to
provide R2 MFC senders and receivers to the system although these are not used in the
US. The system can support up to three of these cards for a total of 42 CID receivers.
The RCM consists of the following:
!Fourteen (14) CID...

Page 16

2.2.5  MODEM DAUGHTER BOARD
The Modem daughter board installs on the Input Output Modem card. The modem pro-
vides a 38.4K connection or with the LAN board installed 56K/V90 connection to the sys-
tem for use for remote administration and/or programming. The card has a default exten-
sion number of 3999 and eliminates the need for an external modem, serial cable, single
line telephone port and serial I/O port on the system.
2.3 INTERFACE CARDS
These cards provide the interface connections for telephone...

Page 17

TEPRI DIGITAL TRUNK
When programmed as a T1 this card provides up to 24 trunk circuits in any combination of
the following:
!Loop start lines
!DID (Direct Inward Dialing)
!Ground start lines
!E & M tie lines or two way DID calling
When the card is programmed as a PRI it will provide 23 bearer channels and 1 data
channel (23B+D). This card can be installed in any of the first three slots of any cabinet.
4 BRI (BASIC RATE INTERFACE–4BRI)
The 4 BRI card supports 4 trunk or station level ISDN Basic Rate...

Page 18

2.3.2  STATION CARDS
DLI
This card is an eight circuit digital station interface card that provides 2B+D service when
installed in any universal card slot in all cabinets.
16DLI
This card is a sixteen circuit digital station interface card that provides 1B+D service when
installed in any universal card slot in all cabinets. Keyset daughter boards will not work
when connected to this card.
SLI
This card is a four circuit analog station interface for industry standard single line tele-
phones or other...

Page 19

at a programmable rate of 100ms to 2000ms ON/OFF times. The 8MWSLI does not con-
tain any over-voltage protection and is not qualified as OPX. It also does not contain DTMF
receivers, but instead shares the system DSP resources. It can be inserted in any univer-
sal card slot in all cabinets. Each port on this card is intended for connection to one tele-
phone. Connecting multiple telephones to a port may result in incorrect operation or dam-
age to the card. See the installation manual part 3 for...

Page 20

2.3.3  OTHER CARDS
AUTO ATTENDANT
This optional card can be used for either the Automated Attendant, Uniform Call Distribu-
tion or a combination of both. For more information about the Automated Attendant and
UCD, see section 4.1 System Features.
CADENCE (CVM8A)
The CADENCE Voice Mail system is a fully integrated Auto Attendant/Voice Mail/Fax Sys-
tem on a single DCS circuit card. This optional card is designated the CVM8A and pro-
vides 4 or 8 channels of communication. Only one card is permitted per...