Page 151

Installing PageWriter Trim I SoftwareObtaining Software
PageWriter Trim Cardiograph Service ManualA-3
To load the software upgrade files to the PC card:
1
Insert the memory card into the PC card adapter as shown. 
2Insert the PC card into a compatible slot on a computer or other device.
3Go to the InCenter site (incenter.medical.philips.com) and enter your login information.
NOTEFor information on registering for the InCenter site, see “Using the Philips InCenter Site” on 
page 1-26.
4
On the top menu...

Page 152

Installing PageWriter Trim I SoftwareObtaining Software
A-4PageWriter Trim Cardiograph Service Manual
8The InCenter software download license agreement appears. If you agree to the terms of 
the agreement, click 
I agree. 
NOTEA message may appear that the Download Manager application needs to be installed. Click as 
indicated to install the ActiveX control in order to continue with the software download. See the 
InCenter main page for more information on installing and using ActiveX controls with the...

Page 153

Installing PageWriter Trim I SoftwareInstalling the Software Upgrade
PageWriter Trim Cardiograph Service ManualA-5
Installing the Software Upgrade 
To install the software upgrade:
1
Peel off the protective covering from the rear panel of the cardiograph to expose the PC 
card slot.
Figure A-5 Removing the protective cover 
2
To protect against static discharge, touch the PC card (with memory card inserted into the 
adapter) to the grounding post on the rear of the cardiograph. 
Figure A-6 Grounding post...

Page 154

Installing PageWriter Trim I SoftwareInstalling the Software Upgrade
A-6PageWriter Trim Cardiograph Service Manual
3Ensure that the Patient Interface Module (PIM) is securely attached to the connector on the 
rear of the cardiograph.
Figure A-7 Connecting the PIM to the cardiograph
4
Insert the PC card into the PC card slot. 
Figure A-8 Inserting the PC Card
5
Connect the cardiograph to AC power. Verify that the green LED on the front of the 
cardiograph is lit.
  WARNINGAlways connect the cardiograph to...

Page 155

Installing PageWriter Trim I SoftwareInstalling the Software Upgrade
PageWriter Trim Cardiograph Service ManualA-7
appearing on the screen. If the buttons are not pressed in time, press the On/Off button to 
turn off the cardiograph. Press the On/Off button again and repeat the procedure.
8A prompt appears to enter a password. Press the following keys in sequence: Patient ID, 
Auto, Rhythm, Copy, Page. Press the Stop key to delete your last input if it is wrong. 
The Biomed Service Program screen...

Page 156

Installing PageWriter Trim I SoftwareInstalling the Software Upgrade
A-8PageWriter Trim Cardiograph Service Manual
11Turn the Trim Knob to highlight the arrow icon, then press the Trim Knob to return to the 
main menu.
12Turn the Trim Knob to highlight Upgrade, then press the Trim Knob to select it. ABU United Kingdom 
EnglishEnglish IEC A4
ABX Finland
EnglishEnglish IEC A4
ABZ European Italian Italian IEC A4
AC4 Brazil Portuguese Portuguese AAMI A
AC6 South Korea
EnglishEnglish AAMI A4
AC8 Argentina...

Page 157

Installing PageWriter Trim I SoftwareVerifying the Software Installation
PageWriter Trim Cardiograph Service ManualA-9
13Turn the Trim Knob to highlight Upgrade All and then press the Trim Knob to select this 
installation option.
14Turn the Trim Knob to highlight Start, then press the Trim Knob to select it. Information 
on the status of the upgrade installation appears on the screen. 
15When the installation is complete, the cardiograph automatically shuts down. 
Remove the PC card from the...

Page 158

Installing PageWriter Trim I SoftwareVerifying the Software Installation
A-10PageWriter Trim Cardiograph Service Manual
cardiograph has passed the printer test. If the printer test page does not match the printer 
test points, the cardiograph has failed the print test. 
Table A-3 Printer Test Page Description 
Test Point Description
A The stepped bars are sharp edged and printed cleanly without distortion 
or missing segments 
B The spacing between the vertical lines is 25 mm with a discrepancy of 
no...

Page 159

Installing PageWriter Trim I SoftwareVerifying the Software Installation
PageWriter Trim Cardiograph Service ManualA-11
Figure A-9 Printer Test Page
11
Press the Patient ID button if the cardiograph passed the printer test. 
12When the Self Test is complete, press the Patient ID button on the cardiograph to print out 
a report of the test results.
A
B
C
D 

Page 160

Installing PageWriter Trim I SoftwareVerifying the Software Installation
A-12PageWriter Trim Cardiograph Service Manual
13On the printed test report, check the software revision level next to Release Version 
(lower right side of report). The revision level should read 
A.01.01(Figure A-10 on 
page A-12) or 
A.01.03 (Figure A-11 on page A-13). Check that the correct localization 
option appears next to 
Country Options, see Table A-3 on page A-7.
Figure A-10 Software Version A.01.01 Self Test Report...