Home > Panasonic > Recording Equipment > Panasonic Matrix Switcher Wj Sx550c Operating Instructions

Panasonic Matrix Switcher Wj Sx550c Operating Instructions

Here you can view all the pages of manual Panasonic Matrix Switcher Wj Sx550c Operating Instructions. The Panasonic manuals for Recording Equipment are available online for free. You can easily download all the documents as PDF.

Page 51

53
3
Connection with the Monitors and Time Lapse VCRs
Connect the Monitors to the Monitor Output Connectors (MONITOR OUT) on the Video Output Board(s).
Connect the Time Lapse VCR as shown in the example below.
TL
TL
TL
TL
246810121416
ALARM
IN 1
COM2ALARM
RESET IN 3ALARMRECOVER OUT4
ALARM
OUT 5
1 SHOT IN67TAPE END
OUT8
WARNING
OUT 9
HUMID OUT10REC OUT 11REC REVIEW
OUT12
SERIES
REC IN 13
14TIME
ADJUST IN 15TIMEADJUST OUT16 COMSERIES
REC OUT
13579111315
OUT    IN
OUT
   IN
OUT    IN
OUT    IN
MONITOR...

Page 52

54
3
Connection with the System Controllers
Data Line Connection
Up to eight WV-CU550C System Controllers can be installed in a  Matrix System.
The Control Board installed in the WJ-SX550C Matrix Switcher has eight ports that correspond to eight WV-CU550C System
Controller inputs.
If the supplied 6-conductor cable assembly is used, simply plug one end of the cable into a port on the Control Board and the
other end into one of the ports on the rear of the System Controller.
If you use cables assembled...

Page 53

55
3
Direct connection to the Control Board (“Home Run” Type Wiring)
In this type of installation there is one control cable directly connecting each System Controller to one Control Board port.
Refer to the connections and controller settings in the figure shown below.
INOUTTERMON OFF
DATA
0123456789
CONTROLLER
UNIT NO.
1-8
Controller 1
INOUTTERMON OFF
DATA
0123456789
CONTROLLER
UNIT NO.
1-8
Controller 2
INOUTTERMON OFF
DATA
0123456789
CONTROLLER
UNIT NO.
1-8
Controller 3
INOUTTERMON OFF
DATA...

Page 54

56
3
Indirect connection to the Control Board (“Daisy-Chain” Type Wiring)
In this type of installation only one control cable directly connects between the System Controller #1 and the Control Board.
The rest of the System Controllers connect to System Controller #1 in a Daisy-Chain connection.
Refer to the connections and controller settings in the figure shown below.
INOUTTERMON OFF
DATA
0123456789
CONTROLLER
UNIT NO.
1-8
Controller 1
INOUTTERMON OFF
DATA
0123456789
CONTROLLER
UNIT NO.
1-8
Controller...

Page 55

57
3
Combination of direct and indirect connections
(Both “Home Run” and “Daisy-Chain” wiring in one system)
In this type of installation there is a mixture of wiring methods, with some System Controllers connecting directly to the Control
Board while other System Controllers connect to the Control Board through other System Controllers.
Refer to the connections and controller settings in the figure shown below.
INOUTTERMON OFF
DATA
0123456789
CONTROLLER
UNIT NO.
1-8
Controller 1
INOUTTERMON OFF
DATA...

Page 56

58
3
Connection with the Alarm Sensor Units
Connect the sensor switches to the Alarm Input Connector
on the Alarm Board as shown in the example below.1-32
37
2019
1Alarm Sensor
#32 Common (Ground)
Alarm Sensor
#1 Alarm Sensor
#2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Alarm 8
Alarm 9
Alarm 10
Alarm 11
Alarm 12
Alarm 13
Alarm 14
Alarm 15
Alarm 16
Alarm 17
Alarm 18
Alarm 19Alarm 65
Alarm 66
Alarm 67
Alarm 68
Alarm 69
Alarm 70
Alarm 71
Alarm...

Page 57

59
3
Connection between the Data Board and Camera Site
Connect the Data Board and the Camera Controller (or specified camera) using the specified data cable.
A basic connection is shown in the figure below.
DATA(RS485)
A
T
B
1A
R
B
G
A
T
B
2A
R
BGND
DATAT(A) T(B) R(A) R(B)
Then make the following settings on the Setup Menu of each component.
•Matrix Switcher
Set Up
F1:-- F2:-- F3:DEL F4:PopSystem RS-485
RS-485
Site Communication
#1
Up
#2
Daisy
#3
#4
#5
#6
#7
#8
NumberF/HDuplexDelayTimeBaudRateWaitTime...

Page 58

60
3
2-Line (Half Duplex) Connection
TXD
TB
RA (+)
RB
GNDRXDTA (+)
DATA(RS485)A
T
B
1A
R
B
G
A
T
B
2A
R
B
G
A
T
B
3A
R
B
G
A
T
B
4A
R
B
G
A
T
B
5A
R
B
G
A
T
B
6A
R
B
G
A
T
B
7A
R
B
G
A
T
B
8A
R
B
G
R(A)
R(B)
GND
T(A)
T(B)
GND
S W
SW100, 150,  200, 250
      300, 350, 400, 450
HALF: 2 lines(Internal Switch: SW5, 2 lines)
TA (+)
TB
RA (+)
RB
GND
1
TA (+)
TB
RA (+)
RB
GND2
TA (+)
TB
RA (+)
RB
GND
3
TA (+)
TB
RA (+)
RB
GND4
TA (+)
TB
RA (+)
RB
GND
5
TA (+)
TB
RA (+)
RB
GND
6
TA (+)
TB
RA (+)
RB
GND
7
TA (+)...

Page 59

61
3
Indirect Connection between the Data Board and Camera Controllers (“Daisy-Chain” Type Wiring)
In this type of connection only one control cable directly connects between Data Connector #1 and Camera Controller #1. The
rest of the Camera Controllers connect to Camera Controller #1 in a Daisy-Chain connection. Refer to the connections and set-
tings shown below.
4-Line (Full Duplex) Connection
TXD
TB
RA (+)
RB
GNDRXDTA (+)
DATA(RS485)A
T
B
1A
R
B
G
A
T
B
2A
R
B
G
A
T
B
3A
R
B
G
A
T
B
4A
R
B
G
A
T
B...

Page 60

62
3
Matrix Switcher
WJ-SX550C
Camera In Number #4 - - - Camera In Number #2 - - -
Set the Matrix Switcher and the Camera Controllers (up to 8) as shown below.
Models
Parameters
Daisy : On
Camera Controller
WV-RM70
F/H Duplex : Full
Camera In Number #1 - - - Unit Number: 1
Unit Number: 2
Camera In Number #3 - - - Unit Number: 3
Unit Number: 4
Camera In Number #5 - - - Unit Number: 5
Camera In Number #6 - - - Unit Number: 6
Camera In Number #7 - - - Unit Number: 7
Camera In Number #8 - - - Unit Number: 8...
Start reading Panasonic Matrix Switcher Wj Sx550c Operating Instructions

Related Manuals for Panasonic Matrix Switcher Wj Sx550c Operating Instructions

All Panasonic manuals