Page 31
33 2 WV-CU550C System Controller Appearance Front View 123 456 789 MON CAM ESC SET0 ACK RESETBACK SEQFORWARD SEQALT DEC –1CAMINC +1CAM STOP SLOW12AUX CLOSEOPEN IRISPRESET FOCUS NEAR ZOOM TELE FAR WIDE System Controller WV-CU550 LEFT RIGHTUP DOWN ALARMBUSY F3F4F2F1 C AF qwert y uio!0!1!2!3!4!5!6!7 @1 !9 !8 @0 CONTROLLER ON OFFINOUTTERMON OFF DATA 0123456789 CONTROLLER UNIT NO. 1-8MODE #1#2#3#4#5#6 Rear View
Page 32
34 2 qAlarm Indicator (ALARM) Blinks to indicate that an alarm condition exists. To turn the indicator off, press the ACK RESET button. wBusy Indicator (BUSY) Lights up when you attempt to control a monitor or a camera that is already used by a higher priority opera- tor, or when the higher priority operator selects the monitor or camera you are currently operating. Operations from the System Controller are disabled until this indicator goes off. eFunction Buttons (F1/F2/F3/F4) Select functions displayed...
Page 33
35 2 #4Mode Selection Switch (MODE) These switches are used to set the mode of the System Controller connected to the Matrix Switcher. Set the switches as shown below. #5Controller On/Off Switch (CONTROLLER ON/OFF) This switch is used to turn the WV-CU550C system controller power on and off. #6Power Cord !7Auxiliary Button (AUX 1,2) These buttons toggle the auxiliary switches in the Receiver on and off. The auxiliary switches can be used, for example, to activate equipment connected to the receiver, such...
Page 34
36 2 OPERATE Extension Unit WJ-AD550 q WJ-AD550 Extension Unit Appearance Front View OFF +9V+5V−5V POWER ON 11A00001 Extension 1 2 WJ-SX550A Extension 1 2 DATA ADDRESS12345678 ON OFFDATA ADDRESS12345678 ON OFF WJ-AD550WJ-SX550AWJ-AD550 w e r t y Rear View qOperate Indicator (OPERATE) Is on when the power of the WJ-AD550 Extension Unit is turned on. wExtension Board (EXTENSION) One of these boards is installed in the WJ-SX550C Matrix Switcher. Connect these boards using the 25- pin connection cables...
Page 35
37 2 Extension Board Appearance qExtension Port (1, 2) These ports are used to expand the Matrix Switcher System. Connect between these ports on the boards installed in the WJ-SX550C Matrix Switcher and the WJ-AD550 Extension Unit. wData Address Switch (DATA ADDRESS ON/OFF) These switches are used to identify the unit address number of the WV-PB5548 Data Board installed in the WJ-AD550 Extension Unit. Set switches on the board installed in the WJ-SX550C Matrix Switcher to the “ON” posi- tion designate...
Page 36
38 2 Board Setting Before installing this board, the following settings should be made by qualified service personnel or system installers. SW1 AD550 SX550A SW3 AD550 SX550A 1. Set switches (SW1 and SW3) on the board to reflect the system configuration as shown below. SX550A:Set to this position when the board is installed in the WJ-SX550C Matrix Switcher. AD550:Set to this position when the board is installed in the WJ-AD550 Extension Unit. The factory default setting is AD550 position. SW1 AD550...
Page 37
39 2 WV-PB5564 Alarm Board Appearance qAlarm Number Display Indicates the alarm input number when an alarm is received from the associated alarm sensor. Note:The display indicator lights up as shown below when the alarm number is over one hundred. ALARM TEST 1-32 5 RESET MODE 33-64 q w e r tIndicator wMode Selection Switch (MODE) This rotary switch, in combination with the Test button, is used to select the alarm test mode. Mode 0:Press the Test button to receive an alarm number display in...
Page 38
40 2 Alarm Signal tAlarm Input Port (1-32, 33-64) This port accepts alarm input from the associated alarm sensors through either Normally Open or Normally Closed con- tacts. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19Alarm 1 Alarm 2 Alarm 3 Alarm 4 Alarm 5 Alarm 6 Alarm 7 Alarm 8 Alarm 9 Alarm 10 Alarm 11 Alarm 12 Alarm 13 Alarm 14 Alarm 15 Alarm 16 Alarm 17 Alarm 18 Alarm 19Alarm 65 Alarm 66 Alarm 67 Alarm 68 Alarm 69 Alarm 70 Alarm 71 Alarm 72 Alarm 73 Alarm 74 Alarm 75 Alarm 76 Alarm 77 Alarm78...
Page 39
41 2 SW1 Setting 1. Set switches (SW1) on the board to designate the Alarm Input board number as shown below. 1 12OFF SW1 12OFF SW12 UNIT ADR SW4 2SW5 3SW6 4SW7 5SW8 6SW9 7SW10 8SW11 2. Set switches (SW4, SW5, SW6, SW7, SW8, SW9, SW10 and SW11) on the board to meet the alarm input requirements. NOR OPEN:Normally Open Input NOR CLOSE:Normally Closed Input The factory default setting is Normally Open (NOR OPEN). Board No. 12 OFF 12 OFF 1 21-64 65-128Alarm Input No. 1 2 OFF SW1 UNIT ADR 65-72 73-80 81-88...
Page 40
42 2 WV-PB5548 Data Board Appearance qData Connector (TA/TB/RA/RB/G, 1 - 8) These connectors are used to exchange control data with the camera site equipment. For connection, use a data grade shielded 4-wire twisted pair cable suitable for RS-485 communication. Cable length may be extended up to 1 200 m (4 000 ft). DATA(RS485) A T B 1A R B G A T B 2A R B G A T B 3A R B G A T B 4A R B G A T B 5A R B G A T B 6A R B G A T B 7A R B G A T B 8A R B G q TB RA (+) RB GNDR T TA (+) S W 1 RT: Termination...