Page 11
Notes:The desired monitor selection may not be avail- able due to one of the following reasons: • The System Controller used for selecting a particu- lar monitor is not allowed access to that monitor because of controller partitioning. See page 18 for more details. • The desired monitor is currently selected by anoth- er operator who has a higher operator priority, and therefore, control over that monitor. In this case, “Monitor Busy” or “NOT AVAILABLE” will be displayed on the LCD Display of the System...
Page 12
13 1 Sequence This system has three kinds of sequential modes: Program, Tour and Group Program Sequence The Program Sequence is a series of 64 steps assigned to a particular monitor. Each step has a Camera and Dwell Time assigned to it. In the Program Sequence, each monitor has its own specified sequence operation as shown below. •Auto Skip Function The Auto Skip function is available in sequence mode. If there is no video signal present at a step, the sequence will auto- matically skip that step....
Page 13
Group Sequence A Group Sequence consists of up to 64 steps. In each step, a maximum of 16 cameras can be assigned to 16 monitors. Pan/Tilt preset and Auxiliary control (1 & 2) can also be set for each camera/monitor combination. Camera view switching (Dwell Time) for each step can be set from 1 second to 30 seconds in 1-second increments. There are 8 Group Sequences available, with programming performed on the Set Up Menu. Timer Event The timer function is used to program and automatically activate...
Page 14
15 1 Examples of these modes are described below. Alarm Mode 1:Any alarmed pictures are assigned to Monitor 1. Mode 1 displays all alarms on Monitor 1. If more than one alarm is activated, the system will sequentially display the alarms on Monitor 1. Alarm Mode 2:Any alarmed pictures are assigned to four Monitors (1 - 4). Mode 2 displays the first alarm on Monitor 1. When the second alarm is received, the first alarm is shifted to Monitor 2 and the second alarm is displayed on Monitor 1 and so on. This...
Page 15
16 1 Operator Registration On the Operator Registration tables, an operator’s level, priority, password and camera access limits can be programmed. Up to 30 operators may be registered. For example: Level Setting Operator access to various setup functions and system operations is determined by the operator’s level. There are five separate levels available (Level 1 is the highest). Priority When two or more operators attempt to perform the same function at the same time, the operator with the higher...
Page 16
17 1 Camera Title and On-screen Display A camera title for each camera input is available for display on the monitor screen. Each title is composed of 15 characters per line, times 2 lines. All items listed below, except Alarm On/Off and Timer mode, can be included or excluded from display on the selected moni- tor screen. MAY 0700 14:23:56 AL1 /T32 C 01 M16 3rd Floor Pr64 T32 Room 306qw e i u t r yqDate and Time wAlarm On/Off AL0: Camera Site Alarm AL1: Interface Alarm...
Page 17
System Controller-Monitor Partitioning This feature is used to prevent specific WV-CU550C System Controllers from controlling the outputs of specific monitors. It prevents an operator from unintentionally gaining control over a monitor that may not be associated with his/her station. For example: The following example demonstrates the use of both system controller-monitor partitioning and operator priority. • Camera: 8 sets • Monitor: 3 sets • System Controller: 3 sets • Operator : 3 persons Setting...
Page 18
19 1 Synchronizing the Sequence with External Timing The camera switching interval (Sequence Dwell Time) can be synchronized with the time lapse mode set in the associ- ated Time Lapse VCR. Select the On or Off mode on the EXT Timing Select table to meet each monitor’s requirements. Caution:Set the interval time for the external timing signal of the external equipment to 1 second or more. If the interval is set to less than 1 second, the system will not work properly. Cable Compensation/VD2 Cable...
Page 20
22 2 Rear View MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS WJ-SX550C Matrix Switcher Appearance Front View OPERATE Matrix Switcher WJ-SX550C q CPURS-232C TIME ADJUST IN COM PRINTER OUT IN VS/VD VD OUT OFF +9V+5V−5V POWER ON 11A00001 INPUT 1 2 3 4 5 6 7 8 CAMERA IN VIDEO OUT1 VIDEO OUT2 CONTROLDATA 1 DATA 2 OUT IN1 OUT IN2 OUT IN3 OUT IN4MONITOR ALARM OUT RESET OUTEXT TIMING INRECOVER IN OUTPUTCAUTION 125V 4A DATA 3 DATA 4 DATA 5 DATA 6 DATA 7 DATA 8 DATA 1 DATA 2 wert y u i o