Home
>
Panasonic
>
Communications System
>
Panasonic Kx-Td308 Digital Super Hybrid System Installation Maintenence Manual
Panasonic Kx-Td308 Digital Super Hybrid System Installation Maintenence Manual
Here you can view all the pages of manual Panasonic Kx-Td308 Digital Super Hybrid System Installation Maintenence Manual. The Panasonic manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 201
3FeaturesS Station Programming DescriptionAllows the proprietary telephone (PT) user to customize the extension to their needs. The following programming items are available: For the PT (RX-T7220; RX-T7230; RX-T7235; RX-T7250; KX- T7 130; RX-T7020; RX-T7030; RX-T7050) Call Waiting Tone Type Assignment Flexible CO Button Assignment Full One-Touch Dialing Assignment Intercom Alert Assignment Preferred Line Assignment - Incoming / Outgoing Station Programming Data Default Set For digital PT (RX-T7220;...
Page 202
S3Features Station Programming Data Default Set DescriptionAllows the proprietary telephone user to return all the following items programmed on the telephone to default setting.Programming Items Bilingual Display Selection Call Waiting Tone Type Assignment Full One-Touch Dialing Assignment Handset / Headset Selection Initial Display Selection Intercom Alert Assignment Live Call Screening Mode Set Preferred Line Assignment - Incoming Preferred Line Assignment - OutgoingDefault English Display Tone 1...
Page 203
Features Station Speed Dialing DescriptionAllows an extension user to store frequently dialed numbers in order to place a call with abbreviated dialing. It is performed by dialing the feature number and a speed dial number from 0 through 9. Up to 10 numbers can be stored in each telephone. Conditionsl Station Speed Dialing can be followed by manual dialing to supplement the dialed digits. l You may make a call with One-Touch Dialing button, instead of Station Speed Dialing. l The standard telephone may...
Page 204
S System Data Default Set 3Features DescriptionThis system permits re-initialization of system-programmed data. If all the programmed data is cleared, the system will restart with the default setting. ConditionsThe default setting for each programming item is listed in Section 5.2, “Default Values”. Programming References Section 4, System Programming [900] System Data Clear Feature ReferencesNone Operation ReferencesSection 2, Installation 2.9 System Data Clear3-144Features
Page 205
3FeaturesS System Programming with Proprietary Telephone DescriptionThis system can be programmed with a proprietary telephone (PT). Proprietary telephones available for System Programming are: KX-T7235; KX-T7230; KX-T7 130; and a-T7030 (Display Proprietary Telephones). Two extensions are allowed to perform System Programming. The available extensions are: (1) An extension that is connected to jack 1. (2) An extension that is assigned as a manager. For more information and programming instructions,...
Page 206
SFeatures., System Speed Dialing DescriptionThis feature supports 100 abbreviated dial numbers that are available to all users. A system speed dial number is dialed out by pressing the AUTO button and a 2-digit code (00 through 99). It is possible to store one hundred 24-digit telephone numbers per system (maximum). Conditions. Overriding Toll Restriction for System Speed Dialing can be activated or deactivated by system programming. @?or proprietary telephone users only] l Speed Dialing, One-Touch...
Page 207
FeaturesS System Working Report DescriptionThe Digital Super Hybrid System automatically records the system’s working status condition. A printer connected to the Serial Interface (RS-232C) port can be used to print the recorded data. The recorded data can be printed out by the operator or manager. Recorded contents are as follows: 1. Date of record l The date and time when cleared l The date and time when printed out 2. Incoming calls l The number of incoming calls l The number of answered incoming...
Page 208
SFeatures Programming References Section 4, System Programming [ 1001 Flexible Numbering, System working report [806] Serial Interface (RS-232C) Parameters Feature ReferencesSection 3, Features Station Message Detail Recording (SMDR) Operation ReferencesOperator / Manager Service Features-User Manual System Working Report 3- 148Features
Page 209
3FeaturesTime-out, VariableT DescriptionProvides timers to control various features or functions. The following timers are programmable:System Timer Items Range Automatic Redial Interval Timenx lOs, n:3 - 120 Automatic Redial Repeated Times1 - 30 times Call Forwarding - No Answer Time-Out1 - 12 rings Call Park Recall Time 3 - 48 rings DISA AA Wait Time1-5s DISA Delayed Answer Time0 - 6 rings Extension-to-Outside Call Duration Time1 - 64 min Hold Recall Time0-240s Intercept Routing Time-Out 3 - 48 rings...
Page 210
T3Features ,,,,,Voice Mail Integration Timer Items DTMF Signal Duration DTMF Signal Waiting Time after VPS Answer 80 / 160 ms0.5 / 1.0 / 1.5 / 2.0 s DTMF Signal Waiting Time after VPS calls Extension0.5 / 1.0 / 1.5 / 2.0 s Programming References Section 4, System Programming [200] Hold Recall Time [201] Transfer Recall Time [202] Call Forwarding - No Answer Time [203] Intercept Time [204] Pickup Dial Waiting Time [205] Extension-to-Outside Line Call Duration Time [206] Outside-to-Outside Line Call...