2.7 [1] Configuration PC Programming Manual 71 Feature Manual References 1.19.3 Voice Mail (VM) Group DPT Type—Location No. (for Hybrid port) Specifies the location number of the connected DSS Console. Default 1 Value Range 1–4 Maintenance Console Location 2.7.4 [1-1] Slot—Extension Port Programming Manual References None Feature Manual References None DPT Type—VM Unit No. (for Hybrid port) Selects the unit number of the connected VPS. Default 1 Value Range 1 Maintenance Console Location 2.7.4 [1-1]...
Page 72
2.7 [1] Configuration 72 PC Programming Manual Value Range 1–4 Maintenance Console Location 2.7.4 [1-1] Slot—Extension Port Programming Manual References None Feature Manual References 1.19.3 Voice Mail (VM) Group 2.7.5 [1-1] Slot—Extension Port—Port Command Commands for the extension ports can be programmed. INS Puts the port in service. Default Not applicable. Value Range Not applicable. Maintenance Console Location 2.7.5 [1-1] Slot—Extension Port—Port Command Programming Manual References 2.7.4 [1-1]...
Page 73
2.7 [1] Configuration PC Programming Manual 73 Maintenance Console Location 2.7.5 [1-1] Slot—Extension Port—Port Command Programming Manual References 2.7.4 [1-1] Slot—Extension Port Feature Manual References None 2.7.6 [1-1] Slot—Extension Port—Port Type View Displays the number of connected telephones and Cell Stations (CSs). This screen can only be accessed in Interactive mode. Ty p e Indicates the types of telephone (reference only). Default Not applicable. Value Range APT, SLT, DSS Console, VM,...
Page 74
2.7 [1] Configuration 74 PC Programming Manual Programming Manual References 2.7.4 [1-1] Slot—Extension Port Feature Manual References None 2.7.7 [1-1] Slot—LCO Card Property The properties of the analog CO line cards can be specified. Outgoing Guard Time Specifies the length of time after a CO line is disconnected, during which the PBX cannot seize the line. Default 3 s Value Range 3–6 s Maintenance Console Location 2.7.7 [1-1] Slot—LCO Card Property Programming Manual References None Feature Manual...
Page 75
2.7 [1] Configuration PC Programming Manual 75 Feature Manual References None CO Feed Back Tone Specifies whether the pulse feedback tone is turned on or not. For outgoing CO line calls, audible tones can be heard as the dialed number is sent out, which informs the extension user that the number has been dialed. Default Ye s Value Range No, Yes Maintenance Console Location 2.7.7 [1-1] Slot—LCO Card Property Programming Manual References None Feature Manual References None Bell Detection—Bell Start...
Page 76
2.7 [1] Configuration 76 PC Programming Manual Default 6.0 s Value Range 1.0 s–15.0 s Maintenance Console Location 2.7.7 [1-1] Slot—LCO Card Property Programming Manual References None Feature Manual References None Pulse / DTMF Dial—DTMF Inter-digit Pause Specifies the length of the DTMF inter-digit pause. This allows the telephone company to have enough time to accept the dialed digits correctly. Default 112 ms Value Range 64 + 16 × n (n=0–15) ms Maintenance Console Location 2.7.7 [1-1] Slot—LCO Card...
Page 77
2.7 [1] Configuration PC Programming Manual 77 Programming Manual References None Feature Manual References None Low Speed Pulse Dial—Pulse % Break Specifies the % break for a low speed pulse dial. This is the ratio between the break (on-hook) signal and make (off-hook) signal in a pulse dial. Default 60 % Value Range Other, 60 %, 67 % Maintenance Console Location 2.7.7 [1-1] Slot—LCO Card Property Programming Manual References 2.7.8 [1-1] Slot—LCO Port Feature Manual References None Low Speed Pulse...
Page 78
2.7 [1] Configuration 78 PC Programming Manual Low Speed Pulse Dial—Make Width Specifies the minimum length of the make signal in a low speed pulse dial. Low Speed Pulse Dial— Pulse % Break on this screen determines the value that can be specified here. Default 40 ms Value Range 4 × n (n=3–15) ms Maintenance Console Location 2.7.7 [1-1] Slot—LCO Card Property Programming Manual References 2.7.8 [1-1] Slot—LCO Port Feature Manual References None High Speed Pulse Dial—Pulse % Break Specifies the % break...
Page 79
2.7 [1] Configuration PC Programming Manual 79 Value Range 4 × n (n=4–18) ms Maintenance Console Location 2.7.7 [1-1] Slot—LCO Card Property Programming Manual References 2.7.8 [1-1] Slot—LCO Port Feature Manual References None High Speed Pulse Dial—Make Width Specifies the minimum length of the make signal in a high speed pulse dial. High Speed Pulse Dial— Pulse % Break on this screen determines the value that can be specified here. Default 20 ms Value Range 4 × n (n=3–15) ms Maintenance Console...
Page 80
2.7 [1] Configuration 80 PC Programming Manual Feature Manual References None Option Card Equipment—Option 1 and Option 2 Indicates the type of the card that is installed on the LCOT card (reference only). Default Current option card type Value Range None, Caller ID Card Maintenance Console Location 2.7.7 [1-1] Slot—LCO Card Property Programming Manual References 2.7.8 [1-1] Slot—LCO Port—Caller ID Detection Feature Manual References 1.3.1 Caller ID Caller ID—Caller ID Signalling Selects the type of...