Page 101
2.8 [2] System PC Programming Manual 101 Value Range External BGM, Internal BGM 1, Internal BGM 2 Maintenance Console Location 2.8.3 [2-2] Operator & BGM Programming Manual References None Feature Manual References 1.2.1 BGM (Background Music) BGM and Music on Hold—Music on Hold Selects the audio source for Music on Hold. Default BGM Value Range To n e , B G M Maintenance Console Location 2.8.3 [2-2] Operator & BGM Programming Manual References None Feature Manual References 1.11.4 Music on Hold BGM and...
Page 102
2.8 [2] System 102 PC Programming Manual Feature Manual References 1.3.8 Call Transfer 2.8.4 [2-3] Timers & Counters Various system timers and counters can be programmed. Dial / IRNA / Recall / Tone Dial—Hot Line (Pickup Dial) Start Specifies the length of time between going off-hook and the start of automatic dialing when the Hot Line feature is set. Default 1 s Value Range 0–15 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References...
Page 103
2.8 [2] System PC Programming Manual 103 Feature Manual References 1.1.5 Automatic Extension Release Dial—Extension Inter-digit Specifies the length of time within which subsequent digits must be dialed before the PBX sends a reorder tone. Default 10 s Value Range 0–15 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.1.5 Automatic Extension Release Dial—Analog CO First Digit Specifies the length of time within which the first...
Page 104
2.8 [2] System 104 PC Programming Manual Dial—Analog CO Inter-digit Specifies the length of time within which subsequent digits of a telephone number must be sent to an analog CO line. If no digit is sent before this time expires, the PBX recognizes end of dialing and stops muting the callers voice over the analog CO line. Default 5 s Value Range 1–15 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References None Dial—Analog CO Call...
Page 105
2.8 [2] System PC Programming Manual 105 Value Range 1–240 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.9.9 Intercept Routing Recall—Hold Recall Specifies the length of time until the holding extension receives a Hold Recall ring or alarm tone when a held call remains unretrieved. Default 60 s Value Range 0 (disable the Hold Recall)–240 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual...
Page 106
2.8 [2] System 106 PC Programming Manual 2.10.8 [4-2-1] Portable Station—Extension Settings Feature Manual References 1.3.8 Call Transfer Recall—Call Park Recall Specifies the length of time that a parked call waits to be retrieved, before the Transfer Recall destination assigned to the extension that parked the call hears a Call Park Recall ring. Default 60 s Value Range 1–240 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.10.1 [4-1-1] Wired...
Page 107
2.8 [2] System PC Programming Manual 107 Tone Length—Busy Tone / DND Tone Specifies the length of time that a busy/DND tone is heard when a call is made to an extension in busy status or DND mode. A reorder tone will be sent when this timer expires. (For a call through DISA, the call will be disconnected when this timer expires.) Default 10 s Value Range 0 (continuous)–15 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.4.8 DND...
Page 108
2.8 [2] System 108 PC Programming Manual Value Range 1–15 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.1.5 Automatic Extension Release 1.8.2 Hands-free Operation DISA / Door / Reminder / U. Conf DISA—Delayed Answer Timer Specifies the length of time that the caller hears a ringback tone before hearing an OGM. Default 5 s Value Range 0–30 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual...
Page 109
2.8 [2] System PC Programming Manual 109 Programming Manual References 2.11.4 [5-3-2] Voice Message—DISA Message Feature Manual References 1.4.6 DISA (Direct Inward System Access) DISA—No Dial Intercept Timer Specifies the length of time after the OGM finishes playing in which the caller must begin dialing before the call is redirected to the operator. Default 10 s Value Range 0–120 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.8.3 [2-2] Operator & BGM...
Page 110
2.8 [2] System 110 PC Programming Manual DISA—Intercept Timer—Day, Lunch, Break, Night Specifies the length of time until an unanswered DISA call is intercepted and redirected to the intercept routing destination after the original destination receives the call in each time mode. Default 40 s Value Range 0–60 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.9.1 [3-1-1] Trunk Group—TRG Settings—Intercept—Intercept Destination—Day, Lunch, Break, Night 2.10.1...